Installation Instructions

190-01007-A3 GTN 6XX/7XX AML STC Installation Manual
Rev. 4 Page 5-37
5.5.2.2 Charts (GTN 7XX Only)
The GTN 7XX can display Jeppesen charts using the optional ChartView feature, which must be
activated. To configure which Charts to display, touch either None, FliteCharts, or ChartView. If
ChartView is selected, it must be enabled as described below.
NOTE
The ChartView Enablement Card can only
be used on one GTN (for dual GTN
installations a separate ChartView
Enablement Card must be used on each
GTN).
1. Turn the GTN off by pulling the circuit breaker.
2. Remove the database SD card from the SD card slot
and insert a ChartView Enablement Card, P/N 010-
00878-40.
3. Enter configuration mode on the GTN by applying
power to the GTN (closing the circuit breaker) while
holding the HOME key.
4. Go to the Charts page from the GTN Options page. Touch the ChartView key.
5. When prompted, touch Yes to enable ChartView.
6. When the ChartView feature is activated, the ChartView
key will be lit green, as shown in
Figure 5-22.
NOTE
Navigation or chart data must not be programmed on the ChartView Enablement Card.
Figure 5-22. Chart
Configuration Page