Installation Instructions
190-01007-A3 GTN 6XX/7XX AML STC Installation Manual
Rev. 4 Page 5-83
5.6 Ground Checks (Configuration Mode)
The following checks are done in Configuration Mode. For instructions on entering Configuration Mode,
see Section 5.5.
5.6.1 Main Indicator Check (Analog Only)
NOTE
If the GTN is interfaced to an electronic HSI/EFIS and the main indicator analog output
is not used, this check is not required.
If the GTN is interfaced to an analog indicator on the main CDI/OBS (P1001), perform the following
steps:
1. Go to the GTN Diagnostics page. See Section 5.5.3.
2. Go to the Main Indicator (Analog) page.
3. Verify correct operation of the lateral deviation, flag and TO/FROM flag using the corresponding
selections.
4. Verify correct operation of the vertical deviation and flag using the corresponding selections.
5. Verify correct operation of the OBS knob using the OBS Resolver Setting display. At 30°
increments around the OBS card, ensure that the indicated value is within 2° of the value set on
the indicator. If the resolver is not within 2°, calibrate the resolver as described in Section 5.5.1.5.
5.6.2 VOR/LOC/GS Indicator (GTN 650/750 Only)
If the GTN is interfaced to an analog indicator on the VOR/ILS Indicator output (P1004), perform the
following steps:
1. Go to the GTN Diagnostics page.
2. Go to the VOR/ILS Indicator diagnostics page.
3. Verify correct operation of the lateral deviation, flag and TO/FROM flag using the corresponding
selections.
4. Verify correct operation of the vertical deviation and flag using the corresponding selections.
5. Verify correct operation of the OBS knob using the Selected Course display. At 30° increments
around the OBS card, ensure that the indicated value is within 2° of the value set on the indicator.
If the resolver is not within 2°, calibrate the resolver as described in Section 5.5.1.11.
4.