5.2.2 System Failure Troubleshooting
The following table provides basic troubleshooting guidance for LRU failures. Refer to G1000/GFC 700
Wiring Diagram, listed in Table 1-2, as needed to verify interconnects.
Invalid Data Field
Associated
LRU(s)
Solution
Low Speed Awareness Band
permanently displayed
GDU
With aircraft weight on wheels and the G1000 in
Configuration Mode, check that the RH GEAR ON
GROUND Discrete In indication for GIA2, on GIA I/O
CONFIGURATION page is illuminated.
With aircraft weight on wheels and the G1000 in
Configuration Mode, check that the LH GEAR ON
GROUND Discrete In indication for GIA1, on GIA I/O
CONFIGURATION page is illuminated.
If both indications are illuminated Green, switch GIA1
and GIA2, to verify location of problem:
9 If problem is resolved, replace defective unit.
9 If indication is not illuminated, check for wiring
faults between the GIAs and aircraft squat switch
system.
Low Speed Awareness Band
permanently inhibited
GDU
With aircraft weight on wheels and the G1000 in
Configuration Mode, check that the RH GEAR ON
GROUND Discrete In indication for GIA2, on GIA I/O
CONFIGURATION page is illuminated.
With aircraft weight on wheels and the G1000 in
Configuration Mode, check that the LH GEAR ON
GROUND Discrete In indication for GIA1, on GIA I/O
CONFIGURATION page is illuminated.
If both indications are illuminated Green, switch GIA1
and GIA2, to verify location of problem:
9 If problem is resolved, replace defective unit.
9 If indication is not illuminated, check for wiring
faults between the GIAs and aircraft squat switch
system.
NAV1 & COM1
GIA1
Check configuration settings for GIA1 and PFD1.
Swap GIA1 and GIA2, to verify location of problem:
9 If problem follows GIA1, replace GIA1.
Check Ethernet interconnect from GIA1 to PFD1.
9 If problem persists, replace PFD.
NAV2 & COM2
GIA2
Check configuration settings for GIA2 and PFD2.
Swap GIA1 and GIA2, to verify location of problem:
9 If problem follows GIA2, replace GIA2.
Check Ethernet interconnect from GIA2 to PFD2.