Installation Instructions

GTN 6XX/7XX AML STC Installation Manual 190-01007-A3
Page E-11 Rev. 4
NOTES:
1. ALL WIRES 24 AWG OR LARGER UNLESS OTHERWISE SPECIFIED.
2. GROUND DESIGNATIONS: SHIELD BLOCK GROUND AIRFRAME GROUND
3. AT GTN 6XX/7XX, CONNECT SHIELD GROUNDS TO THE CONNECTOR BACKSHELL -- THE SHIELD TERMINATION LEADS
MUST BE LESS THAN 3.0". CONNECT OTHER END OF THE SHIELD PER THE REMOTE EQUIPMENT INSTALLATION
REQUIREMENTS. IF NO SHIELD TERMINATION REQUIREMENT EXISTS FOR THE REMOTE EQUIPMENT, TERMINATE
SHIELDS AS SHORT AS POSSIBLE, NOT TO EXCEED 3.0". SEE SECTION 2.4.11.4.
4. IF THE ARINC 429 IN 1 PORT (P1001 PINS -48 AND -67) IS ALREADY IN USE FOR ANOTHER PURPOSE, ANY AVAILABLE
ARINC 429 IN PORT MAY BE CONNECTED INSTEAD.
5. REFER TO MANUFACTURER’S DOCUMENTATION FOR COMPLETE PINOUT AND INTERCONNECT INFORMATION. PINOUTS
OF OTHER UNITS SHOWN FOR REFERENCE ONLY.
6. THESE OUTPUTS ARE USED ON THE GTN 650/750 ONLY.
7. REFER TO SECTION 5.5.1 FOR CONFIGURATION INFORMATION.
8. TERMINATE SHIELDS AT PFD/MFD IN ACCORDANCE WITH MANUFACTURER’S DOCUMENTATION.
9. DISPLAY P/N 700-00007-( ) WITH SOFTWARE P/N 530-00193-( ) OR LATER IS REQUIRED FOR PROPER OPERATION WITH
THE GTN 6XX/7XX UNIT.
EX500 MFD GPS/FMS SETUP: RECEIVER 1: GAMA 429 FORMAT
PORT: ARINC 429 1 – GPS A DEFAULT
SPEED: LOW
RECEIVER 2: GAMA 429 FORMAT
PORT: ARINC 429 4
SPEED: LOW
10. DISPLAY P/N 700-00004-( ) OR P/N 700-00030-( ) WITH SOFTWARE P/N 530-00195-( ) OR LATER IS REQUIRED FOR PROPER
OPERATION WITH THE GTN 6XX/7XX UNIT.
EX5000 MFD GPS/FMS SETUP: RECEIVER 1: GAMA 429 FORMAT
PORT: ARINC 429 1
SPEED: LOW
RECEIVER 2: GAMA 429 FORMAT
PORT: ARINC 429 4
SPEED: LOW
11. DISPLAY P/N 700-00006-( ) WITH SOFTWARE P/N 530-00194-( ) OR LATER IS REQUIRED FOR PROPER OPERATION WITH
THE GTN 6XX/7XX UNIT.
EXP5000 PFD SETUP: GPS 1: GARMIN 430/530 ON ARINC 1
GPS 2: GARMIN 430/530 ON ARINC 3
VHF 1: GARMIN 430/530 ON ARINC 2
VHF 2: GARMIN 430/530 ON ARINC 4
12. ALL CONNECTIONS TO THE AVIDYNE EXP 5000 PFD MUST BE OVERBRAIDED PER THE AVIDYNE EXP 5000
INSTALLATION MANUAL. USE OVERBRAID P/N AND METHOD OUTLINED IN THE AVIDYNE EXP 5000 INSTALLATION
MANUAL. CONNECTIONS TO THE EX 500/5000 MFD DO NOT NEED TO BE OVERBRAIDED.
13. THE SPLICE MUST BE PERFORMED AT THE GTN CONNECTOR END OF THE WIRE. SPLICE AS SHOWN:
14. MAPMX IS THE PREFERRED COMMUNICATION PROTOCOL FOR THE MX20/GMX 200. OTHER INPUT PORTS ON THE MX20/
GMX 200 MAY BE USED IN LIEU OF THE PORT SHOWN. REFER TO THE APPROPRIATE INSTALLATION MANUAL FOR
ADDITIONAL DETAILS.
s
P100X
s
s
GTN
Figure E-5. GTN 6XX/7XX PFD/MFD Interconnect
Sheet 2 of 2