ES42 Series Edge Switches Installation and User Guide (05/05) Magnum™ ES42 Series Edge Switch Installation and User Guide Part #: 84-00141 Rev. A (02/05) Trademarks GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch, Edge Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
ES42 Series Edge Switches Installation and User Guide (05/05) Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication.
ES42 Series Edge Switches Installation and User Guide (05/05) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support@garrettcom.com www . GarrettCom .
ES42 Series Edge Switches Installation and User Guide (05/05) TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications ...................................................................... 1 1.2 Summary of models and descriptions: ............................................... 10 2.0 INTRODUCTION ............................................................................... 12 2.
ES42 Series Edge Switches Installation and User Guide (05/05) 3.7 ES42H and P Series, 12VDC, 24VDC and -48VDC Installation ...... 47 3.8 Connecting Ethernet Media ............................................................... 48 3.8.1 Connecting Twisted Pair............................................................. 50 3.8.2 Connecting Fiber Optic ST-type, “twist-lock”........................... 51 3.8.3 Connecting Fiber Optic SC-type, "Snap-In" .............................. 52 3.8.
ES42 Series Edge Switches Installation and User Guide (05/05) 5.4 Shipping and Packaging Information................................................. 67 APPENDIX A: WARRANTY INFORMATION......................................... 69 Revisions Rev A 05/05: Minor updates on MDIX (Auto-cross) Rev A 02/05: Initial release of this user manual for ES42 Edge Switches GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice. www . GarrettCom .
ES42 Series Edge Switches 1.0 SPECIFICATIONS 1.1 Technical Specifications Installation and User Guide (05/05) Ports Performance When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.
ES42 Series Edge Switches Installation and User Guide (05/05) Address buffer age-out time: 300 sec.
ES42 Series Edge Switches Installation and User Guide (05/05) Operating Environment ES42: 32ºF to 104ºF (0ºC to 40ºC) ES42H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL). -40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests. ES42P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL). -58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests.
ES42 Series Edge Switches Packaging: Installation and User Guide (05/05) Enclosure: Rugged sheet metal (Steel). Dimensions of the Switch unit: 3.7 in H x 3.0 in W x 1.7 in D (9.4 cm x 7.6 cm x 4.3 cm) Weight: all models: 9.5 oz. (285g); Power supply, –d, and i: 5.8 oz (165g) –Hd, and Hi: 5.8 oz (165g) –Pd, and -Pi: 7.9 oz (225g) Cooling Method: Convection on the office model.
ES42 Series Edge Switches Installation and User Guide (05/05) POWER SUPPLY These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to 500mA).When connected to a 48V centralized DC source, these products shall be provided with a Listed 5 A DC fuse in the supply circuit.
ES42 Series Edge Switches Installation and User Guide (05/05) International (-i) models. Input: 240vac at 50Hz with IEC 320 connector for the user supplied AC power cord. Output:12vdc, 1Amps Factory Floor Models (H) Ratings (-25 to 60°C) North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC 3power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Output:12vdc, 1.25Amps International (-Hi) models. Factory floor temperature rated.
ES42 Series Edge Switches Installation and User Guide (05/05) Direct DC POWER SUPPLY : built-in terminal block for +, -, ground along with 12VDC jack 12V DC internal (range 8.0 to 15V DC), 24V DC internal (range 10 to 36V DC), -48V DC internal (range 30 to 60V DC),+ , -, ground. Note: DUAL-SRC-24KIT- For ES42H or P -24VDC unit only (sold separately). See 3.6. Power Consumption: See Section 3.6. Note 1: the 12V DC jack can be used for dual source DC input using an AC adapter and the DC terminal block.
ES42 Series Edge Switches Installation and User Guide (05/05) Port Connectors: RJ-45 Ports: support 100BASE-TX and 10BASE-T with auto-cross (MDIX). They are shielded 8-pin female connectors for shielded (STP) and unshielded (UTP) Cat 3, 4, 5 cable. One Fiber optic port: On the ES42 Series it is 100Base-FX with a “fiber flavor” choice of multimode SC, ST, LC or MTRJ or single mode SSC, SSCL, SST or SLC connectors.
ES42 Series Edge Switches Installation and User Guide (05/05) Mounting options Metal mounting clips for panel mounting: included DIN-Rail mounting option: Model # DIN-RAIL MC2 (see Section 3.4) Rack-mount option: MC14-TRAY, see http://www.garrettcom.com/mc_tray.htm Depth: 6.0”, width: 17” Height: 2.25” (15cm D x 43cm W x 5.
ES42 Series Edge Switches 1.2 Installation and User Guide (05/05) Summary of models and descriptions: Note: The ES42 model # consists of the base unit type and the power input. Insert S for sgl-mode , the fiber flavor (2ff) and the power input. H- hardened, P-premium, R- Din –Rail MC2, ddomestic, i – international power type. The “2ff” field is for selection of the desired “fiber flavor” as listed below.
ES42 Series Edge Switches Installation and User Guide (05/05) ES42PR-2ff-24VDC = Same as ES42P-24VDC model, but includes DIN-RAIL-MC2 mounting opt. ES42P-2ff-48VDC = Same as ES42P-24VDC model, except -48VDC input replaces 24VDC. Note: For dual source 24V power input to DC jack, order Model# DUAL-SRC-24Kit “SC” = 100Base-FX-SC: multi-mode fiber optic with SC type connector, 2km. “SSC”= 100Base-FX-SSC: single-mode fiber optic with SC type connector, 20km.
ES42 Series Edge Switches 2.0 INTRODUCTION Installation and User Guide (05/05) This section describes ES42 Series models, including appearance, features and typical applications. 2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage which you believe occurred during shipment or delivery.
ES42 Series Edge Switches Installation and User Guide (05/05) Remove the Magnum ES42 Series Edge Switch from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or damaged contact your supplier. If you need to return the unit use the original shipping container. Refer to Section 5 Troubleshooting, for specific return procedures. 2.
ES42 Series Edge Switches Installation and User Guide (05/05) ports and two 100 Mb Fiber port or five copper ports with one 100Mb Fiber port built in, covers the full range of application environments, with regular (office), Hardened (factory floor), and Premium-rated (outdoor) versions. Extra features for heavy-duty and extended temperature operation ranges are included selectively in the Hardened factory-floor and Premium-rated outdoor models.
ES42 Series Edge Switches Installation and User Guide (05/05) pass the reconfiguration signal down the line to other ring switches in the redundant structure for faster recovery. Magnum Edge switches, combined with other Magnum managed switches, running STP/RSTP or S-Ring, can often provide high availability Redundant LANs at economical cost. LK / AC T 5 3 4 5 6 PORT 6 10 / 10 0 PW R 10 OR F 100 OR A 1 2 are for office and indoor wiring closet environments.
ES42 Series Edge Switches Installation and User Guide (05/05) A robust metal case with convection cooling is featured. Metal mounting clips are 5 5 4 6 10 / 10 0 PW R 6 1 2 PORT 4 3 E 40°C. Storage temperature rating is - E 2 FH2 1 RX 10/100 FH2 nu m 42 Edg e S S w it ch RX Ma g TX operating temperature is 0° to TX 10/ 100 A LA RM 10/100 cooling is featured.
ES42 Series Edge Switches Installation and User Guide (05/05) mounting and optional DIN-Rail mounting. The regular model ES42 also has a rackmount option via an MC-TRAY. 3 5 5 4 6 10 / 10 0 PW R PORT 6 regular ES42 model does not have options for Alarm and 2 1 10 OR F 100 OR A MDIX ports and the full range of fiber port options. The LK / AC T LK / AC T The regular model, ES42, includes Link-Loss-Learn, PORT 3 4 DC power. special thermal techniques and a metal case for Fig. 2.2.
ES42 Series Edge Switches Installation and User Guide (05/05) heavy duty industrial jobs. In addition to a Hardened AC power option and jack, terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included. The ambient temperature rating of –25 to 60C is for industrial use. No internal air flow is required for cooling, so it resists dust, dirt, moisture, smoke and insects.
ES42 Series Edge Switches Installation and User Guide (05/05) AC or internal DC power are available. Ambient operating temperature is –25°C to + 60°C depending on the power source used. Storage temperature rating is –25°C to + 85°C. LK / AC T 5 LK / AC T 6 5 4 5 6 3 4 2 RM 12 VDC 1 AMP www . GarrettCom .
ES42 Series Edge Switches Installation and User Guide (05/05) The ES42P series (as shown in Fig. 2.2f & g) are premium rated units suitable for temperature un-controlled outdoor applications. Specially designed with premium-grade extended temperature components, the ES42P units use similar thermal techniques to the ES42H hardened units for cooling. Mounting options include panelmounting, DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC power are available.
ES42 Series Edge Switches Installation and User Guide (05/05) auto-cross (MDIX) operation under auto-negotiation mode. The ES42 series provides switching among four 10/100 auto-negotiating copper ports and two 100Mb fiber ports which may be SC, ST, MTRJ or LC multi-mode or single-mode. The ES42’s breadth of fiber options and well as temperature options provide many networking options and solutions in a very small footprint.
ES42 Series Edge Switches Installation and User Guide (05/05) There is a power (PWR) LED to indicate that the unit is turned ON. The fiber ports on the ES42 Edge switches are multi-mode or single-mode with an SC, ST or small form factor connector (MTRJ multi mode or LC single-mode). The external DC power plug connector and/or “jack” and the internal DC input terminal is provided on the rear of the unit. 2.3 Frame Buffering and Latency The Magnum ES42 Series Edge Switches are store-and-forward switches.
ES42 Series Edge Switches Installation and User Guide (05/05) network. The "cut-through" technique permits collision fragment frames, which are a result of late collisions, to be forwarded--which add to the network traffic. There is no way to filter frames with a bad CRC (the entire frame must be present in order for CRC to be calculated).
ES42 Series Edge Switches Installation and User Guide (05/05) traffic loads, even when the traffic activity is unbalanced across the ports. Since the traffic on an operating network is constantly varying in packet density per port and in aggregate density, the Magnum ES42 Series Edge Switches are constantly adapting internally to provide maximum network performance with the least dropped packets.
ES42 Series Edge Switches Installation and User Guide (05/05) The latency (the time the frame spends in the Switch before it is sent along or forwarded to its destination) of the ES42 Series Edge Switches varies with the port-speed types. The length of the frame is a variable as it is with all store-and-forward switches. For 10 Mb-to-10 Mb, 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the latency is 15 microseconds plus the packet time of 10 Mb.
ES42 Series Edge Switches Installation and User Guide (05/05) Choice of one or two100Mb Fiber option, more efficient Designed as a multi-purpose media Edge Switch, the 100Mb fiber port allows the user to convert the media from copper to fiber and the other RJ-45 port can be used as diagnostic port or for more connectivity.
ES42 Series Edge Switches Installation and User Guide (05/05) Qualified to use for temperature un-controlled “outdoor” application The Magnum ES42P Premium rated versions of Edge Switches have an ambient temperature rating between –40ºC to +75ºC for DC models and qualify for temperature un-controlled “outdoor” application.
ES42 Series Edge Switches Installation and User Guide (05/05) Link-Loss-Learn feature for faster recovery in redundant managed network The LLL feature qualifies the Edge switches to actively work along with redundant network structure as a client switch and allow a faster recovery during ring break. 2.
ES42 Series Edge Switches Installation and User Guide (05/05) requirements via providing edge support and reliability to the managed redundant network. The Dual-Speed and Dual-media functions support a mixed environment of 10 Mbps and 100Mbps users with copper and fiber media. The switched full duplex fiber port also provides high bandwidth and longer distance support. The up-link feature of 100Mb fiber on Ports 1 and 2 enable easy expansion for the on-going demand of Ethernet networks.
ES42 Series Edge Switches Installation and User Guide (05/05) 3 LK LK TX 5 7 LK PORT 7 1 LK/ ACT 5 3 10/ 100 PW R RX 1 5 TX LK 6 10/ 100 ACT F/H ACT F/H RX PORT ACT F/H ACT F/H RX ACT F/H ACT F/H LK 2 LK LK 4 LK 6 8 3 TX 2 RX 4 2 3 1 ACT F/H ACT F/H ALARM 4 TX LK CONSOLE PORT 5 1 PWR PORT 6 5 6 10 O RF 100 OR A LK/ ACT LK/ ACT PW R 10/ 100 2 3 4 5 PORT 6 1 10 OR F 100 OR A LK/ ACT Example1.
ES42 Series Edge Switches Installation and User Guide (05/05) This need can be easily met using the economical Magnum ES42 Edge Switch. Additional functionality includes the ability to transfer data across large distances with multi- or single–mode fiber while securing the LAN from EMI and wire tapping. The ES42’s six ports in a small, reliable enclosure provide an effective solution to for transferring real-time transactions from the store to the storage device in the control room.
ES42 Series Edge Switches Installation and User Guide (05/05) Example 2: ES42H and CSN14H In this industrial networking application, the new PLC units are deployed on a network expansion, and each PLC required one (or two for redundancy) Ethernet ports to carry status and control data to the control center. The ES42H and CS14H provide a good solution with their multiple options and hardened features. The two Fiber ports on the Edge switches are ideal for secure data communications over long distances.
ES42 Series Edge Switches Installation and User Guide (05/05) 1 3 5 7 9 11 13 15 17 19 21 23 1 ACT F/H ACT F/H 3 5 7 6 8 ACT F/H ACT F/H 2 4 6 8 10 12 14 16 18 20 22 ACT F/H ACT F/H ACT F/H ACT F/H 2 24 4 G a r r e ttC o m 16 V M ag num 6 K PWR CONS OLE PORT G a r r e ttC o m G a r r e t tC o m V M agn um 6 K 16 V M agn um 6K 16 PWR PWR A PORT 6 5 F OR PWR 100 1 10 / 100 2 3 4 5 PORT CONSOL E PORT 6 10 OR LK/ ACT LK/ ACT G a r r e tt C o m M a
ES42 Series Edge Switches Installation and User Guide (05/05) Example 3: ES42P: In this example, the Magnum ES42P premium Edge Switches are deployed to serve as a secure corporate or transportation surveillance system. CCTV cameras may be spread out over many miles in temperature un-controlled locations and with pan, tilt and zoom (PTZ) controlled through an Ethernet copper port .
ES42 Series Edge Switches 1 3 5 7 9 11 13 15 Installation and User Guide (05/05) 17 19 21 18 20 22 23 AC T F/H AC T F/H 8 10 12 14 16 24 3 5 7 2 4 6 8 ACT F/H ACT F/H ACT F/H ACT F/H 4 5 2 6 10 1 0 0/ PWR LK/ ACT 6 6 1 4 5 10 O R 100 F OR A LK/ ACT 2 3 1 ACT F/H ACT F/H i Mac PORT 3 4 PORT 2 CCTV Camera i Mac LK/ ACT 6 F A LK/ ACT OR OR PWR 10 10 0 1 10 1 0 0/ 2 3 4 PORT 5 3 4 5 PORT 6 FH2 h TX 12 VDC 1 AMP 0 R X 1 0 /10FH2 m E
ES42 Series Edge Switches 3.0 Installation and User Guide (05/05) INSTALLATION This section describes the installation of the Magnum ES42 Series Edge Switches, including location, mountings, power supply options and media connection. 3.1 Locating the Edge Switch Unit All the ES42 Series Switches operate in transparent half-and full-duplex mode.
ES42 Series Edge Switches Installation and User Guide (05/05) The compact and lightweight design of the Magnum ES42 Series allows it to be easily installed in almost any location. A Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or shelf. Alternatively, metal mounting clips and screws are included for a rugged and secure mounting in any orientation.
ES42 Series Edge Switches Installation and User Guide (05/05) 3.2 MC14-TRAY for Rack Mounting of ES42 Series Switches For 19” rack-mounting of Magnum ES42 series Edge Switches, a rack-mount tray is available, the MC14-TRAY. The Edge Switches are mounted with the DC power jack in the back, with the fiber and the RJ-45 connectors in the front. Any mix of the Edge Switches and/or www . GarrettCom .
ES42 Series Edge Switches Installation and User Guide (05/05) Media Edges may be placed on a tray, up to a maximum of 8 units. (The mounting spaces of the MC14-TRAY are specific to the Magnum products and will not permit other models to be properly mounted). In a typical installation, the MC14-TRAY, 19” rack-mount tray will hold a few (three to eight) ES42 Series Edge Switches, with their power supplies plugged into power strips (not included) in the rear area of the tray.
ES42 Series Edge Switches Installation and User Guide (05/05) has two groups of eight units per power supply. The power supplies have auto-ranging AC input for use worldwide. The side-view < here is an example of an installation of the model MC14TR+PS9, 19” rack-mount tray, holding a few ES42, and 14E Media Edges, each with their power input plugged into the built-in common AC power supply in the rear area of the tray. (AC PS units that come with the office models of the Edge Switch’s are not used).
ES42 Series Edge Switches Installation and User Guide (05/05) 3.4 DIN-Rail mounting option The Magnum ES42H and ES42P Edge Switches, designed for use in “Factory Floor” Industrial Ethernet environments, are available for DIN-Rail mounting in an enclosure having DIN Rails A Magnum ES42H is shown alongside the DIN-RailMC2 bracket here -> The metal DIN-Rail mounting hardware is optional and needs to be ordered as a separate item, e.g. Model #DINRAIL-MC2.
ES42 Series Edge Switches Installation and User Guide (05/05) 3.5 Power Requirements, Power Supply Types for ES42 Series Switches Magnum ES42 Series Switches are power-efficient and can work with an external AC power supply. Magnum ES42 Series require a nominal 12VDC input version. The extended temperature (H and P) versions are used for heavy duty industrial applications. The 12V DC power input jack has a plug of 2.5mm, center +ve , with 6 ft. cord.
ES42 Series Edge Switches Installation and User Guide (05/05) withstand higher temperature environments, and provide the DC power choices to the user to deploy in uncontrolled temperature environments. The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in terminal block for +, -, ground. The 9V DC jack is also present. Detail information about the 12 VDC, the 24V DC and the –48V DC is provided in the Technical Specifications Section 1.1.
ES42 Series Edge Switches Installation and User Guide (05/05) 3.6 Powering the ES42H and ES42P (DC internal) with 12V, 24V or –48VDC power input Each Magnum ES42H/ES42P-Series is equipped with an internal DC power supply, and has built-in screw terminals for secure attachment of the power input leads. Three DC power models support a range of power input types. The three DC power input terminal block choices are for use with 12VDC, 24VDC or -48VDC power.
ES42 Series Edge Switches Installation and User Guide (05/05) Note: The ES42H or P models with 24VDC support the Dual Source 24V input option. An external Dual-SRC-24KIT (SHOWN AT RIGHT…and sold separately, or a customersupplied equivalent) can be used to input 24VDC power to the ES4H or P unit via the jack. This is for 24VDC models only. www . GarrettCom .
ES42 Series Edge Switches Installation and User Guide (05/05) 3.6 continued, DC Power Terminals: “+”, “-”, gnd GND: Terminal for “earth” or ground wire connection to the ES42H chassis Input Voltage: 12VDC 24VDC -48VDC Alarm Contact Terminal 12VDC (8-15VDC) (12V) (8-15VDC) 24VDC (10-36VDC) -48VDC (30-60VDC) (12V or 24V) (10-30VDC) (12V) (8-15VDC) Input current: 0.8 amp.(12V DC) 0.4 amp max.(24V DC) 0.2 amp max.(-48V DC) Power Consumption: 7 watts typical, 9 watts max. www . GarrettCom .
ES42 Series Edge Switches Installation and User Guide (05/05) 3.7 ES42H and P Series, DC-powered, 12VDC, 24VDC and -48VDC Installation This section describes the proper connection of the -48VDC leads (or 24VDC, 12VDC leads) to the DC power terminal block on the Magnum ES42H Edge Switch (as shown in the Figure). The DC terminal block on the Magnum ES42H is located on the left side of the unit and is equipped with three (3) screw-down lead posts.
ES42 Series Edge Switches Installation and User Guide (05/05) the DC leads to the ES42H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) optional; it connects to the ES42H chassis. Ensure that each lead is securely tightened from the top, as shown on above picture with arrow. NOTE: Always use a voltmeter to measure the voltage of the incoming power supply and figure out the +ve potential lead or -ve potential lead.
ES42 Series Edge Switches Installation and User Guide (05/05) ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328 ft). For fiber port 10BASEFL or 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring.
ES42 Series Edge Switches 3.8.1 Installation and User Guide (05/05) Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded) The following procedure describes how to connect a 10BASE-T or 100BASE-TX twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted pair cables. 1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port.
ES42 Series Edge Switches Installation and User Guide (05/05) 3.8.2 Connecting Fiber Optic ST-type, “twist-lock” The following procedure applies to installations using ST-type fiber connectors. This procedure applies to ports using multi-mode ST fiber connectors. 1. Before connecting the fiber optic cable, remove the protective dust caps from the tips of the fiber connectors. Save these dust caps for future use. 2.
ES42 Series Edge Switches 3.8.3 Installation and User Guide (05/05) Connecting Fiber Optic SC-type, "Snap-In" The following procedure applies to installations using SC-type fiber connectors, i.e., using multi-mode SC and SC single-mode. While connecting fiber media to SC connectors, simply snap on the two square male connectors into the SC female jacks of the Fiber connector until it clicks and secures. 3.8.
ES42 Series Edge Switches Installation and User Guide (05/05) 3.8.5 Power Budget Calculations for ES42 Series, Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget.
ES42 Series Edge Switches Fiber Port Module Speed, Std. Mode Std. km Wavel Cable X’mitr R’cvr Worst Worst* typical typical* fdx ength Size Output Sens. OPB, distance OPB, distance (hdx) nm dB Km, fdx µm PT , dB PR ,dB dB Km, fdx ES42- 100Mb Multi2 mode (0.4) MST, MSC FX 100Mb Single- 20 ES42-SSC FX mode (0.4) ES42MTRJ Long Reach 100Mb Multimode FX Installation and User Guide (05/05) 2 (0.4) 100Mb Single- 40 mode (0.4) FX 1310 62.5/125 -20 50/125 -23.5 -31 -31 9.0 5.5 2.5 2.
ES42 Series Edge Switches Installation and User Guide (05/05) * Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following factors are both applied: • The 100Mb fiber segment must operate in full-duplex (FDX) mode, and • The worst-case OPB of the fiber link must be greater than the fiber cable’s passive Attenuation.
ES42 Series Edge Switches 4.0 OPERATION Installation and User Guide (05/05) 4.1 Dual-Speed Functionality, and Switching The Magnum ES42 Series Edge Switches provide SIX switched ports with combination of fiber and copper or copper only. The architecture supports a dual speed switching environment, with standard auto-negotiation capability. The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and speed, and auto-cross for plug polarity. (See Section 4.2).
ES42 Series Edge Switches Installation and User Guide (05/05) devices. There is no software configuring to be done at installation or for maintenance, even for the LLL ports. The internal functions of both are described below. Switching, Filtering and Forwarding Each time a packet arrives on one of the switched ports, the decision is taken to either filter or to forward the packet.
ES42 Series Edge Switches Installation and User Guide (05/05) nodes are added or removed or moved from one segment to another, the ES42- Series switch automatically keeps up with node locations. An address-aging algorithm causes least-used addresses to fall out in favor of new frequently-used addresses. To reset the address buffer, cycle power down-and-up. 4.
ES42 Series Edge Switches Installation and User Guide (05/05) at the other end of the cable should similarly advertise / respond. Both sides will agree to the speed and mode to be used per the IEEE 802.3u standard. Depending upon the devices connected, this will result in agreement to operate at either 10 Mbps or 100Mbps speed, and full- or half-duplex mode. www . GarrettCom .
ES42 Series Edge Switches Installation and User Guide (05/05) 4.3 Dual LEDs, Front-panel and side-panel (Magnum ES42 Series) LED Description PWR Illuminates GREEN to indicate power applied. LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn off in the event connectivity is lost between the ends of the twisted pair segment or a loss of power occurs in the unit or remote device. The Link ports are also represented by LA1, LA2, LA3…LA6.
ES42 Series Edge Switches Installation and User Guide (05/05) 4.4 Hardware operated Alarm Contact for monitoring internal power supply The two screws Alarm Contacts feature, standard on Magnum ES42H and P, provides Normally Closed (NC) contacts to which the user can attach one sets of status monitoring wires at the green terminal block. When this option is present, the terminal block for Alarm Contacts is part of the Power Input panel in the Magnum ES42s case.
ES42 Series Edge Switches Installation and User Guide (05/05) 1. Two-position terminal block (1,2) provided next to the DC power input, as shown above. 2. The Alarm Relay contact connected to the two terminals (1,2) is hardware operated. 3. By default it is NC (normally closed). It will open if there is any loss of power to the electronics inside of the unit. 5.
ES42 Series Edge Switches Installation and User Guide (05/05) procedures described in this section or if the Magnum ES42 Series 10/100 Mb/s Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support. 5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual.
ES42 Series Edge Switches Installation and User Guide (05/05) 3. If the fiber port does not link up while connecting to other device, do a quick Loop test to test the fiber transceiver is functional or not. Use a short patch cable of fiber and connect one end of cable to transmit and other end of receive to the fiber port transceiver. If the Link Led turns solid green, then the fiber port is functional and working. 4. Make sure that an AC power cord is properly attached to each Magnum ES42-Series unit.
ES42 Series Edge Switches Installation and User Guide (05/05) corrected, the Magnum ES42 Series Switch and its associated cables are functioning properly. 6. If the problem continues after completing Step 5 above, contact your supplier of the Magnum ES42 Series 10/100 Mb/s Switch unit or if unknown, contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for assistance. 5.2 When Calling for Assistance Please be prepared to provide the following information. 1.
ES42 Series Edge Switches 2. Installation and User Guide (05/05) An accurate list of GarrettCom product model(s)involved, with serial number(s). Include the date(s) that you purchased the products from your supplier. 3. It is useful to include other network equipment models and related hardware, including Convenient computers, workstations, terminals and printers; plus, the various network media types being used, along with diagram of network setup. 4.
ES42 Series Edge Switches Installation and User Guide (05/05) https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form. Please have the following information readily available: Name and phone number of your contact person. Name of your company / institution Your shipping address Product name Serial Number (or Invoice Number) Packing List Number (or Sales Order Number) Date of installation Failure symptoms, including a full description of the problem.
ES42 Series Edge Switches Installation and User Guide (05/05) with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as: No Problem Found. GarrettCom reserves the right to charge for the testing of non-defective units under warranty. Testing and repair of product that is not under warranty will result in a customer (user) charge. 5.
ES42 Series Edge Switches Installation and User Guide (05/05) or bag for shipping protection. (You may retain all connectors and this Installation Guide.) CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the unit. 2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container. 3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to: GarrettCom, Inc.
ES42 Series Edge Switches Installation and User Guide (05/05) APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom.