Installation Instructions
190-01007-A3 GTN 6XX/7XX AML STC Installation Manual
Rev. 4 Page C-3
C.3 Altitude Serializer or Fuel/Air Data
Altitude serializers/encoders not listed below can still be approved under this GTN AML STC if all of the
following conditions are met:
• The altitude serializer/encoder is TSO approved;
• The installation of the altitude serializer/encoder was previously FAA-approved;
• The interface check for the altitude serializer/encoder described in Section 5.6.10 must be
successfully completed.
• The connections to the GTN must utilize shielding wiring of the type specified in this manual.
Shields must be terminated on the GTN side to connector shield block ground and on the Altitude
Serializer or Fuel/Air Data installation data. If the Altitude Serializer or Fuel/Air Data installation
data does not specify a shielding method then terminate the shield at the Altitude Serializer or
Fuel/Air Data using the guidelines provided in Section 2.4.11.4.
Table C-3. Compatible Altitude Serializer or Fuel/Air Data Models
Mfg Model Data Format Configuration
ACK Technologies A-30 (Mod 8 and above) RS-232 Altitude Format 1
ARNAV
FC-10 RS-232 Fuel Format 1
FT-10 RS-232 Fuel Format 1
Electronics International FP-5L RS-232 Fuel Format 1
Garmin GTX 327 RS-232 Altitude Format 1
Icarus Instruments 3000 RS-232 Altitude Format 1
JP Instruments EDM-700 RS-232 Fuel Format 2
Sandia SAE 5-35 RS-232 Altitude Format 1
Shadin
8800T RS-232 Altitude Format 3
9000T [1] RS-232 Altitude Format 3
9200T [1] RS-232 Altitude Format 3
F/ADC-200 RS-232 Airdata Format 1
F/ADC-2000 RS-232 Airdata Format 1
91204XT(38)D (Miniflo-L) RS-232 Fuel Format 2
91053XP (Digiflo-L) RS-232 Fuel Format 2
91053XT-D (Digiflo-L) RS-232 Fuel Format 2
912802-( ) (Digidata) RS-232 Fuel Format 2
Trans-Cal Industries
IA-RS232-X RS-232 Altitude Format 1
SSD120 RS-232 Altitude Format 1
[1] This source must not be connected to the GTN if the GTN is the pressure altitude source
for a Mode S transponder.