User manual

Magnum 6KQE Managed Edge Switch Installation and User Guide 02/09
24
www GarrettCom com
..
3.6 Connecting the Console Terminal to Magnum 6KQE
Use a (DB-9) “null modem” cable to connect the Magnum 6KQE Console Port
(the RS-232 port on the 6KQE Switch) to your PC, so that your PC becomes
the 6KQE Console Terminal.
Note: The DB-9 cable is not included with the 6KQE package.
Note: For a detailed description of Managed Network Software (MNS-6K) and
Magnum 6KQE Switch configuration for Network Management, please refer to
Magnum 6K Software Manual available on GarrettCom‘s FTP site.
Also available on GCI website at:
http://www.garrettcom.com/techsupport/sw_downloads.htm
3.6.1 RS-232 (DB-9) Console port (Serial port) pin assignments
DB-9 (Console port connector)
Pin Signal Description
1 DCD Data Carrier detect (not used)
2 RXD Receive Data (input)
3 TXD Transmit Data (output)
4 open not used
5 GND Signal Ground
6 open not used
7 RTS Request to Send
8 CTS Clear to Send
9 open not used
The above provided information enables a managed station (a PC or Console terminal) to
connect directly to the switch using a straight through cable.
Note
: To use the Console port to configure the managed switch, a serial (Null-modem)
female to female cable is required to communicate properly. The Null-Modem (DB-9)
cable is optional and can be ordered from the factory, along with the unit as-
CONSOLE CBL for serial port
CONSOLE USB for USB port