Corporate Headquarters GarrettCom, Inc. Magnum P80F & P80C Personal Switches 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Installation and User Guide www . GarrettCom . com www . GarrettCom .
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) Magnum™ P80F & P80C Personal Switches Installation and User Guide Part #: 84-00079, (Rev B 4/01) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Switch is a registered trademark of GarrettCom, Inc.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary consideration.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) TABLE OF CONTENTS PAGE 1.0 SPECIFICATIONS ........................................................................................2 1.1 Technical Specifications..................................................................................... 2 1.2 Ordering Information.......................................................................................... 4 2.0 INTRODUCTION.....................................................
Magnum P80F & P80C Personal Switches 1.0 SPECIFICATIONS 1.1 Technical Specifications Installation and User Guide (07/03) Ports Performance When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) External -48VDC Power Supply (Optional) Power Input Voltage: 36 to 70 VDC (auto ranging), “-, GND, +” Power Consumption: 8 watts typical, 10 watts max. Network Cable Connectors - for eight RJ-45 shielded female ports and 1 fiber port 100Mbps: Category 5 UTP/STP, fiber (50/125, 62.
Magnum P80F & P80C Personal Switches 1.2 Installation and User Guide (07/03) Ordering Information Magnum P80F, 10/100 Personal Switch with a 100Mb Fiber Port Magnum P80F-MSC-d, or -i: 8-port Personal Switch with one 100Mbps switched fiber port (multi-mode SC-type connector), and seven “N-way” half- or full-duplex switched RJ-45 10/100 auto-negotiating ports. Includes store-and-forward switching that filters and forwards data moving between the ports.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 2.0 INTRODUCTION 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) negotiating ports. For half- or full duplex selection on the P80F, and Full-fixed and Autonegotiation selection on the P80, see sections 4.3 and 4.4. The Magnum P80 & P80F Personal Switches provide the switching speed and the reliability to smoothly support multiple workgroups at 100Mbps or 10 Mbps speed.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) port. Port # 2SW always supports fiber ports only and the RJ-45 connector is inoperative at all times. LEDs to indicate operating status of all ports are mounted on the top. There are power (PWR) and ERROR (self-test at power up failed) indicators for the unit. For each port, there are Link and Activity (LINK/ACT) LEDs indicating traffic, and speed (ON for 100Mbps), and full/half (F/H) duplex indicators.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) When the up-link port is used to cascade two P80-series Personal Switches, the auto-sensing feature will cause the connecting link to operate at 100Mbps speed and full-duplex mode. 2.
Magnum P80F & P80C Personal Switches 2.5 Installation and User Guide (07/03) Frame Buffering and Latency The Magnum P80 & P80F are store-and-forward switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding can occur. This technique ensures that all forwarded frames are of a valid length and have the correct CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all of the available bandwidth to be used for valid information.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) processing resumes. This flow-control sequence occurs in a small fraction of a second and is transparent to an observer. See Section 4.6 for additional details. Another feature implemented in Magnum P80 & P80F Personal Switches is a collision-based flow-control mechanism (when operating at half-duplex only).
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) Up-Link on port # 1 for a high speed “copper” connection An up-link switch is built in for port # 1. The F/H 10/100 switched RJ-45 port # 1 can support a local server, a power user, another hub or switch cascaded, or a switched “stack” connection to another P80F or P80C for expansion.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 5V, 2Amps Magnum P80 Personal Switch Link/Act Speed F/H Power Error GARRET PORTS Tx Rx 1 UPLINK UPLINK = F 100Mbps fiber 1SW 2 2 3 4 3 5 4 6 5 7 6 8 7 8 X H 2SW Print Server 1 2 3 4 100 5 6 1 2 3 4 5 6 100 Server 100 100 100 10 10 Mbps 10 Mbps Figure 2.7.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 5VDC, Magnum P80 Personal Link/Act Speed F/ Powe Erro GARRET Tx Rx PORTS 1 UPLINK UPLINK 2 3 3 1SW 4 5 4 6 5 7 6 7 = FF A 2SW 12V, 1.5Amps Magnum DS80C Dual Personal Hub Powe Erro Link/Ac Spee PORTS 1SW F/ GARRETT Tx Rx UPLINK UPLINK = F X 2SW 3 2 4 3 1S 1 H 3 4 5 6 4 5 5 7 6 8 7 8 6 Print Server 2S Router 10 Serve 10 10 1 10 1 Users 100Mb Servers and Workstations Figure 2.7.
Magnum P80F & P80C Personal Switches 3.0 Installation and User Guide (07/03) INSTALLATION This chapter provides instructions for installing Magnum P80-series units. 3.1 Locating Magnum P80F & P80C 10/00Mb Personal Switch The location of a Magnum P80F & P80C Personal Switch is dependent on the physical layout of the network. Typically the switch is located in a workplace site.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) metal screws for each bracket and attaching to the Magnum P80F and P80C through the round hole of the bracket. A user-supplied screw attaches the bracket to the mounting surface. It is recommended to use appropriate # 4 screws for attaching mounting bracket to wall (e.g wood screw, self-tapping screw, machine screw). It is also recommended that the brackets be attached to two opposite corners of the unit.
Magnum P80F & P80C Personal Switches 1. 2. 3. 4. Installation and User Guide (07/03) Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used. Connect the other end of the cable to the corresponding device.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) The same procedures as for multi-mode fiber apply to single-mode fiber connectors. Follow the steps listed in Section 3.2.2 above. 3.2.5 Power Budget Calculations for P80F Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) (FLP) coding for the 100BASE-TX signaling system. When connecting a NIC to the P80F or P80C, it may be necessary to reload the NIC drivers on the user device if the NIC has been communicating with a protocol other than 100BASE-TX (such as 10BASE-T). When 100Mb operation is agreed and in use, the SPEED LED is illuminated steady ON. It is OFF if there is no traffic or if 10 Mbps traffic. 3.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 4.0 OPERATION - the function and operation of the Magnum P80F and P80C switches. 4.1 Dual-Speed Functionality, and Switching The Magnum P80F and P80C Personal Switches provide eight switched ports, one of which may be 100Mb fiber on Model P80F. The architecture supports a dual speed switching environment, with a built-in full-duplex “future-proof” fiber port on the Model P80F.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) removed or moved from one segment to another, the P80F and P80C automatically keeps up with node locations. An address-aging algorithm causes least-used addresses to fall out in favor of new frequently-used addresses. To reset the address buffer, cycle power down-and-up. 4.2 Auto-negotiation and Speed-sensing All eight RJ-45 ports independently support auto-negotiation for speed in 10BASE-T and 100BASE-TX modes.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 4.5 LED’s PWR: Illuminates GREEN, steady on when power applied. ERROR: Indicates the self-test at power up was not successful SPEED: Per port, ON = 100Mbps; OFF = 10 Mbps (when LINK is made) LINK/ACT: Per port, steady ON for LINK with no traffic, blinking indicates port is transmitting and receiving. F/H: ON = Full-Duplex and Link, OFF = Half-Duplex and / or no Link. 4.
Magnum P80F & P80C Personal Switches 5.0 Installation and User Guide (07/03) TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation of Magnum P80F & P80C Personal Switch is a straightforward procedure (see INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in Section 4.
Magnum P80F & P80C Personal Switches 5.2 Installation and User Guide (07/03) When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations when the problem occurs; c. The components involved in the problem; d. Any particular application that, when used, appears to create the problem; 2.
Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) No Problem Found. GarrettCom reserves the right to charge for the testing of non-defective units under warranty. Testing and repair of product that is not under warranty will result in a customer (user) charge. 5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available.