Installation Instructions
GTN 6XX/7XX AML STC Installation Manual 190-01007-A3
Page B-4 Rev. 4
Figure B-2. GTN 6XX/7XX Mounting Rack Plate Support
Ensure support of forward end of
installation by securing mounting
brackets together using a plate
(shown), bracket, links, or similar
method. A minimum of two
fastener locations is required to
be utilized per mounting rack.
Use existing avionics mounting rails for the attachment to
instrument panel. Existing mounting rails must be electrically
grounded to the instrument panel. The rail surface that
touches the GTN 6XX or GTN 7XX racks need to be cleaned
and prepped for electrical bond. See Section 2.4.4.4 for
electrical bonding guidance.