Installation Instructions

GTN 6XX/7XX AML STC Installation Manual 190-01007-A3
Page E-5 Rev. 4
NOTES:
1. SEE DETAIL DRAWINGS FOR WIRE GAUGE INFO
2. GROUND DESIGNATIONS
:
SHIELD BLOCK GROUND AIRFRAME GROUND
3.
AT GTN
6XX/7XX, CONNECT SHIELD GROUNDS TO THE CONNECTOR BACKSHELL --
THE SHIELD TERMINATION LEADS MUST BE
LESS THAN 3.0". CONNECT OTHER END OF THE SHIELD PER THE REMOTE EQUIPMENT INSTALLATION REQUIREMENTS. IF NO
SHIELD TERMINATION REQUIREMENT EXISTS FOR THE REMOTE EQUIPMENT
,
TERMINATE SHIELDS AS SHORT AS POSSIBLE
,
NOT TO EXCEED 3
.0
".
SEE SECTION 2.4.11.4.
4
.
THIS DIAGRAM PROVIDES AN OVERVIEW OF A TYPICAL GTN
6XX/7XX INSTALLATION.
REFER TO APPROPRIATE INTERCONNECT
DIAGRAMS FOR SPECIFIC EQUIPMENT.
5. AIRCRAFT POWER INPUT TO THE MAIN,
COM,
AND NAV BOARDS MUST BE
11-33 VDC.
6. THE GMA 35 CAN ONLY BE INTERFACED AND CONTROLLED WITH THE GTN 7
XX.
FOR GTN 6XX INSTALLATIONS, USE AN
ALTERNATE AUDIO PANEL.
7
.
REFER TO FIGURE E-4 FOR POWER AND GROUND WIRING DETAILS
.
8.
CONFIGURATION MODULE HARNESS USES
28 AWG WIRES. CONTACTS SUPPLIED WITH CONFIGURATION MODULE MUST BE
USED FOR CONNECTING CONFIGURATION MODULE HARNESS TO P
1001.
9
.
CONFIGURATION MODULE IS MOUNTED IN THE BACKSHELL OF THE P
1001 CONNECTOR.
10. VERIFY AIRCRAFT GROUND MEETS BONDING REQUIREMENTS IN SECTION 2.4.5.
s
Figure E-2. GTN 650-750 Typical Installation Interconnect
Sheet 2 of 2