GARDENA Dirty Water Pump 6500 SP / 8000 SP / 13000 SP GB Welcome to the garden of GARDENA ... Translation of the original instructions from German. Please read these operating instructions carefully and observe the notes given. Use the instructions to familiarise yourself with the dirty water pump, its correct use, and the notes on safety. For safety reasons, children under 16 as well as persons not familiar with these operating instructions should not use this dirty water pump.
2. For Your Safety According to DIN VDE (German Electrical Engineers’ Association) 0100, dirty water pumps may only be used in swimming pools, garden ponds, and fountains if the pump is operated via a residual-current device with a residual-current rating of ≤ 30 mA. The pump must not be operated when there are persons in the swimming pool or garden pond. For safety reasons we recommend that you always operate the pump via a residual-current device (DIN VDE 0100-702 and 0100-738).
v Clear the outlet line before use. Dry-running operation causes increased wear and is to be avoided. Therefore, in manual operation the pump must be immediately unplugged when water fails to flow. Avoid running of the pump for more than 10 min. against closed delivery side of the pump. Take care that the pump is located where the inlet openings at the suction base are obstructed neither completely nor partly. Stand the pump on a brick if using in a pond.
The universal fitting 7 allows you to connect all the hoses listed in the previous table. 1. Cut off nipples of the universal fitting 7, which are not needed, to match the hose connection. 2. Screw the universal fitting 7 onto the pump. 3. Connect the hose to the universal fitting 7. We recommend that you secure 38 mm (1 1/ 2 ”) and 25 mm (1”) hoses additionally with a GARDENA Hose Clip Art. No. 1591.
1 The pump remains in constant operation because the float switch is bypassed. 1. Push the float switch 5 onto the float switch lock 3 with the cable downward. 2. Stand the pump on a firm surface – or – use a rope attached through the bore hole in the carrying handle 2 to immerse the pump in a well or shaft. 3. Plug the power cable 1 into a mains socket.
Probable cause Remedy Pump doesn’t start or suddenly stops during operation. Thermal overload switch has switched the pump off due to overheating. v Disconnect plug and clean feed impeller (see 5. Cleaning). Observe max. media temperature of 35 °C. No power. v Check fuses and electric connections. Dirt particles are jammed in the suction base. v Disconnect plug and clean suction base (see 5. Cleaning). Suction base is clogged. v Disconnect plug and clean suction base (see 5. Cleaning).
6500 SP (Art. 1792) 8000 SP (Art. 1794) 13000 SP (Art. 1796) Mains voltage / mains frequency 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz Min. cut-in height approx. 200 mm 205 mm 235 mm Min. / max. cut-out height approx. 65 mm / 165 mm 65 mm / 195 mm 65 mm / 225 mm Noise level L WA1) 46 dB (A) 47 dB (A) 50 dB (A) GB Type 1) Measuring method according to EN 60335 -1 Cut-in / Cut-out height The cut-in and cut-out height varies.
GB Product Liability We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories. EU Certificate of Conformity The undersigned GARDENA Manufacturing GmbH Hans-Lorenser-Str.
Deutschland / Germany GARDENA Manufacturing GmbH Service Center Hans-Lorenser-Straße 40 D-89079 Ulm Produktfragen: (+ 49) 731 490 - 123 Reparaturen: (+ 49) 731 490 - 290 service@gardena.com Croatia KLIS d.o.o. Stanciceva 79 10419 Vukovina Phone: (+ 385) 1 622 777 0 gardena@klis-trgovina.hr Cyprus FARMOKIPIKI LTD P.O. Box 7098 74, Digeni Akrita Ave. 1641 Nicosia Phone: (+ 357) 22 75 47 62 Argentina ® condam@spidernet.com.cy Argensem S.A.