Corporate Headquarters GarrettCom, Inc. Magnum IPS42 Internal Power Supply for Edge Switch Family 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support@garrettcom.com Installation and User Guide www . GarrettCom . com www . GarrettCom .
IPS42 Internal Power Supply Installation and User Guide (11/09) Magnum™ IPS42 Internal Power Supply for Edge Switch Family Installation and User Guide Part #: 84-00181Z Rev. B Trademarks GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch are trademarks of GarrettCom, Inc.
IPS42 Internal Power Supply Installation and User Guide (11/09) Important: The Magnum IPS42 Series Internal Power Supply for Edge Switches contains no user serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. If problems are experienced with Magnum IPS42 Internal Power Supply products, consult Section 4, Troubleshooting, of this User Guide. Copyright © 2009 GarrettCom, Inc. All rights reserved.
IPS42 Internal Power Supply Installation and User Guide (11/09) Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication.
IPS42 Internal Power Supply Installation and User Guide (11/09) Electrical Safety requirements: 1. This product is to be installed Only in Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets, or the like). 2. 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product. 3.
IPS42 Internal Power Supply Installation and User Guide (11/09) Contacting GarrettCom, Inc Please use the mailing address, phone, fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support@garrettcom.com www . GarrettCom .
IPS42 Internal Power Supply Installation and User Guide (11/09) TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications ...................................................................... 1 1.2 Summary of models and descriptions for IPS42 Series: ...................... 5 2.0 INTRODUCTION ................................................................................. 8 2.
IPS42 Internal Power Supply Installation and User Guide (11/09) 4.2 When Calling for Assistance ............................................................. 24 4.3 Return Material Authorization (RMA) Procedure ............................. 25 4.4 Shipping and Packaging Information................................................. 26 APPENDIX A: WARRANTY INFORMATION ......................................... 28 Revisions Rev. B 11/09: Rev. A 07/09: Updated DIN Rail mount photo (Sec. 3.1.
IPS42 Internal Power Supply 1.0 SPECIFICATIONS Installation and User Guide (11/09) 1.1 Technical Specifications AC/DC Power Supply (Model IPS42-AC/DC): Power Input: DC: 100-250 VDC AC: 100-250 VAC, 47 to 63 Hz, auto ranging Surge Rating: IEC 61000-4-3, Class 3/4 (4KV for DC) Std.
IPS42 Internal Power Supply Installation and User Guide (11/09) AC Power Supply (Model IPS42-AC) AC Power Connector: standard IEC 320 male, recessed Power Input: 100-250 VAC, 47 to 63 Hz, auto ranging Power Consumption: 10 Watts typical for a 4+2 port fiber model Mechanical Specifications: Enclosure: Rugged sheet metal (Aluminum). Dimensions of the IPS42 unit: 6.0 in H x 5.5 in W x 1.7 in D (15.2 cm x 14.0 cm x 4.3 cm) Weight: all models: 1.5 lbs. (0.
IPS42 Internal Power Supply Cooling Method: Installation and User Guide (11/09) All IPS42 models feature convection cooling for temperature un-controlled locations. All models have closed cases to withstand dirt and use special thermal techniques to transfer heat to the outside of the case for cooling. ALARM RELAY Terminal Block, four screw terminals: Internal 60VA relay contact: Open for power Off, closed for power On (Hardware).
IPS42 Internal Power Supply Installation and User Guide (11/09) Agency Approvals and Standards Compliance: UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A IEC 61850 EMC and Operating Conditions Class C Power Substations IEEE 1613 Env. Standard for Electrical Power Substations NEBS L3 and ETSI compliant including vibration, shock and altitude NEMA TS-2 and TEES for traffic control equipment Warranty: Three years, return to factory Made in USA www . GarrettCom .
IPS42 Internal Power Supply Installation and User Guide (11/09) 1.2 Summary of models and descriptions for IPS42 Series: IPS42-AC/DC: Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power supply) as a separate line item. Rated 100 to 250 VAC or VDC. Power input via recessed terminal block, UL Listed and Surge protected.
IPS42 Internal Power Supply Installation and User Guide (11/09) IPS42-48VDC-DualSRC: Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power supply) as a separate line item. Rated 44 to 57 VDC, Dual Source. Power input via recessed terminal block, UL Listed and Surge protected. IPS42-24VDC-DualSRC: Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch.
IPS42 Internal Power Supply Installation and User Guide (11/09) IPS42-AC: Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power supply) as a separate line item. Standard worldwide AC power input via standard IEC320 recessed male connector, UL Listed and Surge protected. IPS42-AC Accessories DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one IPS42 Series product (see Section 3.
IPS42 Internal Power Supply 2.0 INTRODUCTION Installation and User Guide (11/09) 2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
IPS42 Internal Power Supply Installation and User Guide (11/09) Remove the Magnum IPS42 Series Internal Power Supply from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or damaged contact your supplier. If you need to return the unit, use the original shipping container. Refer to Section 4 Troubleshooting, for specific return procedures. 2.
IPS42 Internal Power Supply Installation and User Guide (11/09) 2.3 Features and Benefits 100 to 250V range, 4KV surge protected AC/DC models are rated at 100-250V with a maximum of 4KV surge suppression. The only High Voltage AC/DC Ethernet unit on the market that is UL Listed for user safety. Dual-Source power input 125VDC, 48VDC and 24VDC models are equipped with Dual-Source inputs for high availability.
IPS42 Internal Power Supply 3.0 INSTALLATION Installation and User Guide (11/09) This section describes the installation of the Magnum IPS42 Internal Power Supply, including location, mounting, power cord and media connections. 3.1 Locating the IPS42 The compact and lightweight design of the Magnum IPS42 Series allows it to be easily installed in almost any location.
IPS42 Internal Power Supply Installation and User Guide (11/09) Installation of the Magnum IPS42 Series of products is a simple procedure. The installation location is dependent upon the physical layout of the Ethernet network and associated cabling. Make sure the unit is installed in a location that is easily accessible to an AC power outlet or the appropriate DC source and where cooling is not inhibited. The green Power (PWR) LED must turn ON when power is applied. 3.1.
IPS42 Internal Power Supply Installation and User Guide (11/09) Note: The metal brackets supplied hold the back of the IPS42 unit out from the panel or wall behind it, creating a rear space of about ¼ inch or 1cm. This allows air circulation and cooling of the rear part of the case. For best cooling of the IPS42 Series, attach the metal brackets to metal (rather than wood or plastic).
IPS42 Internal Power Supply Installation and User Guide (11/09) The unit is mounted using the brackets as shown in the illustration above. The spacing for the mounting screws into the supporting wall or panel is a rectangle 15.49 x 12.89 cm (6.10 x 5.075 inches) center-to-center. www . GarrettCom .
IPS42 Internal Power Supply Installation and User Guide (11/09) 3.1.2 DIN-Rail mounting option The Magnum IPS42 Power Supply, designed for use in “Factory Floor” Industrial Ethernet environments, is available for DIN-Rail mounting in an enclosure having DIN Rails. A Magnum IPS42 is shown with the DIN-RAIL-MC2 bracket installed The metal DIN-Rail mounting hardware is optional and needs to be ordered as a separate item, e.g. Model #DIN-RAIL-MC2.
IPS42 Internal Power Supply Installation and User Guide (11/09) 3.2 Power Cord Installation For IPS42-DC w/Dual Source and AC/DC models that do not have the power cord installed at the factory, follow the procedures as described below. For detailed technical specifications, refer to Section 1.1 of this User Guide.
IPS42 Internal Power Supply Installation and User Guide (11/09) Use the Power Cord installation kit (items for Dual Source shown in Fig. 3.2b) to connect the power cord to the unit. Note: For Single Source models, the kit will include a single opening power cord cover and one protective bushing. a. Slide the power cord cover (pictured in Fig. 3.2b) over the cordage to be used. Note: The 4-position terminal block accepts 28-16 AWG wire. b.
IPS42 Internal Power Supply Installation and User Guide (11/09) For Dual Source models, positions A and B will be used. For Single Source models, only position A will be used. NOTE: None of the conductor can be exposed after secured in the terminal block. c. Install the protective bushings and secure to the power cord cover. d. Secure the assembled terminal block to the mating piece of the unit. (see Fig. 3.2d) e. Secure the assembled power cord cover to the IPS42 case. (see Fig. 3.2e) f.
IPS42 Internal Power Supply Installation and User Guide (11/09) (+) W BRO N or CK (+ B LA ) BLUE or WHITE (-) GR N /YLW or G REE N (G ND) (-) (GND) www . GarrettCom .
IPS42 Internal Power Supply Installation and User Guide (11/09) 3.3 Hardware operated Alarm Contact The two screw Alarm Contacts feature, standard on Magnum IPS42-Series, provides Normally Closed (NC) contacts to which the user can attach one set of status monitoring wires at the green terminal block. The NC Alarm Contact is held close when there is power on the main board inside of the IPS42.
IPS42 Internal Power Supply Installation and User Guide (11/09) 1. Four-position terminal block (positions 1 & 2) as shown in Figure 4.4a 2. The Alarm Relay contact connected to the two terminals (1, 2) is hardware operated. 3. By default it is NC (normally closed). It will open if there is any loss of power to the electronics inside of the unit. 4.0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments.
IPS42 Internal Power Supply Installation and User Guide (11/09) 4.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual. Also check to make sure that the various components of the network are interoperable. 2. Check the cables and connectors to ensure that they have been properly connected and the cables/wires have not been crimped or in some way impaired during installation.
IPS42 Internal Power Supply Installation and User Guide (11/09) 4. Make sure that an AC power cord is properly attached to each Magnum IPS42 Series unit. Be certain that the AC power cord is plugged into a functioning and appropriate electrical outlet. Use the PWR LEDs to verify each unit is receiving power. 5. If the problem is isolated to a network device other than the Magnum IPS42 Series product, it is recommended that the problem device is replaced with a known good device.
IPS42 Internal Power Supply Installation and User Guide (11/09) 4.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations/Environment when the problem occurs; c. The components/devices involved in the problem; d. Any particular application that, when used, appears to create the problem; 2.
IPS42 Internal Power Supply Installation and User Guide (11/09) 4.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization (RMA) number. To obtain an RMA number, please use this URL https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form. Please have the following information readily available: Name and phone number of your contact person.
IPS42 Internal Power Supply Installation and User Guide (11/09) GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as: No Problem Found.
IPS42 Internal Power Supply Installation and User Guide (11/09) CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the unit. 2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container. 3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Attn.: Customer Service www . GarrettCom .
IPS42 Internal Power Supply Installation and User Guide (11/09) APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom.