Page 5-62 G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air
Revision 4 190-00716-01
5.11.5 GIA Cooling Alerts
Failure Message Cause Solution
GIA1 COOLING – GIA1
temperature too low.
GIA1 operating temperature is too
low.
Allow unit to warm up.
GIA2 COOLING – GIA2
temperature too low.
GIA2 operating temperature is too
low.
Allow unit to warm up.
GIA1 COOLING – GIA1 over
temperature.
GIA1 has exceeded its operating
temperature range.
Check fan, wiring and air tubing for
proper operation (if applicable).
Replace cooling fan if unable to
determine if operating correctly.
Replace GIA1.
If problem persists contact Garmin
Aviation Product Support for
assistance.
GIA2 COOLING – GIA2 over
temperature.
GIA2 has exceeded its operating
temperature range.
Check fan, wiring and air tubing for
proper operation (if applicable).
Replace cooling fan if unable to
determine if operating correctly.
Replace GIA2.
If problem persists contact Garmin
Aviation Product Support for
assistance.