Installation Instructions
190-01007-A3 GTN 6XX/7XX AML STC Installation Manual
Rev. 4 Page E-89
DUAL GTNS AND GDL 88
P1002
GTN 6XX/7XX
#1
24
23
26
25
ETHERNET IN 3
A
B
ETHERNET OUT 3
A
B
A
B
ETHERNET OUT 1
A
B
ETHERNET IN 1
54
53
52
51
P881
GDL 88/D
S
P1001
22
3
3
22TIME MARK OUT A
TIME MARK OUT B
TIME MARK
1A
TIME MARK 1B
S
P1002
GTN 6XX
/7XX
#2
23
24
25
26
ETHERNET IN 3
B
A
ETHERNET OUT 3
B
A
P1001
22
3
9
28TIME MARK OUT A
TIME MARK OUT B
TIME MARK 2A
TIME MARK 2B
S
3
TO EXISTING
AIRCRAFT WIRING
S
3
TO EXISTING
AIRCRAFT WIRING
S
4
4
35 37
TAWS AUDIO ACTIVE OUT* AUDIO INHIBIT #1*
(GTN 6XX/7XX TAWS UNITS ONLY)
14
13
5
4
ETHERNET IN 4
A
B
ETHERNET OUT 4
A
B
4
SYSTEM ID PROGRAM* 10
5
5
6
6
S
S
S
S
S
1.
ALL WIRES 24 AWG OR LARGER UNLESS OTHERWISE SPECIFIED.
2
. GROUND DESIGNATIONS:
SHIELD BLOCK GROUND AIRFRAME GROUND
3
. IF GTN TIME MARK OUTPUT IS ALREADY CONNECTED TO AIRCRAFT WIRING, SPLICE INTO THIS
WIRING FOR THE CONNECTION TO THE GDL 88.
4
. IF ETHERNET PORT IS ALREADY USED FOR ANOTHER PURPOSE, ANY ETHERNET PORT MAY BE
CONNECTED. REFER TO SECTION
4 FOR PINOUT INFORMATION.
5.
CONNECTION MAY BE MADE TO GTN 6XX/7XX
#2 IN LIEU OF GTN 6XX
/7XX #1
.
6
. USE AIRCRAFT GRADE CATEGORY 5 ETHERNET CABLE.
THIS INCLUDES THE FOLLOWING:
NOTES:
s
P/N
10424 (24 AWG)
392404 (24 AWG
)
MANUFACTURER
PIC WIRE AND CABLE
C
ARLISLE
IT
Figure E-40. GTN 6XX/7XX – GDL 88/88D Interconnect