G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air Page 5-15
190-00716-01 Revision 3
GIA2 ARINC 429
Channel LRU Indicator Status
IN 5
GDC 7400
#2
Green
GIA2/GDC 7400 #2 data path is functioning correctly.
Red
GIA2/GDC 7400 #2 data path is not functioning correctly.
Load GIA2 and GDC 7400 #2 configuration files.
Swap GIA2 and GIA1, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA2.
o Replace original GIA2 if box turns green after
swapping units.
Check the GIA2/GDC 7400 #2 interconnect wiring for
faults.
Replace GDC 7400 #2 if problem remains.
Amber
GIA2/GDC 7400 #2 data path functionality is unknown. Reload
GIA2 configuration files.
IN 6 GRS 77 #2
Green
GIA2/GRS 77 #2 data path is functioning correctly.
Red
GIA2/GRS 77 #2 data path is not functioning correctly.
Load GIA2 configuration files.
Swap GIA2 and GIA1, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA2.
o Replace original GIA2 if box turns green after
swapping units.
Swap GRS2 and GRS1 (no reconfiguration required) to
confirm if the problem is in the original GRS2.
o Replace original GRS2 if box turns green after
swapping units.
Check the GIA2/GRS 77 #2 interconnect wiring for faults.
Amber
GIA2/GRS 77 #2 data path functionality is unknown. Reload
GIA2 configuration files.