32
Fiber Cable Type cable diameter * Max. length Wavelength
Multi-mode fiber 50/125, 62.5/125, 2km 850 nm
80/125, 100/140 ** (see next page)
Single-mode fiber 2/15 - 8/60 10km 1300 nm
* xx/yy are the diameters of the core and the core plus cladding respectively
** The values shown are typical values
Procedure for connecting multi-mode and single-mode fiber cables:
1.
Before connecting the fiber cable, remove the protective dust caps from the tips of
the connectors on the media converter. Save these dust caps for future use.
2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue
dampened in alcohol. Make certain the connectors are clean before connecting.