Operation Manual
Table Of Contents
- Contents
- Introduction
- Safety
- Installation
- Presentation
- Preparations
- Charging station
- Charging the battery
- Boundary wire
- Connecting the boundary wire
- Installation of the guide wire
- Checking the installation
- First start-up and calibration
- Control panel
- Menu structure
- Timer
- SensorControl
- Smart System
- Security
- Installation
- Settings
- Menu structure overview
- Menu structure overview
- Yard layout examples
- Open and level area
- A number of islands and a 35% slope
- L-shaped garden with a couple of islands and the charging station installed in the narrow area
- U-shaped garden linked with a narrow passage
- Unsymmetrical working area with a narrow passage and a number of islands
- 3 areas linked with two narrow passages
- A secondary area
- Operation
- Maintenance
- Troubleshooting
- Transportation, storage and disposal
- Technical data
- Warranty
- EC Declaration of Conformity

Continue until only a very short section of the wire
remains which is the difference between a solid
green light and a flashing blue light. Then follow
instruction in step 5 below.
4. If indicator lamp still flashes blue in step 3
above: Put AL and G1 back in their original
positions. Then switch AR and G1. If indicator lamp
now is lit with a solid green light then disconnect AL
and connect a new boundary wire to AL. Connect
the other end of this new wire at the middle of the
suspected wire section. Follow the same approach
as in 3 a) and 3b) above.
5. When the break is found, the damaged section must
be replaced with a new wire. Always use original
couplers.
50 - Troubleshooting 307 - 002 - 11.10.2017