Instruction Manual

G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air Page 7-15
190-00716-01 Revision 4
Table 7-5, Air Data System Test
Test
Point
Altitude (FT) Airspeed (KIAS)
Nominal
Altitude
AIR DATA 1 AIR DATA 2 AIR DATA 1 AIR DATA 2
ALT
AS
Tolerance Tolerance Tolerance Tolerance
Actual Actual Actual Actual
0
0
0
+/-20 +/-20 +/-2 +/-2
0
99
0
+/-20 +/-20 +/-2 +/-2
0
132
0
+/-20 +/-20 +/-2 +/-2
0
198
0
+/-20 +/-20 +/-2 +/-2
1000
50
1000
+/-20 +/-20 +/-2 +/-2
2000
50
2000
+/-25 +/-25 +/-2 +/-2
4000
80
4000
+/-25 +/-25 +/-2 +/-2
8000
80
8000
+/-30 +/-30 +/-2 +/-2
8000
260
8000
+/-30 +/-30 +/-2 +/-2
10000
120
10000
+/-30 +/-30 +/-2 +/-2
11000
120
11000
+/-35 +/-35 +/-2 +/-2
13000
150
13000
+/-40 +/-40 +/-2 +/-2
14000
150
14000
+/-40 +/-40 +/-2 +/-2
16000
180
16000
+/-45 +/-45 +/-2 +/-2
18000
210
18000
+/-45 +/-45 +/-2 +/-2
19000
138
18983
+/-47 +/-47 +/-2 +/-2
19000
162
18971
+/-47 +/-47 +/-2 +/-2
19000
185
18958
+/-47 +/-47 +/-2 +/-2
19000
209
18947
+/-47 +/-47 +/-2 +/-2
19000
233
18947
+/-47 +/-47 +/-2 +/-2
19000
242
18947
+/-47 +/-47 +/-2 +/-2