System Maintenance Manual
Page 5-8 G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air
Revision F 190-00682-01
PFD 2 ARINC 429
Channel LRU Indicator Status
IN 1 GRS 77 #2
PFD2/GRS 77 #2 data path is functioning correctly.
PFD2/GRS 77 #2 data path is not functioning correctly.
• Verify GRS77 #2 status is “OK” using the System Status
page on the MFD. If it is not, correct condition before
proceeding, reference GRS troubleshooting sections.
• Load PFD2 configuration file.
• Swap PFD2 and PFD1 to confirm if the problem is in the
original PFD2.
o Replace original PFD2 if box turns to a green
checkmark (√) after swapping displays.
• Swap GRS1 and GRS2 (no reconfiguration required) to
confirm if the problem is in the original GRS1.
o Replace original GRS1 if box turns green after
swapping units.
• Check the PFD2/GRS 77 #2 interconnect wiring for faults.
PFD2/GRS 77 #2 data path functionality is unknown. Reload
PFD2 configuration file.
IN 2 GDC 74 #2
PFD2/GDC 74 #2 data path is functioning correctly.
PFD2/GDC 74 #2 data path is not functioning correctly.
• Verify GDC 74 #2 status is “OK” using the System Status
page on the MFD. If it is not, correct condition before
proceeding, reference GDC troubleshooting sections.
• Load PFD2 and GDC 74 #2 configuration files.
• Swap PFD2 and PFD1 to confirm if the problem is in the
original PFD2.
o Replace original PFD2 if box turns to a green
checkmark (√) after swapping displays.
• Check the PFD2/GDC 74 #2 interconnect wiring for faults.
Replace GDC 74 #2 if problem remains.
PFD2/GDC 74 #2 data path functionality is unknown. Reload
PFD2 configuration file.