G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air Page 5-5
190-00716-01 Revision 3
The applicable data paths can be verified by viewing the following configuration mode pages.
5.2.1.1 GDU RS-232 / ARINC 429 CONFIG Page
PFD 1 RS-232
Channel LRU Indicator Status
CHNL 2 GMC 710
Green
PFD1/GMC 710 data path is functioning correctly.
Red
PFD1/GMC 710 data path is not functioning correctly.
Verify GMC710 is powered on.
o If GMC 710 will not power on, remove unit and
verify power and ground are present at the GMC
connector.
If power or ground is not present,
troubleshoot aircraft wiring for faults.
If power and ground are present, replace
GMC 710.
Load PFD1 and GMC 710 configuration files.
Swap PFD1and PFD2 to confirm if the problem is in the
original PFD1.
o Replace original PFD1 if box turns green after
swapping displays.
Check the PFD1/GMC 710 interconnect wiring for faults.
Replace GMC 710 if problem remains.
Amber
PFD1/GMC 710 data path functionality is unknown. Reload
PFD1 configuration file.