Manual
Table Of Contents
- Introduction
- Getting Started
- VCA Feature Packages
- Accessing VCA Configuration
- Activation
- Obtaining an Activation Code
- Applying an Activation Code to a Unit
- Switching VCA On and Off
- Enabling Metadata Streaming
- Configuration of Zones and Rules
- Customizing the Tracking Display
- Creating Detection Zones and Lines
- Creating a Zone or Line
- Non-Detection Zones
- Detection Rules
- Object Presence
- Object Direction
- Object Enter and Exit
- Object Appear and Disappear
- Object Dwell
- Object Stopped
- Object Class
- Object Tailgating
- Object Speed
- Object Color Filter
- Counting Line
- Camera Calibration
- Calibration Page Elements
- Calibrating a Camera
- Advanced Calibration Parameters
- Vertical Field of View
- Measurement Units
- Object Classification
- Logical Rules
- Adding and Removing Logical Rules
- Editing Logical Rule Clauses
- Editing Logical Rule Actions
- Clause Types
- Action Types
- Counters
- Creating Counters
- Assigning Rules to Counters
- Counter Storage and Reporting
- Counter Database Service
- Counter Reporting Service
- Email Notification
- Enable Email Notification
- Adding a New Email Notification Recipient
- Email Configuration
- Name
- Description
- Email Address
- Schedule Configuration
- Current Device Time
- Enable Hourly Report
- Trigger Time
- Weekday
- Enable Daily Report
- Trigger Time
- Weekday
- Enable Weekly Report
- Trigger Day
- Trigger Time
- Enable Monthly Report
- Trigger Day
- Trigger Time
- Report Configuration
- Time
- Report All Data
- Time Range
- Counter ID
- Table (Sampling)
- Sorting Order
- Value Type
- Format
- Send Test Report
- Importing Data into Microsoft Excel
- Other Reports
- Heatmap Reporting
- Events Reporting
- Tracks Reporting
- Tamper Detection
- Scene Change Detection
- Burnt-in Annotation
- PTZ Profiles
- PTZ Control Element
- Configure a PTZ Preset
- Create VCA Profile
- Delete VCA Profile
- Disable PTZ Preset
- PTZ Configuration and Auto-Tracking
- PTZ General Configuration
- PTZ Auto-tracking Configuration
- Importing & Exporting VCA Configuration
- Generating External Event Notifications
- Advanced VCA Settings
- Alarm Holdoff Time
- Measurement Units
- Metadata Format
- Event
- Object
- Counting
- Do not send empty metadata packets
- Blob
- Tamper Diagnostics
- Counting Line Diagnostics
- Scene Change Diagnostics
- More Information
- Stationary Object Hold-on Time
- Tracking Options
- Minimum Tracked Object Size
- Display Options
- Minimum Alarm Object Display Time
- Minimum Object Display Time
- Detection Point of Tracked objects
- People Tracker
05-2018-A
Ganz GXi Series VCA Interface Manual V3.05.31.18
79 | P a g e
Trigger Day
Select the day of the month on which the notification should be sent. If the day of the month is set to "31"
and the current month doesn't have 31 days, the notification will be sent on the last day of the month.
e.g. If the trigger day is set to 31, but the current month is April, the email notification will be sent on April
30th.
Trigger Time
Select the time when the notification should be sent.
e.g. If the trigger day is set to 10 and the trigger time is set to 9:00, then the email notification will be sent
at 9:00 on the 10th day of every month.
Report Configuration
Configures the contents of the notification email.
Time
Selects the time range of the source data for the contents of the report.
Report All Data
Check to include data for the entire day in the report.
Time Range
Configure the time boundaries for the contents of the report.
e.g. If (from) is set to 9:00 and (to) is set to 17:00, then the report will contain count data from 9:00 to
17:00.
Note: if "Enable hourly report" is selected, it's not possible to configure the time boundaries for the report
since hourly reports always report the data from the previous whole hour.
e.g. if the trigger time for an hourly report is configured as 2:00, the report will contain count data from
1:00 to 1:59.