User's Manual

GTS Processor Installation Manual Page 3-11
190-00587-50 Revision A
Normal System Mode Tab
The Normal Tab displays various faults, flags, and operational information. When the Normal Tab is
selected, the unit is commanded to Normal System Mode. ‘Alpha Values’ phase measurement values for
the Top Antenna and Bottom Antenna (if a bottom directional antenna is installed) are found on the GTS
Processor Install Tool Normal tab, and are updated only after a self-test (Section 3.8.5) is run. These
antenna phase measurements are used to determine if the installation has adequate antenna ground planes.
Figure 3-12 GTS Processor Install Tool – Normal Tab
Normal Mode –
System Faults:
Red Bold text indicates that a fault is active.
Gray text indicates that there is no active fault.
(System Faults are described in the Calibration/Self-Test Section 3.8.5)
Status Flags:
Black Bold text indicates that a flag is set.
Gray text indicates that the flag is not set.
(Status Flags are described in the Calibration/Self-Test Section 3.8.5)
Ground Test:
Enabled
Disabled
(Ground Test is described in the Ramp Test and Return to Service Tests Section 3.8.6).