System Maintenance Manual

Page 5-8 G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air
Revision F 190-00682-01
PFD 2 ARINC 429
Channel LRU Indicator Status
IN 1 GRS 77 #2
PFD2/GRS 77 #2 data path is functioning correctly.
PFD2/GRS 77 #2 data path is not functioning correctly.
Verify GRS77 #2 status is “OK” using the System Status
page on the MFD. If it is not, correct condition before
proceeding, reference GRS troubleshooting sections.
Load PFD2 configuration file.
Swap PFD2 and PFD1 to confirm if the problem is in the
original PFD2.
o Replace original PFD2 if box turns to a green
checkmark () after swapping displays.
Swap GRS1 and GRS2 (no reconfiguration required) to
confirm if the problem is in the original GRS1.
o Replace original GRS1 if box turns green after
swapping units.
Check the PFD2/GRS 77 #2 interconnect wiring for faults.
PFD2/GRS 77 #2 data path functionality is unknown. Reload
PFD2 configuration file.
IN 2 GDC 74 #2
PFD2/GDC 74 #2 data path is functioning correctly.
PFD2/GDC 74 #2 data path is not functioning correctly.
Verify GDC 74 #2 status is “OK” using the System Status
page on the MFD. If it is not, correct condition before
proceeding, reference GDC troubleshooting sections.
Load PFD2 and GDC 74 #2 configuration files.
Swap PFD2 and PFD1 to confirm if the problem is in the
original PFD2.
o Replace original PFD2 if box turns to a green
checkmark () after swapping displays.
Check the PFD2/GDC 74 #2 interconnect wiring for faults.
Replace GDC 74 #2 if problem remains.
PFD2/GDC 74 #2 data path functionality is unknown. Reload
PFD2 configuration file.