INSTALLATION
Connecting the power supply
Take the following into consideration when planning
where to place the power supply:
Close to the charging station
Protection from rain
Protection from direct sunlight
If the power supply is connected to an electrical socket
outdoors, this must be approved for outdoor use.
The low voltage cable for the power supply is 10 metres
long, and may not be shortened or extended.
It is not allowed to connect the power supply directly to
the charging station. The low voltage cable must always
be used.
IMPORTANT INFORMATION
The low voltage cable must not under any
circumstances be shortened or extended.
It is possible to let the low voltage cable cross the
working area. The low voltage cable must be stapled
down or buried.
Make sure the low voltage cable is laid along the ground
and secured with pegs. The cable must lie close to the
ground so as not to be cut before the grass roots have
grown over it.
IMPORTANT INFORMATION
Place the low voltage cable so that the
blades on the blade disc can never come
in contact with it.
The power supply must be placed where it is well
ventilated and is not exposed to direct sunlight. The
power supply must be placed under a roof.
It is recommended to use a ground fault circuit interrupter
when connecting the power supply to the wall socket.
The power supply must be mounted on a vertical surface,
such as a wall or a fence.
3018-069
3018-085
3012-1352