Installation Instructions

GTN 6XX/7XX AML STC Installation Manual 190-01007-A3
Page 5-78 Rev. 4
5.5.4.9.7.8 RS-232 Inputs
The RS-232 Inputs diagnostics page allows the display of serial data that is being received and is useful
for determining if the GDL 88 is receiving data on each connected port. To access this page, touch
External Systems
GDL 88 Diagnostics RS232 Inputs. Select the desired port by touching the
Port key and selecting the RS-232 channel from the list. The data log can be paused by toggling the
Pause key. Clear the data log by touching Clear Log.
5.5.4.9.7.9 ARINC Inputs
The ARINC Inputs diagnostics page allows the display of ARINC 429 data that is being received over
each GDL 88 ARINC 429 port. To access this page, touch External Systems
GDL 88 Diagnostics
ARINC inputs. Each port can be chosen for display by touching the Port key and toggling between
the input ports. Select a port to display. The GTN will then display the label, SSM, Data, and SDI for
each GDL 88 ARINC 429 input port. This is useful for determining if the expected labels are being
received and also for troubleshooting incorrect or swapped wiring to the input ports. The data log can be
paused by toggling the Pause key. Clear the data log by touching Clear Log.
5.5.4.9.7.10 HSDB (Ethernet)
The HSDB (Ethernet) diagnostics page allows the status of each HSDB port to be displayed. To access
this page, touch External Systems
GDL 88 Diagnostics HSDB (Ethernet). This page displays
whether or not each port is receiving data and displays whether the port is connected or not connected.
The configuration status of each installed HSDB LRU is also displayed.
5.5.4.10 GSR 56 Configuration
If the GSR 56 Iridium transceiver is installed and connected to the GTN, the GSR 56 features that will be
used must be enabled.
1. Go to the GSR 56 page in the External Systems page group.
2. Touch on the desired features to be activated. When active, the key for the feature will be lit
green.
3. Ensure that the RUDICS Number setting is 0088160000576. If the RUDICS Number setting is
incorrect, touch Restore Defaults.
4. Ensure that the SMS SCA setting is 881662900005. If the SMS SCA setting is incorrect, touch
Restore Defaults.
5.5.4.11 Weather Radar Configuration (GTN 7XX Only)
5.5.4.11.1 GWX 68/70 Configuration
To configure the GWX 68/70, it must first be selected as present and the model of GWX installed must be
specified. To do this, see Section 5.5.1.4. Next, go to the External Systems page and touch the Weather
Radar key.
5.5.4.11.1.1 GWX Configuration Settings
Pitch Trim
This setting specifies the offset angle being used by the GWX for the pitch axis. Selections: -4.00° to
+4.00° in 0.01° increments.
Roll Trim
This setting specifies the offset angle being used by the GWX for the roll axis. Selections: -4.00° to
+4.00° in 0.01° increments.