Corporate Headquarters GarrettCom, Inc. Magnum 6K25 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Managed Fiber Switch email support@garrettcom.com Hardware Installation and User Guide www . GarrettCom . com www . GarrettCom .
Magnum 6K25 Managed Fiber Switch Installation and User Guide 04/06) Magnum™ 6K25 Managed Fiber Switch Hardware Installation and User Guide Part #: 84-00123 (Rev. D) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
Magnum 6K25 Managed Fiber Switch Installation and User Guide 04/06) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed GarrettCom, Inc. below: 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.
Magnum 6K25 Managed Fiber Switch Installation and User Guide 04/06) TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ................................................................................ 1 1.1 Technical Specifications....................................................................... 1 1.2 Ordering Information ........................................................................... 4 2.0 INTRODUCTION.................................................................................. 7 2.
Magnum 6K25 Managed Fiber Switch Installation and User Guide 04/06) 5.1 Inspecting the Package and Product................................................... 41 5.2 6KPM Module Description ................................................................ 41 5.2.1 6KP6-RJMST, Combo Module ................................................. 42 5.2.1a 6KP6-RJ10ST, Combo Module................................................. 42 5.2.1b 6KP4-F10ST, Module ...........................................................
Magnum 6K25 Managed Fiber Switch Installation and User Guide 04/06) 01/05: minor updates and tweak on LC port modules 06/04: New port modules has been added and updates on Alarm contact 02/04: Minor update, and added Section 3.4.1, Alarm Contact option. 11/03 : Minor updates, Network standards & Console port pin Assign. 03/03 : Minor updates on power budget calculations , Gigabit fiber Rev D 10/02 : Updated the Rack Mount options and brackets, Section 3.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc. offers the premium-quality Magnum™ line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary consideration.
Magnum 6K25 Managed Fiber Switch 1.0 1.1 Installation and User Guide (04/06) SPECIFICATIONS Technical Specifications Performance Filtering / Forwarding Rate: Ethernet:14,880 pps Fast Ethernet: 148,800 pps Gigabit Ethernet: 1, 488,000 pps Switching Processing Type: Store and Forward with IEEE 802.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) Fiber Port, ST-type (twist-lock): Fiber optic m.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) are interrupted), see Appendices B and C. Per-port MDI or MDIX on RJ-45 The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45 ports., and eliminate the use of cross-over cable between the devices. Also portspecific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed using software commands. Alarm Contact (Optional) Alarm Contact option is offered as a configuration option.
Magnum 6K25 Managed Fiber Switch 1.2 Installation and User Guide (04/06) Ordering Information Magnum Managed Fiber Switch MODEL DESCRIPTION Magnum 6K25 Magnum 6K25 Managed Fiber Switch, base unit. May be configured with a selection of 10/100/1000 6K25 fiber and copper port connector types, 25 total ports max. Wire speed filtering and forwarding across all ports, 802.3x flow control, 802.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) For Gigabit module configuration options GBPM-COTX One slot Gigabit 6K module for 6K25 Switches, uses one 6K25 slot and provides one GBIC open transceiver port for a user-selectable GBIC transceiver module GBIC-SXSC GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-SX port with mm SC fiber connector GBIC-LXSC10 GBIC transceiver module for use in GBPM-xOTX, one 1000BASELX/LH port with 1310nm sgl.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) source and four 100 Mb 15km Sm FX LC connectors New P6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 2km mm FX ST connectors New P6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 2km mm FX SC connectors New P6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power source and two 100 Mb 20km sm FX SC connectors New P6KP6-RJSSCL “4+2”
Magnum 6K25 Managed Fiber Switch 2.0 2.1 Installation and User Guide (04/06) Introduction Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Magnum 6K25 Managed Fiber Switch 2.2 Installation and User Guide (04/06) Product Description - Magnum 6K25 Managed Fiber Switch The Magnum Managed Fiber Switch boosts the performance of large Ethernet LANs, typically serving as a “backbone” switch. It has the flexibility to handle a mix of both fiber and twisted-pair switched ports along with Gigabit backbone port options. Industry-standard IEEE 802.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) LEDs in the front and the power input and management console connector in the rear) or “Reverse” (with the ports and LEDs and the power-input and the management console connector all in the rear and a duplicate set of LEDs in the front). Rack widths accommodated include standard 19” RETMA, ETSI, and 23” Telco. Input power may be AC, or –48VDC for Telco environments, or 24VDC for Industrial applications.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) “Reverse” rack-mount models, there is a duplicate set of LEDs on the other (front) side for normal status viewing from that direction. Of course, with management, the port status data is also available in software. 2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiber 1 3 5 7 ACT ACT F/H ACT F/H ACT F/H F/H LK LK LK LK ACT ACT F/H F/H ACT ACT F/H LK 2 4 LK LK 6 8 LK Fig.2.2.
Magnum 6K25 Managed Fiber Switch 2.2.3 Installation and User Guide (04/06) Eight-Port Copper Module, 6K8-RJ45 The 6K25-Series’s 8-port 1 Copper port module, model 6K8-RJ45, provides eight 5 7 LK 10/100 10/100Mb switched RJ-45 ports. The 10/100Mb switched 3 F/ H 2 4 6 ACT 8 10/100 LK F/H ACT ports normally (as a default setting) are independently Nway auto-negotiating, and autocrossover(MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode, i.e.
Magnum 6K25 Managed Fiber Switch 2.2.4 Installation and User Guide (04/06) New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port The New PoE RJ-45 ports act similar to regular RJ-45 ports, except they have capability of providing power on each port to power up the PD devices, per the IEEE802.3af PoE 6KP8-45RJ standard. Only 4 x RJ8 Port@ 10/100Mb Copper ports 45 (10/100) ports maxm. support 2 POE(Power Inside) 1 3 5 LK/AC 1 option in one rack 10/10 mounted 6K-unit.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) Sec.1.2 for all the various P6K PoE modules option. The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when connected properly to a 803.af compliant PD device on that port. When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data traffic is not affected by PoE.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) The Magnum Combo 1 3 5 7 LK 10/100 six-port modules are also available with 4@ MTRJ 100Mb mm SFF ACT F/H ACT ACT F/H F/H 2 TX LK RX 6 fiber and 2@10Mb fiber mm ST TX LK RX ports, and with 4@ RJ45 10/100 copper and 2@10Mb fiber mm ST ports. The 4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of the module is as described for those port types above.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) The 6K25 Modules provide a GBIC opening for insertion of industry-standard GBICs to provide Gigabit (Gb) media flexibility. GBIC models are available for both multi-mode (550m) and single-mode (10, 25, 40, 70)km fiber options, and for Gigabit copper as well, with new models appearing often.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) of the available bandwidth to be used for valid information. While other switching technologies (such as "cut-through" or "express") impose minimal frame latency, they will also permit bad frames to propagate out to the Ethernet segments connected. The "cut-through" technique permits collision fragment frames (which are a result of late collisions) to be forwarded which add to the network traffic.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) www.GarrettCom.com/techsupport/index.htm#software and look for Magnum MNS-6K info.. Magnum MNS-6K Operator Training – This interactive training software allow the basic and advanced info about the Magnum MNS-6K management software and a useful tool for first time user. or email: support@GarrettCom.com for further information. 2.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) NEBS and ETSI tested and certified The 6K25 has been tested and certified for NEBS and ETSI. Request test reports. MNS-6K licensed Network Management Software included, S-Ring optional Release 2.
Magnum 6K25 Managed Fiber Switch 2.4 Installation and User Guide (04/06) Applications Magnum 6K25 Fiber Switches offer high performance and modularity. They provide the flexibility of 100Mbps fiber and copper ports as well as Gigabit ports, with industry-standard LAN management software.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) Full-duplex future proof fiber media can easily connect long distance subnets and provide a stable secure network to all applications. The SNMP management capability of the Magnum 6K25 Switch helps create a database of all the network subnets to easily manage the network.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) 1000Mb Data Mining Servers Magnum Magnum 6K25 QS5116PWR Magnum QS5116 Magnum 8 00E Workgroup Hub 100 Mb /s PWR COL 1 4 2 3 LI NK RX 5 8 6 Managed Fiber Fiber Switch Switch 7 LI NK RX GA RRETT 1 3 5 7 LK 10/100 10/100 F/ H 10/100 2 4 ACT8 LK 6 F/H 1 3 5 F/H ACT F/H 2 TX LK RX GARRE TT ACT ACT F/H TX 6 1 7 LK 10/100 ACT F/ H 10/100 LK RX 3 2 5 4 7 LK ACT8 LK 6 F/H ACT Internet Magnum DS8016 Stackabl
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) Switches are typically rack mounted in a wiring closet see Section 3.3.2 below), but because they have rubber feet they can also be installed on a shelf or table top unit. The compact size allows it to be easily placed in an office or lab area, and it can also be either shelf of wall-mounted (see Section 3.3.1 below). Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 6K25 site.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) connectors. This procedure applies to ports using a 6K25 module, MST-type port. 1. Before connecting the fiber optic cable, remove the protective dust caps from the tips of the connectors on the PM. Save these dust caps for future use. 2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting.
Magnum 6K25 Managed Fiber Switch Media Installation and User Guide (04/06) IEEE Standard Connector 10BASE-T RJ-45 100BASE-TX RJ-45 Twisted Pair (CAT 3, 4, 5) Twisted Pair (CAT 5) NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10 Mb and 100Mb) be used whenever possible in order to provide flexibility in a mixed-speed network, since dual-speed ports are auto-sensing for either 10 and 100Mb/s. 1. 2. 3.
Magnum 6K25 Managed Fiber Switch 3.3 Installation and User Guide (04/06) Table-Top or Shelf Mounting The Magnum 6K25 Manageable Switches can be easily mounted on a table-top or any suitable horizontal surface, and has four rubber feet to provide stability without scratching finished surfaces. 3.3.1 Rack-mounting (for 19” RETMA racks), regular Magnum 6K25s Installati on of a Magnum 6K25 Fiber Switch in a 19” rack is a simple procedure. The units are 1U (1.70”) high.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) The bracket mounting holes in the sides of the Magnum 6K25 permits it to be mounted in various ways. The same holes fit all three types (19”, ETSI, 23”) of brackets. The mounting for the 23” is illustrated in Figure 3.3.1 below. The brackets may be attached flush with the front, or attached in the center for a set-back mounting which may reduce cabling torque.
Magnum 6K25 Managed Fiber Switch 3.4 Installation and User Guide (04/06) Powering the Magnum Managed Fiber Switch The Magnum 6K25 Switches incorporate an internal universal power supply and have a recessed male IEC connector for the AC power cord at the left-rear. A manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power cord is supplied with each unit shipped within the United States and Canada.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) 4. By default it is NC (normally closed) 5. The software operation need to be enable and set to get the Alarm traps. For detail information about the Software Alarm and software control of SNMP alarm traps, please reference the Magnum MNS-6K Software User Manual. (Chapter 19th). 3.5 6K25 Port Module (6KPM) Installation The Magnum 6K25 Switches are normally received from the factory with all required 6KPM modules installed.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) on the front-bottom and rear-top of the unit and four screws each on the sides. Remove these screws. Once these are removed, the top cover is easily lifted off the chassis base. When the chassis top cover has been removed, the interior of the unit is exposed. Figure 3.5.1a: Removing Chassis Cover Caution: Be careful not to disturb the power supply.
Magnum 6K25 Managed Fiber Switch 3.5.2 Installation and User Guide (04/06) Installing 6KPM Cards in the Magnum 6K25 Up to four front-mounted 6KPM cards may be installed in one Magnum 6K25 Managed Fiber Switch unit. Follow these steps to install a 6KPM. Step 1. Remove top chassis cover. See procedure in Section 3.5.1 above. Step 2. Placed Granddaughter board (as shown in fig. 3.5.2a and 3.5.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) Fig. 3.5.2c Daughter Board, top view of version for 4 copper 10/100 ports. Port# 1 Uplink Can be configured as uplink (x) crossed ports for cascading as shown in the Fig. Fig 3.5.2d Daughter Board shown upside down with two male latch connectors Step 4.
Magnum 6K25 Managed Fiber Switch Step 5. Installation and User Guide (04/06) Once the latching connectors are aligned properly and the mounting holes are aligned with stand offs then press slowly and firmly with two fingers (as shown below in Fig. 3.5.2f) on the top of the latching connectors until the connectors latched up securely. Figure 3.5.2f: Securely latching up 6KPM Cards into a Magnum 6K25 NOTE: All 6KPM slots need not be filled in order for the Magnum 6k25 unit to be operational.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) brackets and 6 #256 flat head screws. The brackets and screws have been installed inside of the top cover as shown in Fig. 3.5.2h. Fig. 3.5.2h Inside view of chassis cover (from the rear), showing the front panel screen plates installed inside the chassis cover using brackets and screws Step 8. Once all 6KPM cards have been installed (including faceplates for empty slots), the chassis cover should be replaced.
Magnum 6K25 Managed Fiber Switch Step 3. Installation and User Guide (04/06) Remove 6KPM Card Carefully and gently pull out the daughter board from the latching connectors, using both hands, gripping the board near the latch-up connectors as shown in Fig. 3.5.3b . If the now empty slot is to remain unused, be sure to install a 6KPM-BLNK face plate cover. Figure 3.5.
Magnum 6K25 Managed Fiber Switch 3.6.1 Installation and User Guide (04/06) RS-232 (DB-9) Console Com port (Serial port) pin assignments.
Magnum 6K25 Managed Fiber Switch 4.0 Installation and User Guide (04/06) OPERATION This chapter describes the functions and operation of the Magnum 6K25 Switch. 4.1 Switching Functionality A Magnum 6K25 provides switched connectivity at Ethernet wire-speed among all of its ports. The Magnum 6K25 supports10/100Mbs for copper media and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance.
Magnum 6K25 Managed Fiber Switch 4.2 Installation and User Guide (04/06) Status LEDs For all Magnum 6K25 models : PWR LK ACT F/H 100/10 4.3 : Power LED, ON when external power is applied to the unit. : Steady ON, Link status for 10 Mbps and 100Mbps operation. : ON with port activity for 10 Mbps and 100Mbps operation. : Full / Half duplex LED, ON when the port is running full duplex, OFF for half duplex.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) Switch’s RJ-45 ports handle this situation by configuring the ports as per desire through MNS software port settings and can check the port status of each port after the change. When Magnum 6K25 RJ-45 copper ports are set for auto-negotiation and are connected to another auto-negotiating device, there are 4 different speed and F/H modes possible depending on what the other device supports.
Magnum 6K25 Managed Fiber Switch 4.5 Installation and User Guide (04/06) Flow-control, IEEE 802.3x standard Magnum 6K25 Switches incorporate a flow-control mechanism for Full- Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full. This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) The following data has been collected from component manufacturer’s (Agilent’s and Lucent’) web sites and catalogs to provide guidance to network designers and installers. Fiber Port Module Speed, 6KP4F10ST 10Mb MultiMode FL Std. Mode Std. Wave Cable X’mitr R’cvr Worst Worst* typical typical* km Size Output Sens. OPB, distance OPB, distance fdx length µm dB Km, fdx PT , dB PR ,dB dB Km, fdx (hdx) nm 850 62.5/125 -15.0 100/140 -9.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) 5.0 Introduction - Magnum 6K25 Managed Fiber Switch Port Modules This chapter describes each Port Module (PM), including appearance, functionality, and status displays. 5.1 Inspecting the Package and Product This section applies only to PMs shipped as separate items, i.e., 6K25 PMs not factory installed in a Magnum 6K25 PM slot.
Magnum 6K25 Managed Fiber Switch 5.2.1 Installation and User Guide (04/06) 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Module The Magnum 6KP6-RJMST is a combo 6 port module of RJ-45’s at 10/100Mbps and fiber optic ports at 100MB. The Combo module is equipped with dualmode ST-type connectors and dual speed copper ports.
Magnum 6K25 Managed Fiber Switch 5.2.1b Installation and User Guide (04/06) 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module The Magnum 6KP4-F10ST 6KP4-RJ10MST, 4 Port@ 10Mb ST Fiber Port is a 10Mb multi-mode 2 fiber module with 4 STFiber ports. All four fiber ACT F/H ports are ST connectors and configured as 10Mb ACT F/H 1 TX LK RX 3 ACT F/H Half-duplex by default.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) duplex hub to connect to the switch through 10Mb fiber ports. Whereas the 100Mb ST module allow to connect the 100Mb demand of Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Singlemode for 10Km distance may be available as a special order).
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) The 6KP6-RJSSC, when installed in a Magnum 6K25 Switch operates on copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much as 25+ Km (see Power Budget, Section 4.5) Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connectivity with the remote device when lit, and a FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off).
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) proper connectivity with the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the LED is OFF. 5.2.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Halfduplex both. The functionality of this 100BASE-FX multi-mode 4 port module is essentially the same as the ST and SC-types. It has the same LEDs per port indicating port activity (ACT), Link (LK), and FDX or HDX operation 5.2.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) at half-duplex.The compact size of the LC Connector reduces the size of wiring panels in wiring closets while providing the advantage of “future-proof” fiber optic technology.The cable end is a “plug-in” connector with both fiber strands terminated in one housing that cannot be improperly inserted.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) and will allow both unshielded twisted pair (UTP) and shielded twisted pair (STP) cable connections. The 6KP8-RJ45 module is equipped with a Media Dependent AutoCrossover (MDI-X) switch, which controls all ports for cascaded connection. This feature eliminates the need for a special twisted pair crossover cable when connecting to a hub or another switch.
Magnum 6K25 Managed Fiber Switch • • • 5.2.11 port Installation and User Guide (04/06) devices. The PoE LED is ON when the attached PD is drawing power from the port. For non-PoE devices connected, the PoE port will act as a normal RJ-45 port and the PoE LED is OFF. No power is being sent out from the port.
Magnum 6K25 Managed Fiber Switch • • Installation and User Guide (04/06) and the PoE LED is OFF. No power is being sent out from the port. The PoE ports in Magnum 6K’s with 48VDC power input act as a passthrough, so the 48VDC power source must be strong enough to provide power to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to 15 watts per PoE port).
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) mode fiber ports. When installed in a Magnum 6K25 Switch, it supports the standard distances as mentioned on 5.2.4. and the LEDs also act similarly. 5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector equipped with SC type connectors and can be easily snapped in and out.
Magnum 6K25 Managed Fiber Switch 6.0 Installation and User Guide (04/06) TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation of a Magnum 6K25 Switch is a straightforward procedure (see INSTALLATION, Section 2.6); the operation is also straightforward and is discussed in Section 4.
Magnum 6K25 Managed Fiber Switch 6.2 Installation and User Guide (04/06) When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations when the problem occurs; c. The components involved in the problem; d. Any particular application that, when used, appears to create the problem; 2.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) GarrettCom reserves the right to charge for the testing of non-defective units under warranty. Testing and repair of product that is not under warranty will result in a customer (user) charge. 6.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) Input Voltage: 36 - 70 VDC Power Consumption: Same as for AC models (see Section 1.1) Power Supply (Internal 24 VDC Option) Industrial Applications DC Power Connector: 3 terminals: “-“, “GND”, “+” Input Voltage: 20 - 36 VDC Power Consumption: Same as for AC models (see Section 1.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) The 24VDC and 125VDC solution are particularly useful in the Industrial environment, where it is common facilities to operate on 24VDC or 125VDC power. The 125VDC solution is mainly used in power utilities, such as electrical substations, electrical generating plants, etc. The 24VDC applications are mainly in the Industrial environment, such as factory floor, HVAC equipment, military equipment, etc. B4.
Magnum 6K25 Managed Fiber Switch 5. 6. B5.0 Installation and User Guide (04/06) or equivalent. Fastening torque of the lugs on the terminal block: 9 inch-pound max. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rac,k at least 4 inches apart, with the first one located within 6 inches of the terminal block.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) APPENDIX C: Internal DC Dual-Source Power Option C1.
Magnum 6K25 Managed Fiber Switch C4.0 a) b) c) d) e) Installation and User Guide (04/06) FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw its power from the DC source with the highest voltage at a given time. The Switch unit will not allow power to flow from a higher voltage input to a lower voltage input, i.e. the two DC power sources are not mixed together by the hub.
Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06) C5.1 UL Requirements The following must be adhered to in order to conform to UL requirements: 1. Minimum 18 AWG cable for connection to a Centralized DC power source. 2. Minimum 14 AWG cable for connection to earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent. 5.