Instruction Manual

Page 5-8 G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air
Revision 3 190-00716-01
PFD 2 ARINC 429
Channel LRU Indicator Status
IN 1 GRS 77 #2
Green
PFD2/GRS 77 #2 data path is functioning correctly.
Red
PFD2/GRS 77 #2 data path is not functioning correctly.
Verify GRS77 #2 status is “OK” using the System Status
page on the MFD. If it is not, correct condition before
proceeding, reference GRS troubleshooting sections.
o Swap GRS1 and GRS2 (no reconfiguration
required) to confirm if the problem is in the original
GRS1.
o Replace original GRS1 if box turns green after
swapping units.
Load PFD2 configuration file.
Swap PFD2 and PFD1 to confirm if the problem is in the
original PFD2.
o Replace original PFD2 if box turns green after
swapping displays.
Swap GRS1 and GRS2 (no reconfiguration required) to
confirm if the problem is in the original GRS1.
o Replace original GRS1 if box turns green after
swapping units.
Check the PFD2/GRS 77 #2 interconnect wiring for faults.
Amber
PFD2/GRS 77 #2 data path functionality is unknown. Reload
PFD2 configuration file.
IN 2
GDC 7400
#2
Green
PFD2/GDC 7400 #2 data path is functioning correctly.
Red
PFD2/GDC 7400 #2 data path is not functioning correctly.
Verify GDC 74 #2 status is “OK” using the System Status
page on the MFD. If it is not, correct condition before
proceeding, reference GDC troubleshooting sections.
Load PFD2 and GDC 7400 #2 configuration files.
Swap PFD2 and PFD1 to confirm if the problem is in the
original PFD2.
o Replace original PFD2 if box turns green after
swapping displays.
Check the PFD2/GDC 7400 #2 interconnect wiring for
faults.
Replace GDC 7400 #2 if problem remains.
Amber
PFD2/GDC 7400 #2 data path functionality is unknown. Reload
PFD2 configuration file.