Magnum P62-Series Corporate Headquarters (P62F and managed mP62 models) GarrettCom, Inc. 213 Hammond Avenue Fremont, CA 94539 Phone: 510.438.9071 Fax: 510-438-9072 Web: www.GarrettCom.com Hardened Ethernet Switches Email: support@Garrettcom.com Installation and User Guide www . GarrettCom . com www . GarrettCom .
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Magnum™ P62-Series (P62F and managed mP62 models) Hardened Ethernet Switches Installation and User Guide Part #: 84-00092, (Rev I 11/03) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum, Personal Switch, S-Ring Redundancy Manager (patent pending) and Link-Loss-Learn (patent pending) are trademarks and Pe
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Drive Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) MAGNUM ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" Overview GarrettCom, Inc. offers the Magnum line of Ethernet LAN connectivity products with industry-standard functionality. Magnum products are heavy duty, feature fiber-built-in ports, and have AC and DC power options to make them suitable for a variety of Industrial and Carrier Class applications.
Magnum P62-Series Hardened Switches TABLE OF CONTENTS Installation and User Guide (11/03) PAGE 1.0 SPECIFICATIONS..............................................................................................2 Technical Specifications ...................................................................................2 Ordering Information ........................................................................................5 2.0 INTRODUCTION ..............................................................
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Rev B 08/01: This revision includes the update of additional power source Rev A 04/01: This revision is the initial release of the P62F Hardened Switches user manual. 1.0 SPECIFICATIONS 1.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Operating Shock and Vibration: Meets Bellcore GR-63-CORE Conformal coating (tropical humidity protection) optional, request quote Power Supply (Internal) 24VDC and -48VDC Power Supply Power Input Voltage: 20 to 60 VDC (auto-ranging), “-, GND, +” Power Consumption: 10 watts typical. DC-DC Converter Rating: 5VDC, 2Amps Power Supply (Ext.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) is transmitting / receiving. F/H (RJ-45 ports only): ON = full-duplex, OFF = half-duplex MTBF (Bellcore method) Over 10 years MTBF. Email sales@GarrettCom.com for details Agency Approvals UL Listed (UL 60950), cUL, CE Emissions meet FCC part 15, Class A. NEBS L3 and ETSI compliant. IEEE P1613 Environmental Standard for Electric Power Substations.
Magnum P62-Series Hardened Switches 1.2 Installation and User Guide (11/03) Ordering Information Magnum P62-Series, 10/100 Ethernet Switch Magnum P62F-AC-2MSC: P62F-AC Ethernet Switch with six 10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Has 16KB address table and 1.0 MB packet buffers. AC power input, 85-160vac 47-63Hz worldwide auto-ranging via PSX-A power source Extended Temp ( a separate unit).
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Magnum Model P62F-5V Switch. Magnum PSX-T: Same as PSX-A , except 125VDC to 250VDC input, terminal lugs for “+”, “-“, and GND Managed P62-Series (mP62) Hardened Switches Magnum mP62-AC-2MSC: mP62-AC Managed Switch with six10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Software includes menu-driven user interface for ease of use, SNMP, QoS, Telnet, Security, STP, VLAN, BootP/DHCP.
Magnum P62-Series Hardened Switches 2.0 INTRODUCTION 2.1 Inspecting the Package and Product Installation and User Guide (11/03) Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Magnum P62-Series Hardened Switches 2.2 Installation and User Guide (11/03) Product Description The Magnum P62-Series Ethernet “Outdoor” Switches are designed to operate in extended temperature applications and are suitable for use in environments with inhospitable high / low temperatures. Magnum P62-Series Hardened switches provide two built-in 100Mb fullduplex switched fiber ports so that several units can be daisy-chained.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) performance plug-and-play operation in a rugged package. The high-strength steel enclosure gives extra protection. Each P62-Series Hardened Switch is non-blocking on all ports and has large packet buffers and a 4K-node address table for advanced performance. A Magnum P62-Series Switch, with store-and-forward switching ability, filters all faulty packets to minimize traffic congestion. 2.2.1 Magnum P62-Series chassis w/fiber SC (m.m.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) The Magnum P62-5V models are available with an External Power Source (Optional) for power input of universal AC power using the Magnum PSX-A unit. The 125/250 VDC model (PSX-T) input power supports a range of 100-275VDC and comes with input safety shield, fuses, and is diode-protected against accidental reverse polarity connection.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) The serial (Console) port is provided on the right front of the Managed mP62 Switch to use the Console Management Interface(CMI) to manage all functions of the switch. In addition, the Link-Loss-Learn™ feature (patent pending) in mP62’s allows rapid operating recovery from a link loss.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) format, a separate document normally accessed via the web-browser, ftp://ftp.garrettcom.com/ or FTP client program by ftp.GarrettCom.com using user : mpuser password : mpuser All the MNS-mP Software related information and NEW releases related to MNS-mP Software and Hardware for mP62’s can be accessed and download from Garrettcom’s FTP site. Or please visit www.GarrettCom.com/techsupport/index.
Magnum P62-Series Hardened Switches 2.2.5 Installation and User Guide (11/03) RS-232 (DB-9) Console Com. port pin assignments. Pin 1 Pin 5 DB-9 (Console port connector) Pin Signal Description 1 CD Carrier detect (not used) 2 RXD Receive Data (input) 3 TXD Transmit Data (output) 4 open not used 5 GND Signal Ground 6-9 open not used The above provided information enables a managed station( a PC or Console terminal) to connect directly to the switch using a straight through cable.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) On Magnum P62-Series units, there are three LED’s for each of the RJ-45 switched ports. The F/H indicates full-duplex when ON or half-duplex when OFF. The (LK/ACT) LED is steady ON to indicate LINK, and blinking to indicate transmitting / receiving. The 10/100 LED is ON for 100Mbps and OFF for 10 Mbps (when LINK is made). For fiber ports, the LEDs are the same except there is no F/H LED because 10Mb is not possible.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) across the ports. Since the traffic on an operating network is constantly varying in packet density per port and in aggregate density, the Magnum P62-Series Hardened Switches are constantly adapting internally to provide maximum network performance with the least dropped packets.
Magnum P62-Series Hardened Switches 2.5 Installation and User Guide (11/03) Features and Benefits 100Mb switching services for high performance Ethernet LANs Magnum P62-Series Switches provide Fast Ethernet switching on all ports. They perform high speed filter/forward operations on the traffic, giving each port’s segment a full 100Mb (or possibly 10 Mb for RJ-45 ports) of bandwidth.
Magnum P62-Series Hardened Switches 2.6 Installation and User Guide (11/03) Applications The P62-Series is designed specifically for harsh temperature environments and brings future-proof fiber and widely-used copper connectivity to out-of-the-way sites. Example 1. Magnum P62F In this example, a Magnum P62F Hardened Switch performs roadside real time traffic data collection and transmits it to a remote control station over fiber.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Example 2. The Magnum P62F fits very well in high temperature locations (control rooms) experiencing a need to scale its LAN quickly and cost effectively. With its half / full duplex switching capability, the P62F provides a very economical high bandwidth solution at each copper-cable user-access point. The 10/100 dual-speed functions to support a mixed environment of 10 Mbps and 100Mbps users and devices.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Example 3. Magnum mP62 PWR Magnum QS511 6K25 QS5116 10/100 6 Managed Fiber Fiber Switch Switch GARRET 1 F/ ACT F/ 2 TX LK RX 3 5 1 7 LK ACT ACT F/H 6 TX LK R 3 5 7 1 LK 10/100 F/ ACT F/ 2 TX LK RX ACT ACT F/H 6 TX LK R 3 5 7 LK 10/100 F/ ACT F/ 2 TX LK RX ACT ACT F/ TX LK R Magnum mP62 TT Magnum mP62 TT Magnum mP62 Magnum mP62 TT TT Magnum mP62 TT Magnum mP62 TT Fig .2.6.
Magnum P62-Series Hardened Switches 3.0 Installation and User Guide (11/03) INSTALLATION This chapter provides instructions for installing Magnum P62-Series units. 3.1 Locating Magnum P62F-Series 10/100Mb Ethernet Switches The location of a Magnum P62-Series Hardened Switch is dependent upon the physical layout of the network. The rugged 18-gauge sheet steel case that acts as a heat sink will normally protect the P62-Series from accidental damage in any application setting.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) 20.1cm) center-to-center. Four user-supplied screws, ¼” max diameter, attach the P62’S base plate to the vertical mounting surface. The PSX Power Source mounting is similar. The mechanical drawings in Figures 1 & 2 below provide the mounting holes measurement information for the PSX unit (mounted on top, if present) and for the Magnum P62-Series unit. 1.44" (3.7) 3.35" (8.5) Fig. 1 INPUT FUSE 250VDC, 0.5A (3AG) 6.18" (15.
Magnum P62-Series Hardened Switches 3.2 Installation and User Guide (11/03) Connecting Ethernet Media, and Special Strain-relief feature Note – see also “Cable Strain Relief Feature, Section 3.4. The Magnum P62-Series Ethernet Switches (P62F model illustrated here) can be connected to the following three media types: 100BASE-TX, 10BASE-T and 100BASE-FX. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used.
Magnum P62-Series Hardened Switches 1. 2. 3. 4. Installation and User Guide (11/03) Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used. Connect the other end of the cable to the corresponding device.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) longer distances, about 20Km with the single-mode SC. The same procedures as for multi-mode fiber apply to single-mode fiber connectors. Follow the steps listed in Section 3.2.2 above. 3.2.5 Power Budget Calculations for P62-Series Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget.
Magnum P62-Series Hardened Switches 3.2.6 Installation and User Guide (11/03) Connections to NICs which support Auto-Negotiation, RJ-45 ports The copper ports of Magnum P62-Series Hardened Switches will function properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system.
Magnum P62-Series Hardened Switches a) Installation and User Guide (11/03) UL Requirements The following must be adhered to in order to conform to UL requirements: 1. Minimum 18 AWG cable for connection to a Centralized DC power source. 2. Minimum 14 AWG cable for connection to earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent. 5.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Operating Shock and Vibration: meets Bellcore GR-63-CORE Sections 4.4.1 and 4.4.3 NOTE : For best results at high-temperature, fasten the metal case of the PSX-A unit to be in contact with a vertical surface (such as pedestal) that has good heat conducting properties. Remove rubber “feet”, if present, to enhance metal-to-metal contact and provide the best heat transfer away from the PSX-A unit. 3.3.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) to be in contact with a vertical surface (such as pedestal) that has good heat conducting properties. Remove rubber “feet”, if present, to enhance metal-to-metal contact and provide the best heat transfer away from the PSX unit. UL Requirements The following must be adhered to in order to conform to UL requirements: 6. Minimum 18 AWG cable for connection to a Centralized DC power source. 7.
Magnum P62-Series Hardened Switches 3.5 Installation and User Guide (11/03) DIN-Rail mounting option for mP62 Series The Magnum P62-Series Ethernet “Outdoor” Switches are designed to operate in extended temperature applications and are suitable for use in environments with inhospitable high / low temperatures. In order to mount the P62-Series, in DIN-RAIL track panel, it is also available with DIN-Rail mounting option, which is provided at the bottom side of the unit, as shown in the picture below.
Magnum P62-Series Hardened Switches 4.0 Installation and User Guide (11/03) OPERATION This section describes the function and operation of the Magnum P62-Series Switches. 4.1 Dual-Speed Functionality, and Switching The Magnum P62-Series Hardened Switch provide six 10/100 RJ-45 switched ports, and two 100Mb fiber ports. The architecture supports a dual speed switching environment, with two built-in full-duplex “future-proof” fiber ports.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) An address-aging algorithm causes least-used addresses to fall out in favor of new frequently-used addresses. To reset the address buffer, cycle power down-and-up. 4.2 Auto-negotiation and Speed-sensing All six RJ-45 ports independently support auto-negotiation for speed in 10BASE-T and 100BASE-TX modes. Operation is according to the IEEE 802.3u standard.
Magnum P62-Series Hardened Switches 5.0 Installation and User Guide (11/03) TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation Magnum P62-Series Hardened Switch is a straightforward procedure (see INSTALLATION, Section 3); the operation is also straightforward and is discussed in Section 4.
Magnum P62-Series Hardened Switches 5.2 Installation and User Guide (11/03) When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations when the problem occurs; c. The components involved in the problem; d. Any particular application that, when used, appears to create the problem; 2.
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as: No Problem Found.