Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Magnum 6KQ Managed Field Switch Hardware Installation and User Guide www . GarrettCom . com www . GarrettCom .
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) Magnum™ 6KQ Managed Field Switch Hardware Installation and User Guide Part #: 84-00180Z (Rev. A) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) Table of Contents.............................................................................. Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications ...................................................................... 1 1.2 Ordering Information ........................................................................... 4 2.0 Introduction......................
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) 5.2.2. 5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 5.2.8 5.2.9 6KQF-2MSC Fiber connector .................................................... 37 6KQF-2SSCL FX-SC-type, Sgl.M ........................................... 37 6KQ3-RJMSC “COMBO” connector ....................................... 38 6KQ4-MT MTRJ Small-Form-factor ......................................... 38 6KQ4-RJMT, “COMBO” multi-mode FX , MTRJ Small-FF ... 39 6KQ4-MLC LC connector SFF .......
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) THE MAGNUM LINE Industrial networking products "Designed and Manufactured in the USA" Overview GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUM™ LINE OF INDUSTRIAL CONECTIVITY PRODUCTS WITH INDUSTRY-STANDARD FUNCTIONALITY AND BUILT-IN FIBER CONFIGURABILITY. MAGNUM PRODUCTS ARE DESIGNED FOR USE IN DEMANDING INDUSTRIAL GRADE, CARRIER CLASS, POWER UTILITY AND OEM APPLICATIONS WHERE RELIABILITY IS A PRIMARY CONSIDERATION.
Magnum 6KQ Managed Field Switch Installation and User Guide 1.0 1.1 (04/07) SPECIFICATIONS Technical Specifications Performance Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet (1000Mb): 1, 488,000 pps Switching Processing Type: Store and Forward with IEEE 802.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km Fiber Multi-mode connector types supported: Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX Fiber Port, ST-type (twist-lock): Fiber optic m.
Magnum 6KQ Managed Field Switch Installation and User Guide 12 watts typical (for a small 4 port copper-only model) (04/07) DC-DUAL POWER SOURCE (OPTIONAL) For DC internal power supplies at –48VDC, 24VDC and 125VDC, with the Dual-Source option (for continuity of operation when either of the DC input sources are interrupted), see Appendices B and C. Dual-Source Terminal Block : “ –A, -B, +A, +B ” 6KQ Mounting: Vertical mounting normal.
Magnum 6KQ Managed Field Switch Installation and User Guide 1.2 (04/07) Ordering Information Magnum Managed Field Switch (16 ports max) MODEL DESCRIPTION Magnum 6KQ- 24VDC Magnum 6KQ Managed Field Switch, base unit with 24VDC power supply and four 10/100 copper ports. May be configured with a selection of 10/100/1000 fiber and copper port connector types from a family of 6KQ port modules per the 6KQ configuration guide, 16 total ports max. Heavy duty and environmentally hardened, no fans.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 6KQF-4MT “4 ports” module, w/four 100Mb mm 2km FX MTRJ’s fiber ports 6KQF-4MLC “4 ports” module, w/four 100Mb mm 2km FX LC’s fiber ports 6KQF-4SLC “4 ports” module, w/four 100Mb Sm, 15km FX LC’s fiber ports 6KQF-2MST “2 ports” module, w/two 100Mb mm, 2km FX ST’s fiber ports 6KQF-2MSC “2 ports” module, w/two 100Mb mm, 2km FX SC’s fiber ports 6KQF-2SSC “2 ports” module, w/two 100Mb Sm, 20km FX SC’s fiber ports 6KQF-2SSCL “2 ports” module, w/t
Magnum 6KQ Managed Field Switch Installation and User Guide 2.0 2.1 (04/07) Introduction Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Magnum 6KQ Managed Field Switch Installation and User Guide 2.2 (04/07) Product Description - Magnum 6KQ Field Switch Magnum 6KQ Managed Field Switches provide maximum configurability in their class. The fiber-rich 6KQ can be configured with up to 12 100Mb fiber ports and two Gigabit ports. For 10/100 copper, regular or PoE-equipped 10/100 RJ-45 or 10/100/1000 copper ports may be configured to a maximum or 12 at 10/100 and 2 Gig ports.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The 6KQ managed switches also provide PoE options via power – inside PoE modules on one of A, B or C slots and allows the users to select a wide option of combo PoE modules to support 802.3af pd devices. See details for PoE modules in sec 5.2.10. The Power Sourcing Equipment (PSE) is fully compatible with Powered Devices (PD)(e.g wireless access points, IP phones) that comply with the IEEE 802.3af PoE standard.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Alarm Relay contacts provided on each Magnum 6KQ Switch monitor the hardware and software through traps, providing a record of any losses of power signals and other userdefined software events. See Section 3.5 for details. The wide selections of Quad port (queen size) modules are key to the flexibility and adaptability of Magnum 6KQs. Some of the popular 4 ports modules are described below.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) on the port. A fiber cable must be connected into a SFF port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port. 2.2.2 Four-Port Copper Module, 6KQ4-RJ45 The 6KQ’s 4-port Copper module, model 6K4-RJ45, provides four 10/100Mb switched RJ-45 ports.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) dependent upon the -48VDC input power to supply the PD power for these RJ-45 (10/100) ports. Each port supplies up to 15watts to power the PoE PD devices. A maximum of 8 PoE ports can be configured in the A and B slots of a 6KQ switch with 48vdc power input. The PoE modules are also available with mix–n-match fiber modules configured in other 6KQ slots. Please check the Configuration Guide and the ordering information Sec.1.
Magnum 6KQ Managed Field Switch Installation and User Guide 2.2.5 (04/07) Two -Port 10 Mb mm Fiber ST Modules The 2-port @10Mb ST fiber modules behave the same as the 2@100Mb ST fiber modules except for the 10Mb speed. The default setup on the 10Mb fiber module is half-duplex, which allows the Magnum 6KQ Switch to connect to any 10Mb hub or media converter or almost any other device with a 10Mb fiber Ethernet port. The default setting of the 100Mb fiber module is full duplex.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) There are three LEDs mounted on each Gigabit port module. The Gigabit fiber has LEDs that indicate F/H (Full/Half duplex), LK (Link status) and ACT (receiving activity) on that port when lit. The copper Gigabit ports come with speeds indicating (10/100/1000Mb) LEDs also. The operation of the Gigabit SFP and 10/100/1000 RJ-45 ports is as described for those port types above.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) load is greatest. When the Magnum 6KQ Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices sending it packets to cause “flow control”. This tells the sending devices to temporarily stop sending traffic, which allows the traffic to catch-up without dropping packets. Then, normal packet buffering and processing resumes.
Magnum 6KQ Managed Field Switch Installation and User Guide 2.3 (04/07) Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6KQ Switches provide unicast non-blocking (all ports can run at full speed at once) performance with standard Managed Network Software (MNS-6K) included. They are typically used in LAN traffic centers with up to 12 100Mb +2 Gigabit ports for backbone connections, where managed network services are desired.
Magnum 6KQ Managed Field Switch Installation and User Guide 2.4 (04/07) Applications Magnum 6KQ Field Switches offer high performance, modularity and availability. They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit (1000Mb) ports, with industry-standard LAN management software.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) fiber media provide widespread options to the users to mix and match their legacy and advance network needs. The modularity of the 6KQ Managed Field Switches make them an attractive choice for use in applications with LAN connections to an organization’s multiple site offices and factory- floors. The different locations can be easily connected together with the Fiber ports supported by the Magnum 6KQ Switch.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) power failure can bring the whole thing down, a ring switch can be reconfigured and up and running in milliseconds. The ring topology of the network consists of high speed LAN segments supported by 100Mbps full-duplex future-proof fiber media to provide a secure long distance LAN connection. The entire network is sharing a higher bandwidth Gigabit-enabled data-mining server for the vital database located in a separate secured building.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Example 3. In another application in an industrial environment, a 12 port Nebs compliant, -24VDC managed switch is required to meet the fiber and copper connections to cover the wider area of video CCTV. The switch must be SNMP enabled and managed to easily monitor the whole setup. The Magnum managed field switch easily qualifies for this requirement with the various features and modularity it has.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) For DC power input data, see Appendix B. For Dual Source, see Appendix C . The rugged metal case of the Magnum 6KQ will normally protect it from accidental damage in a lab or workplace setting. Maintain an open view of the front to visually monitor the status LEDs. Keep an open area around the unit so that cooling can occur from convection while the unit is in operation. The 6KQ has no fans, so it is silent when in operation.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting. Note: One strand of the duplex fiber optic cable is coded using color bands at regular intervals; you must use the color-coded strand on the associated ports at each end of the fiber optic segment. 3.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) NOTE : It is recommended that high quality CAT. 5 cable be used whenever possible in order to provide flexibility in a mixed-speed network, since 10/100 copper switched ports are auto-sensing for either 10 and 100Mb/s. 1. 2. 3. The following procedure describes how to connect a 10BASE-T or 100BASETX twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted pair cables.
Magnum 6KQ Managed Field Switch Installation and User Guide 3.2.6 (04/07) Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for both telecommunication and data communications applications. Due to its compact, hot pluggable characteristics, SFPs are becoming a very popular choice for various applications.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The various SFPs transceivers supported by GarrettCom 6KQs D slot are- Module Model# Gigabit Gb Modules, fixed ports--SFP 6KQ-2GSFP 2 SFP 6KQ-2GCU 2 CU 6KQ-2GSFPCU 1SFP, 1CU 6KQ-1GSFP 1 SFP 6KQ-1GCU 1 CU Gb SFP fiber optic transceivers SFP-SX Gb SX, 850nm wavelength, 500 m distance SFP-LX10 Gb LX, 1310nm wavelength, 10km dist SFP-LX25 Gb LX, 1310nm wavelength, 25km distance SFP-ZX40 Gb ZX, 1550nm wavelength, 40km dista
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) fiber optic segment. 3. Find the Transmit (TX) and Receive (RX) markings on the SFP transceiver to verify the top side of it. Some of the transceiver marks arrow sign for up. 4. Position the SFP transceiver correctly before insertion, and then insert the SFP transceiver carefully, until the transceiver connector snap into the place in the socket connector. 5.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The Din Rail Latching clips are mounted on the upper side corners of the 6KQ unit. Two threaded holes are provided on the sides of 6KQ for DINRail mounting purposes. See side view at the left. The required two screws are included with the DIN-Rail brackets, and are no.10-32 X 3/8 PHIL. PAN w/star washer.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) air circulation and cooling of the rear part of the case. For best cooling of the 6KQ, attach the metal brackets to metal (rather than wood or plastic). Attaching to metal helps conduct heat away from the 6KQ through the metal brackets and into the metal support structure.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) consumption will range from about 20 up to 35 watts, depending on the port quantity and types in the configuration.. When connecting the Ethernet cabling, there is no need to power down the unit. Individual cable segments can be connected or disconnected without concern for power-related problems or damage to the unit.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The Alarm Contacts are on the front left area (next to the DC power source) of the Magnum 6KQ unit and are green in color as shown in the picture. 3.6 6KQ Port Module (6KPM) Installation Magnum 6KQ Switches are normally received from the factory with all required 6K Port Modules installed. NOTE: There may be situations where the 6K PMs need to be added or replaced.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The Hyper terminal configuration is exactly the same as all other 6K-Family managed switches. Please check the following URL for details- http://www.garrettcom.com/techsupport/software/userguides/mns6k_CLI.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) to the other ports where it is not needed. Traffic needed for maintaining the uninterrupted operation of the network (such as occasional multi-cast packets) is forwarded to all ports. The Magnum 6KQ Switches operate in the store-and-forward switching mode, which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) this manual to access the “6K-MNS(Rel 3) Software user guide” One frequently-used application for the Managed Magnum 6KQ Switch copper ports is to connect one of them using a fiber media converter to another Switch in the network backbone, or to some other remote 100Mb device. In this case, it is desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode depending on the capabilities of the remote device.
Magnum 6KQ Managed Field Switch Installation and User Guide • (04/07) NOTE – Some NIC cards only auto-negotiate when the computer system that they are in is powered. These are exceptions to the “negotiate at LINK – enabled” rule above, but may be occasionally encountered. When operating in 100Mb half-duplex mode, cable distances and hop-counts may be limited within that collision domain. The Path Delay Value (PDV) bit-times must account for all devices and cable lengths within that domain.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km, and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25) and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (LXSC40) and the “Cable Loss” for 9/125 (Single-mode) is 0.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the full-duplex (factory default) setting for 100Mbps fiber ports must be used, and • The worst-case OPB of the fiber link must be greater than the fiber cable’s passive Attenuation. (Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor) 5.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Note: The 6KQ Port modules are not identical to the port modules used in other 6K products such as the 6K25e and 6K16V. For information about other 6K products, please see the applicable manual. For a list of 6KQ Port Modules, refer to Section 1.2 Each 6KQ Port Module (PM) is individually described in the following sections. 5.2.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-duplex and halfduplex. Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connectivity with the remote device when lit, and an FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). 5.2.2.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 5.2.4 6KQ3-RJMSC “COMBO” 2@ 10/100Mbps RJ-45 Ports and 1@100Mbps Multi-mode 6KPQ3 -RJMSC FX-SC-type, “snap-in” 2 Port@ 10/100Mbps & 1 port @ 100Mbps connector The Magnum 6KPQ-RJMSC MultiMode Fiber port 1 2 is also a Combo module LK/ACT 10/100 100Mb ACT equipped with 2 dual speed F/H F/H ACT copper ports and 1 Multi-mode 4 SC-type connector.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The functionality of this 100BASE-FX multi-mode 4-port module is essentially the same as the ST and SC-types. It has 6KQ4-RJMT the same LEDs per port indicating port 2 Port@ 10/100Mbps & 2 port @ 100Mbps MTRJ Fiber port 2 1 activity (ACT), Link (LK), and FDX or HDX operation. LK/ACT 10/100 100Mb ACT F/H F/H 5.2.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The cable end is a “plug-in” connector with both fiber strands terminated in one housing that cannot be improperly inserted.
Magnum 6KQ Managed Field Switch Installation and User Guide “10/100” LED indicating 100Mb when lit (or 10 Mbps when off). (04/07) Note: The 10/100 RJ-45 ports are supported with Auto-negotiation and Autocrossover (MDIX), which allow the RJ-45 ports to automatically Link with any RJ-45 device and eliminate the use of cross-over cable.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 6KQ-2GSFPCU 1 Port@ 10/100/1000Mbps, 1 Port at 1000Mb SFP 2 4 1 3 1 3 5.2.11 LINK ACTIVITY 2 10/100/1000 4 FULL/HALF SFPs, Gigabit (1000Mbps) port modules The Magnum 6KQ offers a Gigabit option with multiple choices of copper 10/100/1000Mbps or Gigabit SFP Fiber modules for the modular slot. While up to two Gigabit modules (maxm.) can be configured in the modular slot D only.
Magnum 6KQ Managed Field Switch Installation and User Guide 5.2.12 (04/07) 6KQ-BLNK The 6KQ-BLNK is a blank face plate or cover plate that must be installed in any empty 6KQ PM slot to maintain proper cooling air flow, safety, etc. Two screws underneath the front panel hold the 6KQ-BLNK in place. 6.0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments.
Magnum 6KQ Managed Field Switch Installation and User Guide 6.2 1. 2. 3. 4. 6.3 (04/07) When Calling for Assistance Please be prepared to provide the following information. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations when the problem occurs; c. The components involved in the problem; d.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection. ( You may retain all connectors and this Installation Guide.) CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the unit. 2.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) APPENDIX B : DC Power Input B1.0 Specifications for Magnum 6KQ Switches, DC Power at 24V and – 48V and 125V DC Power input Each Magnum Model 6KQ Managed Switch requires DC power input, at either 24VDC, -48VDC or 125VDC nominal. The wide range of DC power input types qualifies this product for use in 24VDC, -48VDC as well as 125VDC applications in different industries.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) other communication companies. In addition, many high availability equipment services, such as broadcasters, publishers, newspaper operations, brokerage firms and other facilities often use a battery backup system to maintain operations in the event of a power failure. It is also frequently used for computer system backup, management and operations monitoring equipment.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) secure the cable to the rac,k at least 4 inches apart, with the first one located within 6 inches of the terminal block. B5.0 OPERATION Operation of Magnum 6KQ Switches with the optional -48VDC, 24VDC and 125VDC dual-source power input is identical to that of the standard single-source DCpowered models. B6.0 TROUBLESHOOTING Please refer to Section 6.0 for troubleshooting APPENDIX C: Internal DC Dual-Source Power Input Option C1.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION The Dual-Source DC power A+ HUB option is designed using diodes inside SUPPLY A+ of the chassis on each DC power input line. A diode is placed in each of the Bfour input lines (behind the four B+ external power connection terminals) CHASSIS GND GND so that power from an external source can only flow into the unit.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”. The connection procedure is straightforward. Simply connect the DC leads to the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely tightened. C5.