Manual
Table Of Contents
- Introduction
- Getting Started
- VCA Feature Packages
- Accessing VCA Configuration
- Activation
- Obtaining an Activation Code
- Applying an Activation Code to a Unit
- Switching VCA On and Off
- Enabling Metadata Streaming
- Configuration of Zones and Rules
- Customizing the Tracking Display
- Creating Detection Zones and Lines
- Creating a Zone or Line
- Non-Detection Zones
- Detection Rules
- Object Presence
- Object Direction
- Object Enter and Exit
- Object Appear and Disappear
- Object Dwell
- Object Stopped
- Object Class
- Object Tailgating
- Object Speed
- Object Color Filter
- Counting Line
- Camera Calibration
- Calibration Page Elements
- Calibrating a Camera
- Advanced Calibration Parameters
- Vertical Field of View
- Measurement Units
- Object Classification
- Logical Rules
- Adding and Removing Logical Rules
- Editing Logical Rule Clauses
- Editing Logical Rule Actions
- Clause Types
- Action Types
- Counters
- Creating Counters
- Assigning Rules to Counters
- Counter Storage and Reporting
- Counter Database Service
- Counter Reporting Service
- Email Notification
- Enable Email Notification
- Adding a New Email Notification Recipient
- Email Configuration
- Name
- Description
- Email Address
- Schedule Configuration
- Current Device Time
- Enable Hourly Report
- Trigger Time
- Weekday
- Enable Daily Report
- Trigger Time
- Weekday
- Enable Weekly Report
- Trigger Day
- Trigger Time
- Enable Monthly Report
- Trigger Day
- Trigger Time
- Report Configuration
- Time
- Report All Data
- Time Range
- Counter ID
- Table (Sampling)
- Sorting Order
- Value Type
- Format
- Send Test Report
- Importing Data into Microsoft Excel
- Other Reports
- Heatmap Reporting
- Events Reporting
- Tracks Reporting
- Tamper Detection
- Scene Change Detection
- Burnt-in Annotation
- PTZ Profiles
- PTZ Control Element
- Configure a PTZ Preset
- Create VCA Profile
- Delete VCA Profile
- Disable PTZ Preset
- PTZ Configuration and Auto-Tracking
- PTZ General Configuration
- PTZ Auto-tracking Configuration
- Importing & Exporting VCA Configuration
- Generating External Event Notifications
- Advanced VCA Settings
- Alarm Holdoff Time
- Measurement Units
- Metadata Format
- Event
- Object
- Counting
- Do not send empty metadata packets
- Blob
- Tamper Diagnostics
- Counting Line Diagnostics
- Scene Change Diagnostics
- More Information
- Stationary Object Hold-on Time
- Tracking Options
- Minimum Tracked Object Size
- Display Options
- Minimum Alarm Object Display Time
- Minimum Object Display Time
- Detection Point of Tracked objects
- People Tracker
05-2018-A
Ganz GXi Series VCA Interface Manual V3.05.31.18
80 | P a g e
Counter ID
Specifies which counters are included in the report. Can be any one of:
Counter ID
Details
Example
Active
All currently displayed counters
1,4,5,6
All
All counters
0-19
One of 0-19
An individual counter id
1
Table (Sampling)
Select which tables are used as source count data to be included in the report. Multiple selections are
possible.
Sorting Order
Selects the sorting order of the count data. Can be one of:
Sorting order
Details
Descending
The newest records are returned first
Ascending
The oldest records are returned first
Value Type
Specifies the results returned should be absolute counts or the difference between the current and
previous sample. Can be one of:
Value Type
Details
Absolute
The actual counter values are returned
Difference
The difference between this and the previous sample is returned
Format
Selects the format of the contents of the notification email.
Format
Details
Table
Embedded report as HTML table into email
Bar
Embedded report as a bar graph into email
CSV (Attachment)
Attach the report to the email as a csv file
CSV (Plain Text)
Embed the report as plain text into email