System Maintenance Manual

G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air Page 5-65
190-00682-01 Revision F
5.11.6 GIA Configuration Alerts
Failure Message Cause Solution
MANIFEST – GIA1 software
mismatch. Communication
Halted.
The system has detected an
incorrect software version loaded
in GIA1.
Load the correct software. See
Section 3.9 for the Software Loading
procedure.
MANIFEST – GIA2 software
mismatch. Communication
Halted.
The system has detected an
incorrect software version loaded
in GIA2.
GIA1 CONFIG – GIA1 audio
config error. Config service req’d.
The GIA’s audio configuration files
are incorrect or missing.
Reload audio configuration files.
GIA2 CONFIG – GIA2 audio
config error. Config service req’d.
GIA1 CONFIG – GIA1
configuration error. Config service
req’d.
The system has detected a GIA
configuration mismatch. If GIAs
are not properly configured after
being swapped/replaced, this
message appears.
Load the configuration files for that
GIA. See Section 3.9 for GIA 63
Configuration Loading
procedure.
If problem persists, replace
master configuration module,
check config module harness for
faults and replace if necessary.
NOTE
New Terrain/Obstacle cards,
Jeppesen Aviation Database and
other optional features (i.e. TAWS
unlock card) will need to be
replaced if the master configuration
module is changed. The G1000
System ID number will change to a
new number when installing a new
master config module. The old
Terrain and other cards will no
longer work as they will remain
locked to the old System ID
number.
GIA2 CONFIG – GIA2
configuration error. Config service
req’d.
HW MISMATCH – GIA hardware
mismatch, GIA1 communication
halted.
The G1000 has detected a non-
WAAS GIA 63.
Replace GIA with a WAAS unit.
HW MISMATCH – GIA hardware
mismatch, GIA2 communication
halted.
GIA1 SERVICE – GIA1 needs
service. Return unit for repair.
The G1000 has detected a failure
in the specified GIA.
Replace suspect GIA.
GIA2 SERVICE – GIA2 needs