Magnum 6K8-Series Corporate Headquarters Industrial Field Switch GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Hardware Installation and User Guide www . GarrettCom . com www . GarrettCom .
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06) Magnum™ 6K8-Series Industrial Field Switch Hardware Installation and User Guide Part #: 84-00160 (Rev. A) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06) Table of Contents ........................................................................... Page 1.0 SPECIFICATIONS ............................................................................... 2 1.1 Technical Specifications ...................................................................... 2 1.2 Ordering Information ........................................................................... 5 2.0 Introduction.............
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06) 4.4 Flow-control, IEEE 802.3x Standard................................................. 43 4.5 Power Budget Calculations for Magnum 6K8-with Fiber Media ...... 43 5.0 Introduction - Magnum 6K8 Industrial Field Switch Port Modules45 5.1 Inspecting the Package and Product .................................................. 45 5.2 6KPMV Module Description............................................................. 45 5.2.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) THE MAGNUM LINE Ethernet connectivity products "Designed and Manufactured in the USA" Overview GarrettCom, Inc. offers the premium-quality Magnum™ line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary consideration.
Magnum 6K8-Series Industrial Field Switch 1.0 1.1 Installation and User Guide 03/06) SPECIFICATIONS Technical Specifications Performance Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet(1000Mb): 1, 488,000 pps Switching Processing Type: Store and Forward with IEEE 802.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Fiber Single-mode connector types: Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX Fiber Port, LC-type Fiber optic SFF single-mode, 100BASE-FX Fiber Port, 1000BASE-FX, GBIC modules LEDs: Per Port (one set at the port, one set on rear top) LK: Steady ON when media link is operational ACT: ON with receiver port activity FDX/HDX: ON = Full-Duplex Mode OFF = Half-Duplex Mode 100/10: ON = 100Mbps speed OFF = 10 Mbps Operating E
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) DC Power Supply (Options) -48VDC Power Input Voltage : -36 to -70 VDC 24VDC Power Input Voltage : 18 to 36VDC 125VDC Power Input Voltage : 88 to 300VDC 5VDC Power Input Voltage : (+) or (-) 5% Std.
Magnum 6K8-Series Industrial Field Switch 1.2 Installation and User Guide 03/06) Ordering Information Magnum Industrial Field Switch (8 ports max) MODEL DESCRIPTION Magnum 6K8 -Managed Industrial Field Switch, base unit for vertical mounting. Worldwide AC power. May be configured with a selection of 10/100/1000 fiber and copper port connector types, 8 total ports max. for 10/100Mbps or 2 ports maxm for Gigabit ports. Two metal brackets for vertical wall or panel mounting.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) “G+4” module, with one GBIC receptacle for one user selectable GBIC transceiver (see below) with 4 fixed 10/100 RJ-45 ports. 6KP3V-G2SC “G+2” module, with one GBIC receptacle for one user selectable GBIC transceiver (see below) and 2 100Mb 2km FX SC fiber ports. GBPMV-2OTX Two-port Gigabit module for 6K8-Series Switches, with two GBIC receptacles for user selectable GBIC transceivers (see below).
Magnum 6K8-Series Industrial Field Switch 2.0 2.1 Installation and User Guide 03/06) Introduction Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Magnum 6K8-Series Industrial Field Switch 2.2 Installation and User Guide 03/06) Product Description - Magnum 6K8-Series (6K8) The Magnum 6K8-Series, Industrial Field Switch is the smallest member of the Managed 6K-Switch family. It is equipped with one module slot configurable to 8ports. It is specially designed to meet industrial, power substation, and outdoor Ethernet specifications while fulfilling the needs of hardened applications.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) optimal cooling of internal components without any ventilation openings. This sealedcase design enables the unit to operate in temperature un-controlled environments, achieve high EMI noise immunity and provide an un-matched IP53 physical protection rating against dust, dirt, insects, and liquid spills. http://www.garrettcom.com/Pictorial/6k8_pictorial.pdf High performance features include non-blocking speed on all ports and 802.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) and traffic control systems, power utilities and industrial factory-floors. For the fast growing demands of video surveillance systems with segments requiring Gigabit backbone interconnections, the Magnum 6K8 managed switches are easy to install and operate with Magnum 6K management firmware.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) and controlled via hardware or software trap controls. The options for universal AC and 24V/-48V/125VDC power options offer a widely accepted managed switch with high reliability. 2.2.2 fiber Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb 1 3 5 7 ACT ACT F/H ACT F/H ACT F/H F/H LK LK LK LK ACT ACT F/H F/H ACT ACT F/H LK 2 4 LK LK 6 8 LK Fig.2.2.
Magnum 6K8-Series Industrial Field Switch 2.2.3 Installation and User Guide 03/06) Eight-Port Copper Module, 6K8-RJ45 The 6K8-Series’s 8-port Copper port module, model 6K8-RJ45, provides eight 10/100Mb switched RJ-45 ports. The 10/100Mb switched ports normally (as a default setting) are independently N-way auto-negotiating, and auto-crossover(MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode, i.e.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) (MDIX) features to eliminate the use of cross-over cables. The two fiber ports operate at 100Mbps full-duplex (default). User mode control per port through the MNS software is also the same. On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port, which indicate status as described for the 6K8-RJ45 in Section 2.2.3 above.
Magnum 6K8-Series Industrial Field Switch 2.2.6 Installation and User Guide 03/06) Gigabit (1000Mbps) port modules The Magnum 6K8-Series offers a wide range of optional Gigabit modules and one or two Gigabit ports can be configured in one modular slot. The Gigabit modules are the two port GBPMV-2OTX , the 6KP5V-G4RJ (single Gigabit+4 10/100 RJ-45 ports) or the 6KP3V-G2SC (single Gigabit+2 100Mb fiber ports) as shown below in the figure.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) The Magnum 6K8-Series switching hardware supports the IEEE 802.1p standard and fulfills its role in support of QOS, giving packet processing priority to priority tagged packets according to the 802.1p standard.
Magnum 6K8-Series Industrial Field Switch 2.2.9 Installation and User Guide 03/06) Managed Network Software ( MNS-6K ) for Magnum 6K8-Series Magnum 6K8-Series comes with licensed MNS-6K Firmware (Rel 3.2), which allows the configuration of the Magnum 6Ks as a Managed Switch and also allows other Software enabled features. For additional information about MNS-6K, see the Magnum 6K8-Series MNS Software User guide in pdf format, a separate document normally accessed via your web-browser, at ftp://ftp.
Magnum 6K8-Series Industrial Field Switch 2.3 Installation and User Guide 03/06) Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6K8-Series Switches provide non-blocking (all ports can run at full speed at once) performance with standard Managed Networks Software (MNS-6K) included. They are typically used in LAN traffic centers with 16 100Mb or 8+2 Gigabit ports for backbone connections, where managed network services are desired. Switching services includes 802.
Magnum 6K8-Series Industrial Field Switch 2.4 Installation and User Guide 03/06) Applications Magnum 6K8-Series Fiber Switches offer high performance, modularity and higher availability to provide an effective solution for Industrial Ethernet needs. They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit(1000Mb) ports, with industry-standard MNS-6K software.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) mount the 6K8 securely anywhere on their Network setup. The option for setting the ports at 10 or 100Mb on copper, and supporting the 10 or 100Mb fiber media, provide widespread options to the users to mix and match their legacy and advance network needs.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Example 2. In another outdoor Ethernet Traffic monitoring application, a managed network is needed to provide a Redundant ring topology for a maximum redundant network. This is needed where any faulty cable, cable disconnection or power failure in a ring switch needs to be reconfigured in milliseconds .
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Example 3: In another example, a large Power Substation (Electric and Gas) needs a Secure Ethernet LAN network to collect, monitor and provide a simplified communications backbone for local and remote control of real-time operational and fault analysis data. The Ethernet backbone should pass the information of SCADA local monitoring and control via a HMI. The heart of the system evolves around several communications processors.
Magnum 6K8-Series Industrial Field Switch 3.0 Installation and User Guide 03/06) Installation Before installing the equipment, please note the following UL/CSA60950 product safety listing requirements. 1)The external power supply for 24VDC units shall be a Listed, Direct Plug In power unit, marked Class 2, or a Listed ITE Power Supply, which has a suitably rated output voltage (i.e. 24VDC), and suitably rated output current.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) For AC power input, locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 6K8-Series site. The rugged metal case of the Magnum 6K8Series will normally protect it from accidental damage in a lab or workplace setting. Maintain an open view of the front to visually monitor the status LEDs. Keep an open area around the unit so that cooling can occur from convection while the unit is in operation.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) 3. Connect the Transmit (TX) port (light colored post) on the Magnum PM to the Receive (RX) port of the remote device. Begin with the color-coded strand of the cable for this first TX-to-RX connection. 4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit (TX) port of the remote device. Use the non-color coded fiber strand for this. 5. 3.2.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) unshielded and shielded twisted pair cables. 1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used. 2. Connect the other end of the cable to the corresponding device 3.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) floor enclosure, maintained vertically for proper convection cooling of the unit. The Magnum 6K8 requires two DIN-Rail mounting clips or latches for secure mounting, and these may be ordered as Model # DIN-RAIL-6K8. See a 6K8 viewed from the rear, at right, with model DIN-RAIL-6K8 in place on the unit. The Din Rail Latching clips are mounted on the upper rear corners of the 6K8 unit.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Fig 3.3 - Magnum 6K8 mounted vertically with DIN-Rail brackets and latches The DIN-Rail mounting brackets and latches are optional and need to be ordered as separate items, e.g Model # DINRAIL-6K8 3.3.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) a. The Din-Rail clip must be on top, while positioning the clip as shown in Fig. 2b with arrow mark. Fig. 2a: 10-32 Screws on indented side Fig. 2b: Din-Rail assembly w/plate applied to mount the Din-Rail assembly underneath. Remount the Din-Rail assembled plate onto the Magnum 6K8, using the 4-40 screws. Note: Torque 5lb/in max. on the 4-40 screws while tightening the screws. 5.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Fig . 3 3.3.2 Mounting Dimensions for 6K8 with metal brackets Each Mangum 6K8 is supplied with metal mounting brackets and screws to mount the unit securely. It is recommended to mount the 6K8 vertically, as shown below, for proper cooling and long-life reliability. It is also advisable to mount the unit with space for air movement around the top and the sides, typically a minimum of 1 inch..
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) The unit can be mounted using the brackets turned outside (normal) or inside (if space is tight). Attach the mounting bracket either outside or inside as shown in the illustration above (dotted line shown for the brackets inside). The spacing for the mounting screws into the supporting wall or panel is a rectangle 11.89” x 7.85” center-to-center. 3.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) high-availability communications and/or heavy industrial-grade applications, including: * -48VDC, 24VDC and 125VDC with single DC input, * -48VDC, 24VDC and 125VDC with dual-source DC input, See the Appendices B & C of this manual for more details. Use an RFQ for other variations. 3.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) referred to as “6KPMV” for convenience in describing port module installation. Magnum 6K8-Series Switches are normally received from the factory with all required 6KPMV modules installed. There may be situations where 6KPMV cards need to be added or replaced. In cases where additional 6KPMV cards are needed, the faceplate for an available front-mounted slot must be removed. The following procedure describes this operation.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) The Magnum 6K8-Series chassis consists of top cover and bottom chassis assembled together with the help of 12 Philips-head screws. There are 4 screws located on the top-side panel of the unit (2 each on both side), 8 for bottom chassis base of the unit. Remove these screws. Once these screws are removed, the top-cover is easily slide out to the front, off the chassis base, as shown in the picture above in Fig. 3.6.1a. Figure 3.6.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Once opened all the four retaining screws the front cover can be removed easily as shown in Fig 3.6.1d. on the left. Figure 3.6.1d: Removing Face Plate Carefully remove the PM screen plate using finger or small screw driver to come out easily as shown in Fig 3.6.1d on the right. Just be careful on the LEDs placed both side and hold the face plate tightly. There are no screws used on holding the screen face plate. Figure 3.6.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Figure below 3.6.2c, screw down tightly with the three 5/16 stand-off (male) on the top of the Granddaughter board. The three 5/16 stand off has been used to place the daughter board on the top of the granddaughter board and a latch connector to hold it securely. Fig 3.6.2b Granddaughter Female latch connector Board shown separately Fig 3.6.2c Granddaughter Board placed in slot & secured with three 5/16 standoff’s Step 3.
Magnum 6K8-Series Industrial Field Switch Step 5. Installation and User Guide 03/06) Once the latching connectors are aligned properly and the mounting holes are aligned with stand offs then press slowly and firmly with two fingers (as shown below in Fig. 3.6.2f) on the top of the latching connectors until the connectors latched up securely. Figure 3.6.2f: Securely latching up 6KPMV Cards into a Magnum 6K8-Series DSSV J5 Step 6.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) face plate with 4 screws to complete the installation process for port module. The front panel screen plate does not need any screws to hold on port module, but need to place tightly and carefully while placing on LEDs. Step 8. Once 6KPMV card have been installed (including faceplate and screen plate), the chassis cover should be replaced.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) underneath holding the Granddaughter board with the chassis. Figure 3.6.3a: 8 retaining screws shown by arrows Step 3. Remove 6KPM Card Carefully and gently pull out the daughter board from the latching connectors, using both hands, gripping the board near the latch-up connectors as shown in Fig. 3.6.3b Figure 3.6.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Magnum 6K8-Series Software Manual available on GarrettCom‘s FTP site. Please refer Section 2.2.9 of this manual for download information. 3.7.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.
Magnum 6K8-Series Industrial Field Switch 4.0 Installation and User Guide 03/06) OPERATION This chapter describes the functions and operation of the Magnum 6K8-Series Switch. 4.1 Switching Functionality A Magnum 6K8-Series provides switched connectivity at Ethernet wire-speed among all of its ports. The Magnum 6K8-Series supports10/100Mbs for copper media and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance.
Magnum 6K8-Series Industrial Field Switch 4.2 Installation and User Guide 03/06) Dual LEDs Status on TOP and Front of the 6K8-Series unit PWR/POWER : Power LED, ON when external power is applied to the unit. LK/LINK : Steady ON, Link status for 10 Mbps and 100Mbps operation. ACT : ON with port activity for 10 Mbps and 100Mbps operation. F/H : Full / Half duplex LED, ON when the port is running full duplex, OFF for half duplex.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) depending on the capabilities of the remote device. Standard commercially available Fast Ethernet media converters mostly do not support auto-negotiation properly, and require that the switched port to which they are connected be at 100Mb fixed speed. Attachment to 10/100 auto-negotiation ports typically will not work properly.
Magnum 6K8-Series Industrial Field Switch 4.4 Installation and User Guide 03/06) Flow-control, IEEE 802.3x Standard Magnum 6K8-Series Switches incorporate a flow-control mechanism for Full- Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full. This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) The following data has been collected from component manufacturer’s (Agilent’s and Lucent’s) web sites and catalogs to provide guidance to network designers and installers. Fiber Port Module Speed, 6KP4VF10ST 10Mb MultiMode FL Std. Mode Std. Wave Cable X’mitr R’cvr Worst Worst* typical typical* km Size Output Sens. OPB, distance OPB, distance fdx length µm dB Km, fdx PT , dB PR ,dB dB Km, fdx (hdx) nm 850 62.5/125 -15.
Magnum 6K8-Series Industrial Field Switch 5.0 Installation and User Guide 03/06) Introduction - Magnum 6K8 Industrial Field Switch Port Modules This chapter describes each Port Module (PM), including appearance, functionality, and status displays. 5.1 Inspecting the Package and Product This section applies only to PMs shipped as separate items, i.e., if 6K8 PMs not factory installed in a Magnum 6K8 PM slot.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) 5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Module The Magnum 6KP6-RJMST is a combo 6 port module of four RJ-45’s at 10/100Mbps and two fiber optic ports at 100MB. The Combo module is equipped with dual-mode ST-type connectors and dual speed copper ports.
Magnum 6K8-Series Industrial Field Switch 5.2.1b Installation and User Guide 03/06) 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module The Magnum 6KP4-F10ST 6KP4-RJ10MST, is a 10Mb multi-mode 4 Port@ 10Mb ST Fiber Port 2 fiber module with 4 STFiber ports. All four fiber ACT F/H ports are ST connectors and configured as 10Mb ACT F/H 1 TX LK RX 3 ACT F/H Half-duplex by default.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) half duplex hub to connect to the switch through 10Mb fiber ports. Whereas the 100Mb ST fiber module, allow to connect the 100Mb demand of Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km distance may be available as a special order).
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) network segments. The 6KP6-RJSSC, when installed in a Magnum 6K8-Series Switch operates on copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much as 25+ Km (see Power Budget, Section 4.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating proper connectivity with the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the LED is OFF. 5.2.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Halfduplex both. The functionality of this 100BASE-FX multi-mode 4 port module is essentially the same as the ST and SC-types. It has the same LEDs per port indicating port activity (ACT), Link (LK), and FDX or HDX operation 5.2.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) indicating packets being received, a Link (LK) LED indicating proper connectivity with the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). 5.2.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) feature eliminates the need for a special twisted pair crossover cable when connecting to a hub or another switch. Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connectivity with the remote device when lit, a FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a “10/100” LED indicating 100Mb when lit (or 10 Mbps when off).
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) 6KP8-45-2SLC 6KP8V 6 Port@ 10/100Mbps & 2 port @ 100Mbps The small sizes of LC connectors provide an advantage of placing Single-Mode Fiber port (LC) 2 more ports on one module. The 6KP8-45-2SLC is equipped with 6 1 10/100 RJ-45 ports and 2 Single4 mode fiber ports.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) 5.2.11a GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC Connector The Magnum GBIC-LXSC is a single-mode Gigabit fiber connector equipped with SC type connectors and can be easily snapped in and out. The Gigabit fiber ports are most popular as server-to-switch and switch-to-switch applications. It supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.
Magnum 6K8-Series Industrial Field Switch 6.0 Installation and User Guide 03/06) TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation of a Magnum 6K8-Series Switch is a straightforward procedure (see INSTALLATION, Section 2.6); the operation is also straightforward and is discussed in Section 4.
Magnum 6K8-Series Industrial Field Switch 6.2 Installation and User Guide 03/06) When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations when the problem occurs; c. The components involved in the problem; d. Any particular application that, when used, appears to create the problem; 2.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) GarrettCom reserves the right to charge for the testing of non-defective units under warranty. Testing and repair of product that is not under warranty will result in a customer (user) charge. 6.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) power input qualifies this product for use in 24VDC, -48VDC as well as 125VDC environments. The 24VDC, -48VDC or 125VDC power input provides an Ethernet networking product utilizing a special type of power supply with a proven highreliability record to fulfill the DC requirement.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) provides an Ethernet networking solution utilizing a special power supply in switches with a proven track record. Figure C5.0: -48VDC, wiring connections to the External Terminal Block on a Magnum 6K8 -48VDC The –48VDC solution is particularly useful inthe telecommunication industry, where it is common for facilities to operate on -48VDC power.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) so the user may elect to Ground either + or = terminal to suit the customer’s use. Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”. B4.1 1. 2. 3. 4. 5. 6. B5.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-125V) DC Power Connector: First Source: “A+”, “A-“, 2nd Source “B-“, “B+” GND: Terminal for “earth” or ground wire connection to the hub chassis Input: Two separate sources, each at 88 - 300 VDC With the exception of the dual DC input power connections and the power supply, all specifications and configuration options for the Magnum 6K8-Series -48VDC, 24VDC and 125VDC mod
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) because of the blocking action of the diodes. This is true even if one input connection is reversed while the Switch is operating from the other source. e) The Switch will not receive power (and will not work) when both inputs are simultaneously absent or are both incorrectly connected. C5.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06) 6. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block. C6.0 ORDERING INFORMATION (Optional) To order the optional Dual-Source -48VDC power supply factory installed, order “Dual-Src48V” as a separate line item following the product model.