Specification

600 V max. building wiring
1000 V max. lighting fixtures/
luminaires & signs
Capacidad nominal de
600 V Máx. para cableado
en general, para equipos
de iluminación y letreros
eléctricos a 1000 V Máx.
Fil de bàtiment de 600 V
Max., appareillage électrique
et enseignes de 1000 V Max.
2 - 4 #12
2 - 4 #14
1 #10 + 1 / 2 #12
1 #10 + 1 - 3 #14
1 / 2 #12 + 1 - 3 #14
3 #12 + 1 #14
APPLICATION
Use #95™ GreenGard™ twist-on wire connector in general purpose
applications of 2 or more copper wires in grounding applications. Features
through-hole at end of connector for tying of ground to a single connection.
SPECIFICATIONS
GreenGard™ connectors shall feature wing type shell and steel inner spring
and be suitable for connecting copper wire from #14 to #10 AWG. Shell shall
be green to comply with National Electrical Code requirements and feature a
hole at one end to permit with pass-through. Spring shall be plated to resist
corrosion and have a square profile to provide secure contact with wires.
Connectors shall be rated for use with 600 V building wire / 1000 V lighting
applications plus be UL listed and CSA certified for applications up to 105 °C.
GreenGard™ connectors must have few turns to meet required torque, meet
or exceed UL pull out and dielectric test requirements.
INSTALLATION INSTRUCTIONS
1. Strip wire 1" (25.4 mm). Note: "through" wire must be #12 or #14 AWG and
stripped completely.
2. Pretwisting unnecessary. Hold stripped wires together with ends even.
(Lead stranded wires slightly).
3. Align any frayed strands or conductors.
4. Screw on connector; push wires firmly into connector when starting.
5. To be sold only with installation instructions.
! !
WARNING:
Shut off power before working on a circuit. Use
approved materials and conform to all electrical codes.
CONSTRUCTION
Shell: Polypropylene, Color - Green
Innerspring: Zinc plated, square profile steel wire
Temperature Rating: 105 °C (221 °F)
WIRE RANGE
#14 to #10 AWG Solid or Stranded conductors
Copper conductors only, 600 V max. building wire;
1000 V max. for lighting fixtures and luminaries/signs
REGULATORY APPROVALS
UL: List for pressure type wire connectors per UL 486C,
file number 61X5. UL94V-2 flame retardant.
GreenGard™
Electrical Wire Connector
#95™ (Green)
Wire Connector
61X5
DATA SHEET / HOJA DE DATOS / FICHE TECHNIQUE
#95™ GreenGard™
DS-0013
Gardner Bender l Milwaukee, WI 53209 l www.gardnerbender.com l Questions or Comments 800.624.4320
Made in China/Hecho en China/Fabriqué en Chine l ZX436
WIRE COMBINATIONS / COMBINACIONES
DE CABLE / COMBINAISONS DE CABLES
LISTED FOR USE WITH: COPPER TO COPPER
Temperature rating: 105 °C (221 °F) Listed as a
PRESSURE TYPE wire connector for the following
solid and/or stranded wire connections:
CLASIFICADO PARA USARSE CON:
COBRE A COBRE
Especificatión de temperatura: 105 °C (221 °F)
Clasificado como un conector de cable TIPO A
PRESION para uso con las siguientes conexiones
de cable macizo y/o trenzado:
POUR USAGE DE: CUIVRE A CUIVRE
Cote de température: 105 °C (221 °F) Connecteur
A PRESSION pour les combinaisons suivantes de
fils pleins et/ou à brins:
A B C D E
#95™
(in) 1-5/32 5/16 9/32 7/16 29/32
(mm) 29.4 7.9 7.1 11.1 23
DIMENSIONS

Summary of content (2 pages)