Magnum 200X Two-Port Repeaters Corporate Headquarters Garrett Communications 213 Hammond Avenue Fremont, CA 94539 Phone (510) 438-9071 FAX (510) 438-9072 WWW: http://www.garrettcom.com email: support@garrettcom.
Magnum 200X Two-Port Repeaters Installation and User Guide (04/99) Magnum 200X Two-Port Repeaters Installation and User Guide Part #: 84-00022 (R04/99) Trademarks Ethernet is a trademark of Xerox Corporation Velcro is a trademark of Velcro U.S.A. UL is a registered trademark of Underwriters Laboratories Magnum is a trademark and Personal Hub is a registered trademark of Garrett Communications, Inc. Important: Magnum 200X Two-Port Repeaters contain no user serviceable parts.
Magnum 200X Two-Port Repeaters Installation and User Guide (04/99) Contacting Garrett Communications Please use the mailing address, phone and fax numbers, and Internet address listed below. Garrett Communications 213 Hammond Avenue Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 WWW: http://www.garrettcom.com email: support@garrettcom.
Magnum 200X Two-Port Repeaters TABLE OF CONTENTS Installation and User Guide (04/99) PAGE 1.0 SPECIFICATIONS............................................................................................................1 1.1 Technical Specifications............................................................................................1 1.2 Specifications - Repeater Port Module (RPM) ......................................................3 1.3 Ordering Information..........................................
Magnum 200X Two-Port Repeaters Installation and User Guide (04/99) The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW Garrett Communications offers the Magnum line of Ethernet LAN connectivity products with industry-standard functionality. Magnum products are available worldwide through OEMs, network integrators, representatives, and international distributors.
Magnum 200X Two-Port Repeaters Installation and User Guide (04/99) Workgroup Bridges, 10Mb series Fan-Outs, 10Mb series 4 and 8 Port Deluxe, 2 and 4 Port Standard Models Transceivers, 10Mb series Mini-Transceivers and Coax Models, All Types GARRETT April’ 99
Data Rate: 10 Mbits / sec Partitioning: Enforced after 32 consecutive collisions. Reconnect: Occurs after 512 bits of error-free transmission. Network Standards Ethernet V 1.0/V2.0 IEEE 802.3: 10BASE-T, 10BASE5, 10BASE2, 10BASE-FL & FOIRL, and DTE (The Magnum 200X Two-Port Repeaters are physical layer standard Ethernet products, and operate independently of all software.
Ambient Temperature: 32° to 120° F (0° to 50°C) Storage Temperature: -5° to 140°F (-20°to 60°C) Ambient Relative Humidity: 10% to 95% (non-condensing) Packaging 200X: Enclosure: High strength steel. Suitable for wiring closet shelf or desktop mounting. (Rack-mount brackets are available as an option) Repeater Port Module Slots: 2 Dimensions: 5.4 in D x 8.5 in. W x 1.75 in. H (13.7 cm x 21.6 cm x 4.45 cm) Weight: 2.5 lbs (1.1 Kg) Port Slot Cut-out: 2.2 in. x .75 in. (5.6 cm x 1.
Warranty Three years, return to factory Made in USA 1.2 Specifications - Repeater Port Modules (RPMs) RPM Type : BNC AUI DTE Fiber-mm Fiber-sgl.m TP* Front Access yes yes yes yes yes yes Connector Type BNC-f DB-15 f DB-15 m Fiber-ST Fiber-ST RJ-45 Partitio n (PART)LED yes yes yes yes yes yes Receive (RX) LED yes yes yes yes yes yes LINK LED n.a. n.a. n.a. yes yes yes Switch on Face Plate yes** n.a. n.a. n.a. n.a. yes*** “Fiber-mm” is multi-mode cable, normally used for 10BASE-FL installations, up to 2.
Magnum 200X-AT 1 AUI and 1 TP port Magnum 200X-T T 2 TP ports Magnum 200X-BF 1 BNC and 1 fiber port Magnum 200X-AF 1 AUI and 1 fiber port Magnum 200X-TF 1 TP and 1 fiber port Magnum 200X-FF 2 fiber ports Magnum 200X Spare Parts Magnum 200X Magnum RPM-BNC 1slot Magnum RPM-TP Magnum RPM-AUI Magnum RPM-DTE Magnum RPM-FST Magnum RPM-FSM Note: Base chassis with 2 RPM slots, internal auto-ranging P.
Remove the items from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. To validate the product warranty please complete and return the enclosed Product Registration Card to Garrett Communications as soon as possible. In the event there are items missing or damaged, contact the party from whom you purchased the product. If the unit needs to be returned, please use the original shipping container if possible.
Module (RPM) to provide either 10BASE2, 10BASE5, 10BASE-FL, FOIRL, or 10BASE-T connectivity. The individual RPMs are used for one Ethernet segment each, and provide full IEEE 802.3 repeater functionality supporting a full length segment. Individual RPMs are equipped with a single media interface connector. Any RPM can be installed in either slot of the Magnum 200X eu PWR RX COL JAB Magnum 200X chassis. GARRETT Figure 2.2.
Magnum RPM Cards : RPM-BNC, RPM-AUI, RPM-DTE RPM-FST, RPM-FSC, RPM-TP Each of the individual RPMs are described in detail in this section. NOTE: Due to the larger physical size of the Magnum Bridge Port Modules (BPMs), the standard Magnum 200X cannot be configured with a BPM. A physically larger 200X chassis is available by special order. As an alternative, the Magnum 30X Workgroup Bridge, is available in five standard configurations for bridge-isolating a workgroup segment to improve performance.
2 10BASE2 coax connector. This RPM performs full IEEE 802.3 Receive LED 1 2 repeater functionality and is used for 10BASE2 ThinNet Magnum RPM-BNC (commonly referred to as BNC) connections. The RPM-BNC module is designed with a special switch -selectable internal termination function that eliminates the need for a "tee" connector and a 50 ohm terminator. To take advantage of internal termination, the slide switch should be in the "DOWN" (or right-side) position.
the need for a special twisted pair 2 crossover cable. With the switch in 3 the UP (or LEFT) position, the RPM- 1 LINK 2 Partition 3 Receive TP port is used for up-link connections (i.e., a connection to another repeater or hub typically.) Magnum RPM-TP When used for segments going to workstations and other user device connections, the switch should be in the DOWN (or RIGHT) position. The LINK LED is particularly useful in choosing the proper position for the up-link switch.
IEEE 802.3 repeater functionality. It is used to provide connectivity with 2 1 a 10BASE5 (ThickNet) backbone or to any AUI segments. A transceiver is required when connecting to a Magnum RPM-AUI ThickNet segment and the RPMAUI supports this convention. The RPM-AUI is also a "universal" Ethernet media interface as it may be used with a variety of different mini-transceivers to provide connectivity to any media type.
6 7 8 9 NOTES: Voltage Common 15 Control Out Circuit B Control Out Circuit A SHELL Protective Ground Control Out Circuit Shield (conductive shell) Control In Circuit B 1) 2) 2.3.4 Voltage Plus (pin #13) and Voltage Common (pin # 6) use a single twisted pair in the AUI cable. Pins 4, 8, 11 and 14 may be connected to pin #1. RPM-FST (Fiber ST, Twist-lock Connector) The Magnum RPM-FST is a multi- 10BASE-FL, FOIRL ST Connectors mode fiber optic module equipped with a dual STtype connector.
When distances of less than 2 km are needed, the jumper should be placed across pins 1 and 2. J1 * When fiber cable distances of more than 2 km are selected, the minimum cable length must also be increased, as shown in the table above. 2.3.5 RPM-FSC (Fiber SC, Snap-in Connector) The Magnum RPM-FSC is also a multi-mode fiber optic repeater module, similar to the RPM -FST.
is only to be placed across pins 5 & 6. Others are not used. JUMPER ACROSS DISTANCES SUPPORTED 1-2 0 - 10 km 3-4 not used 1 2 5-6 not used 3 4 5 6 J1 DEFAULT Note: Be sure to use single-mode fiber optic cable with this module. Single-mode fiber has a smaller diameter than multi-mode fiber (2/15 - 8/60 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode, where xx/xx are the diameters of the core and the core plus the cladding respectively). 2.3.
Users may expand network distances while retaining the media of choice with these models. n Six Models for Mixed Media Since the Magnum 200X port connectors are modules, the units are ideal when different media types need to be brought together at a repeater unit. Two-Port models are available with all combinations of BNC, AUI, TP, and Fiber.
of homogeneous-media repeater models support each standard Ethernet media type, and allow users to expand network distances while retaining the wiring media of choice. As many as four repeaters may be connected in series to connect users at the extremities of 5X the standard segment distance while still adhering to the Ethernet "four repeater" rule. 10BASE2 (BNC) Segment - + PWR [12VDC, 1A] Magnum 20X Two-Port Repeater GARRETT 10BASE2 (BNC) Segment Figure 2.5.
convenience outlet for a simple installation. For rack-mounting, two 200X units fit side-byside in a standard rack-width space. (Rack-mounting brackets for 200Xs may be optionally purchased, see the Magnum Spare Parts Price List. The same brackets fit the Magnum 200X Repeaters and the Model 1008 Workgroup Hubs). The Magnum 200X units are suitable when network segment extensions are needed in offices, labs, hallways and storage areas.
3.1 Locating the Magnum 200X Two-Port Repeater The location of the Magnum 200X Two-Port Repeater is dependent on the physical layout of the network and the area to be served. The unit should be set-up in a location that will accommodate easy and equal access to planned network devices and/or segment connections. Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 200X repeater site.
Fiber (mm1 ) FOIRL ST or SMA RPM-FST, RPM-FSM, BPM-FST Fiber (mm1 ) Fiber (sgl.m2 ) 10BASE-FL ST or SMA * ST RPM-FST, RPM-FSM, BPM-FST RPM-SMF 1 mm = multi-mode sgl.m = single-mode * not currently standardized by IEEE 2 3.3.1 Connecting Twisted Pair (RJ-45, Unshielded or Shielded) The following procedure describes how to connect a 10BASE-T twisted pair segment to the RJ-45 port on the RPM-TP. The procedure is the same for both unshielded and shielded twisted pair segments. 1.
3.3.3 Connecting ThickNet 10BASE5 (AUI) Using the steps below as a guide, attach a new or existing 10BASE5 ThickNet drop- cable directly to the AUI connector on the RPM-AUI port. 1. Plug the male end of the cable into the female AUI connector on the RPMAUI card. 2. Engage the AUI connector slide lock to insure maximum connectivity. 3. Connect the opposite end of the cable into a network AUI port.
3. 4. 5. 3.3.6 Connect the Transmit (TX) port (light colored post) on the Magnum RPM-FST to the Receive (RX) port of the remote device. Begin with the color-coded strand of the cable for this first TX-to-RX connection. Connect the Receive (RX) port (dark colored post) on the RPM-FST to the Transmit (TX) port of the remote device. Use the non-color coded fiber strand for this.
all required RPM modules and media connectors installed. There may be cases where a different RPM connector is desired, making it necessary to exchange one RPM type for another. The replacement procedures described inthe next two sections should only be performed by a trained technician. 3.4.1 Exchanging RPMs in the Magnum 200X STOP!!! Be sure the power cord is unplugged from the chassis before attempting to remove and/or replace an PM card.
eu PWR RX COL JAB Each RPM is secured to the front of the GARRETT 200X chassis with two screws. Once these RPM retaining screws screws have been removed, the RPM can be Retaining screw removal easily lifted out of the unit. 4. PM Retaining Screw Hole RPM Card Installation PM Mounting Plate Hold the card parallel to the bottom of the 200X, with the RPM media connector Media Connector facing the front of the unit, and the RPM connector pins facing to the right.
This section describes the functionality and operation of the Magnum 200X TwoPort repeaters. 4.1 Repeater Functionality The Magnum 200X units operate as mixed-media or homogeneous Ethernet repeaters. Both types are compliant with IEEE 802.3 specifications and supports all IEEE defined media, including 10BASE-T, 10BASE-FL, FOIRL, 10BASE2, and 10BASE5. The following describes the basic functionality of the Magnum 200X Two-Port Repeaters. 1.
between 47 and 63 Hz, and will consume no more than a maximum of 15 watts. The power connector is located on the back of the unit. In order to power down the unit, simply unplug the power cable from either the wall socket, power strip or the power connector on the back of the unit. When connecting various Ethernet media, there is no need to power down the unit.
operation is also straightforward and is discussed in Section 4.0. Should problems develop during installation or operation, this section is intended to help locate, identify and correct these types of problems. Please follow the suggestions listed below prior to contacting your supplier.
b. Situations when the problem occurs c. The components involved in the problem d. Any particular application that, when used, appears to create the problem 2. An accurate list of Garrett Communications equipment model(s) with serial number(s). Include the date that you purchased the equipment. 3. It is useful to include other network equipment models and related hardware, including personal computers, workstations, terminals and printers; as well as the various network media being used. 4.
Should you need to ship the unit back to Garrett Communications, please follow the these instructions: 1. Package the unit carefully. It is recommended that you use the original container. Units should be wrapped in a "bubble-wrap" plastic sheet or bag. Retain all of your cables and connectors, and this Installation Guide. CAUTION Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the unit. 2.
B1.0 SPECIFICATIONS - FOR MAGNUM 210X TWO-PORT REPEATERS Power Supply (Internal 48 VDC Option) DC Power Connector: 3 terminals: “- “, “GND”, “+” Input Voltage: 36 - 70 VDC (auto-ranging) Power Consumption: Model 210X: 8 watt typical, 15 watts max. _ GND With the exception of the power supply, all specifications and functions of Magnum 210X-48VDC models are identical to Magnum 200X listed in the main manual. B2.
This section describes the installation of the 48 VDC power source leads to the 48 VDC power terminal block on the Magnum 210Xs. (see figure below). Figure B4.1: 48 VDC Terminal Block on _ GND + Magnum 210X-48VDC The 48 VDC terminal block on the Magnum 210Xs is located on the front of the unit and is equipped with three (3) screw-down lead 36-70VDC posts. The leads are identified as negative (-), positive (+), and chassis ground (GND). The actual connection procedure is very straightforward.