Installation Instructions

190-01007-A3 GTN 6XX/7XX AML STC Installation Manual
Rev. 4 Page E-33
NOTES:
1. ALL WIRES 24 AWG OR LARGER UNLESS OTHERWISE SPECIFIED.
2. GROUND DESIGNATIONS: SHIELD BLOCK GROUND AIRFRAME GROUND
3. AT THE GTN 6XX/7XX, CONNECT SHIELD GROUNDS TO THE CONNECTOR BACKSHELL
--
THE SHIELD LEADS
MUST BE LESS THAN
3.
0".
CONNECT OTHER SHIELD GROUNDS TO AIRCRAFT CHASSIS WITH AS SHORT A
CONDUCTOR AS PRACTICAL.
4. ONLY ONE TRAFFIC SOURCE MAY BE CONNECTED TO THE GTN. IN DUAL GTN INSTALLATIONS, THE TRAFFIC
SOURCE SHOULD BE CONNECTED TO EACH GTN ON WHICH TRAFFIC IS TO BE DISPLAYED.
5. REFER TO SECTION 5.5.1.1 AND 5.5.1.2 FOR GTN 6XX/7XX CONFIGURATION SETUP.
6. SOFTWARE VERSION 1
.6 OR HIGHER REQUIRED FOR THE TRC 497.
7. THESE OPTIONAL DISCRETE CONNECTIONS ARE NOT REQUIRED IF THE GTN 6
XX
/7
XX IS CONFIGURED FOR
‘GTN CONTROL OF TRAFFIC SYSTEM=NO’. IN THIS CASE, THE GTN 6XX/7XX WILL ONLY BE A TRAFFIC DISPLAY
AND WILL NOT CONTROL THE TRAFFIC ADVISORY SYSTEM OPERATION. SEE SECTION 5.5.1.8 FOR THIS
SETTING.
8. FOR HONEYWELL TRAFFIC SYSTEMS THE “FUNCTIONAL TEST” AND “STBY/OPERATE” DISCRETE INPUTS TO
THE TRAFFIC COMPUTER MUST BE CONNECTED TO ONE DISPLAY ONLY.
9. REFER TO MANUFACTURER’S DOCUMENTATION FOR COMPLETE PINOUT AND INTERCONNECT INFORMATION.
PINOUTS OF OTHER UNITS SHOWN FOR REFERENCE ONLY.
s
10. USE AIRCRAFT GRADE CATEGORY 5 ETHERNET CABLE. THIS INCLUDES THE FOLLOWING:
P/N
10424 (24 AWG)
392404 (24 AWG)
MANUFACTURER
PIC WIRE AND CABLE
CARLISLEIT
11. FOR NEW RYAN 9900BX INSTALLATIONS, IT IS RECOMMENDED TO USE THE RS-232 INTERFACE.
WHEN
INTERFACING THE GTN TO THE RYAN
9900BX VIA ARINC 429, THE ‘GTN CONTROL OF TRAFFIC SYSTEM’
CONFIGURATION SETTING MUST BE SET TO ‘NO’. THE RYAN 9900BX DOES NOT INCLUDE THE NECESSARY
DISCRETE INPUTS TO CONTROL THE TRAFFIC SYSTEM MODE.
12. THE RYAN TCAD PROCESSOR SWITCH PIN (P1-16) SHOULD BE GROUNDED TO TURN THE PROCESSOR UNIT
ON, AND OPEN TO TURN THIS UNIT OFF
. IF A RYAN TCAD DISPLAY UNIT IS NOT IN THE INSTALLATION, A
DEDICATED SWITCH MAY BE REQUIRED TO TURN THE TCAD PROCESSOR UNIT ON AND OFF. REFER TO THE
9900BX INSTALLATION MANUAL P/N 32-2351 FOR ADDITIONAL INFORMATION.
13. IF THESE RS-232 PORTS ARE ALREADY USED FOR ANOTHER PURPOSE, ANY RS-232 PORT MAY BE
CONNECTED IN LIEU OF THESE PORTS
. REFER TO SECTION 5.5.1.2 FOR RS-232 SETTINGS
.
14. REFER TO FIGURE E-12 FOR ADDITIONAL TRANSPONDER CONNECTION INFORMATION.
15. FOR GTN SOFTWARE VERSION 2.
00,
THESE HSDB WIRES SHOULD NOT BE CONNECTED TO THE GTN.
Figure E-13. GTN 6XX/7XX Traffic Sources Interconnect
Sheet 3 of 3