Pole mount fixture Entity PRO Installation instructions Art no:380280
EN 2
EN About this manual The purpose of this manual is to provide you with the necessary information to install the pole attachment for the Entity PRO models Charging stations. Dimensions EPPFS This document contains general descriptions which are verified to be accurate at the time of printing. However, because continuous improvement is a goal at GARO, we reserve the right to make product modifications at any time. 427 mm Product function description. GARO offers two pole mount fixtures.
EN 1. Install the Pole mount fixture 3 The mounting process and toques used are the same for both the single and double pole mount fixtures . Before you start the installation, make sure that the cables are prepared and positioned according to national regulations. 1 60 mm 4 Note: Make sure that the pole is attached firmly to the ground. 2 6 Nm Note: The short screws are for single CS installation and the longs screws are for double CS installation.
EN 5 7 8 6 B A Note: Only if an ethernet cable (RJ45) (A) and/or a control cable (B) is used.
EN 2. Prepare the CS bracket for installation on the pole mount fixture 3 1 Note: Only if you install two CS on the pole mount fixture. Do this on installation brackets of the charging stations. Use a cable grommet to seal the hole to the steelplate. Note: Only if an ethernet cable is used. 2 Note: Only if an control cable is used.
EN 3. Attach CS bracket(s) to the pole mount fixture You can attach one or two charging station(s) to both the single (EPPFS) and the double (EPPFD) pole mount fixture. The double version (EPPFD) is recomended for daisychaining (when several CS & poles are installed using the same power cable) 3.2 Attach two CS brackets to the double (EPPFD) pole mount fixture 1 3.
EN 4. Cable routing There are several ways (depending on the CS version) to route the power cables when you install two charging stations and plan for daisy-chaining. Make sure that cable grommets are used at the holes of the incoming and outgoing power cables. Note: For outlet versions only: Do not pinch the power cable wires. Do not route the wires on the same side of the connection terminal as the outlet.
EN 9
GARO E-Mobility AB Box 203 335 33 Gnosjö, Sweden Phone +46 370 332 00 info@garo.se www.garo.se GARO Finland Oy Itälahdenkatu 18 a, FI-00210 HELSNKI, Finland Telephone: +358 20 752 9030 E-mail: myynti@garo.fi www.garo.fi GARO Electric Ireland Ltd 19/307 Northwest Business Park, Blanchardstown, IE-DUBLIN 15, Irland Telephone: +35 31 882 00 30 E-mail: info@garo.ie www.garo.ie GARO AS Sankt Hallvardsvei 3, NO-3414 LIERSTRANDA, Norway Telephone: +47 32 89 64 50 E-mail: garo@garo.no www.garo.