Installation Instructions

GTN 6XX/7XX AML STC Installation Manual 190-01007-A3
Page E-62 Rev. 4
NOTES:
1.
ALL WIRES 24 AWG OR LARGER UNLESS OTHERWISE SPECIFIED
.
2
. GROUND DESIGNATIONS: SHIELD BLOCK GROUND AIRFRAME GROUND
3. AT GTN
6XX/
7XX, CONNECT SHIELD GROUNDS TO THE CONNECTOR BACKSHELL --
THE
SHIELD TERMINATION LEADS MUST BE LESS THAN
3.0
". CONNECT OTHER END OF THE
SHIELD PER THE REMOTE EQUIPMENT INSTALLATION REQUIREMENTS
. IF NO SHIELD
TERMINATION REQUIREMENT EXISTS FOR THE REMOTE EQUIPMENT, TERMINATE SHIELDS
AS SHORT AS POSSIBLE,
NOT TO EXCEED 3.0". SEE SECTION 2.
11.4
.
4. IF THE ARINC 429 IN 1 PORT (P1001 -48 AND -67) IS ALREADY USED FOR ANOTHER PURPOSE,
ANY AVAILABLE ARINC 429 IN PORT MAY BE CONNECTED INSTEAD. REFER TO SECTION 4
FOR PINOUT INFORMATION.
5. REFER TO MANUFACTURER’S DOCUMENTATION FOR COMPLETE PINOUT AND
INTERCONNECT INFORMATION. PINOUTS OF OTHER UNITS SHOWN FOR REFERENCE ONLY.
6. AUTOPILOT SHOWN FOR REFERENCE ONLY. REFER TO THE APPROPRIATE AUTOPILOT
INTERCONNECT DIAGRAM.
7. REFER TO SECTION 5.5.1.1 FOR GTN 6XX/7XX CONFIGURATION SETTINGS.
8. SANDEL SN3500 SETUP ITEMS:
LNAV 1/2 SELECT: GNS 530 (ARINC) ANNUN: SERIAL
LAT DV: SERIAL
VERT DV: SERIAL
VERT ENA: SERIAL
NAV/ILS/DME-1/2: NAV TYPE: 429 TO
s
GTN 6XX/7XX
24VOR/ILS ARINC 429 OUT A
23VOR/ILS ARINC 429 OUT B
48ARINC 429 IN 1A
67ARINC 429 IN 1B
10ARINC 429 OUT 1A
29ARINC 429 OUT 1B
4
P1001
P1004
MAIN VERTICAL +UP OUT
MAIN VERTICAL +DOWN OUT
MAIN VERTICAL +FLAG OUT
MAIN VERTICAL -FLAG OUT
MAIN LATERAL +LEFT OUT
MAIN LATERAL +RIGHT OUT
MAIN LATERAL +FLAG OUT
MAIN LATERAL -FLAG OUT
ILS/GPS APPROACH
12
31
51
70
49
68
50
69
56
7
s
s
s
s
s
s
s
ARINC 429 EHSI
DISPLAY
3/(35)
NAV 429 IN PORT A 1/(2)
33/(21)
30
15
31/(2)
17/(32)
Sandel
SN3500
P2
8
429 OUT A
GPS 429 IN PORT A 1/(2)
NAV 429 IN PORT B 1/(2)
429 OUT B
GPS 429 IN PORT B 1/(2)
+UP
+DOWN
VERTICAL +FLAG
VERTICAL -FLAG
+LEFT
+RIGHT
LATERAL +FLAG
LATERAL -FLAG
Autopilot
LOCALIZER ENGAGE
6
Figure E-25. GTN 6XX/7XX – Sandel SN3500 Interconnect