Operation Manual

English - 76
TROUBLESHOOTING
b) Put AL and G1 back in their original positions.
Then switch AR and G1.
If the indicator lamp is lit with a solid green light,
then the break is somewhere on the boundary
wire between AR and the point where the guide
wire is connected to the boundary wire (thick
black line in the illustration).
4. a) Assume that the indicator lamp is lit with a
solid green light in test 3a) above. Reset all
connections to their original positions. Then
disconnect AR. Connect a new loop wire to AR.
Connect the other end of this new loop wire
somewhere at the centre of the installation.
If the indicator lamp is green, then the break is
somewhere in the wire between the disconnected
end to the point where the new wire is connected
(thick black line in the illustration).
Guide
AR
G1
3018-232
3018-233
AR