Corporate Headquarters Magnum CSG14 Gigabit Converter Switches GarrettCom, Inc. CSG14U 47823 Westinghouse Drive Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support@garrettcom.com CSG14 Installation and User Guide www . GarrettCom . com www . GarrettCom .
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Magnum CSG14 Series Gigabit Converter Switch Installation and User Guide TM Part #: 84-00102Z Rev. F Trademarks GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch are trademarks of GarrettCom, Inc.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Important: The Magnum CSG14 Series 10/100/1000 Mb/s Converter Switches contain no user serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. If problems are experienced with Magnum CSG14 10/100/1000 Mb/s Converter Switch products, consult Section 5, Troubleshooting, of this User Guide. Copyright © 2008 GarrettCom, Inc. All rights reserved.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Electrical Safety requirements: 1. This product is to be installed Only in Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets, or the like). 2. 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product. 3.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Drive Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support@garrettcom.com www . GarrettCom .
CSG14 Series Gigabit Converter Switch TABLE OF CONTENTS Installation and User Guide (12/08) Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications ...................................................................... 1 1.2 Summary of models and descriptions: ............................................... 11 2.0 INTRODUCTION ............................................................................... 16 2.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Converters .......................................................................................... 47 3.4 DIN-Rail mounting option ................................................................. 49 3.5 Power Requirements for CSG14 Series Switches .............................. 50 3.6 Powering the CSG14 with 12V, 24V or –48VDC power input ......... 51 3.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing................ 64 4.3 Dual LEDs, Top-front and in End with ports .................................... 65 5.0 TROUBLESHOOTING ...................................................................... 66 5.1 Before Calling for Assistance ............................................................ 67 5.2 When Calling for Assistance ..................................................
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 1.0 SPECIFICATIONS 1.1 Technical Specifications Ports Performance Data Rate: 10Mbps, 100Mbps, 1000Mbps Network Standards 1000Mb: Ethernet IEEE 802.3ab and 802.3z 1000Base-T, -SX, -LX and -ZX 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3z Packet-Processing Between Domains Filter and Forward Rate from 1000Mbps ports: 1,488,000 pps max.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Packet buffers memory: 64KB, dynamically shared on all domains Latency (not including packet time): 100 to 10 Mbps: 5μs 10 to 100Mbps: 15μs Path Delay Value: 50 BT on all ports Maximum Ethernet Segment (or Domain) Lengths 10BASE-T (Unshielded twisted pair) 10BASE-FL, Fiber optic 10BASE-FL, Single-mode Fiber optic 100BASE-TX (CAT 5 UTP) 100BASE-FX, half-duplex: (multi-mode) 100BASE-FX, full duplex: (multi-mode) 100BASE-FX, half-duple
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 1000BASE-ZX, full duplex, single-mode (9um) >70 km (229,659 ft) Operating Environment CSG14H / CSG14UH: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL) -40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests CSG14P / CSG14UP: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL) -40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests Storage Temperature, All models: -40ºF to 212ºF (-40ºC to 100ºC)
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Note: CSG14 models are designed for NEBS compliance, including, vibration, shock and altitude. Packaging: Enclosure: Rugged sheet metal (Aluminum) Dimensions of the Switch unit: 3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm) Weight: CSG14H / CSG14P: 9 oz. (255g) CSG14UH / CSG14UP: 6.1 oz. (173g) Power supply, –Hd, and Hi: 5.8 oz (165g) –Pd, and -Pi: 7.9 oz (225g) Cooling Method: Convection on the CSG14 Series models.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) POWER SUPPLY AC POWER SUPPLY (using an external power adapter): All models have a (8-15) VDC output with 6ft long cord and a 2.5mm center +ve jack. The power supplies are temperature rated to match the Converter Switch ratings. Factory Floor (H) Ratings (-25 to 60°C) North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Temperature un-controlled Premium (P) Ratings (-40 to 75°C) North America (-Pd) models. Outdoor temperature rated. Input: 6ft AC power cord to IEC 320 connector on the100240vac 47-63Hz external power adapters. Output: 12vdc, 2Amps. International (-Pi) models. Outdoor temperature rated. Input: IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord. Output: 12vdc, 2Amps.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Power Consumption: See Section 3.6. Note 1: the 8-15V DC jack can be used for dual source DC input using an AC adapter and the DC terminal block. Power supply protection is provided by internal diodes. Note 2: The Direct DC power floats. The user may ground either “+” or “-” if desired. Port Connectors (CSG14H / CSG14P: Two RJ-45 Ports: supports 10/100/1000Mbps with auto cross (MDIX).
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Switches (CSG14H / CSG14P) Fiber port default is FDX (Full-Duplex) RJ45’s are triple-speed auto-negotiating Switches (CSG14UH / CSG14UP) Each SFP port is factory set to Gb speed User may select 100Mb speed via DIP switch on the back of the unit Each SFP port is individually speed-selectable NOTE: After changing the speed switch setting, power cycle the unit for the speed setting to take effect. www . GarrettCom .
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) PO RT 1 Gb LK/ACT POWER PORT 2 PORT 3 LED Indicators (Two sets) top-front and end with ports Top-Front: (shown) POWER: Steady ON when power applied Gb per port: Steady ON for 1000Mbps; OFF for 100Mbps or 10Mb speed LK/ACT per port: Steady ON for LINK (LK) with no traffic, BLINKING for Activity End with Ports: POWER: Steady ON when power applied 10/100/Gb per RJ45 port: Steady ON for 100Mb, OFF for 10Mb, BLINKING for Gb Fiber port
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Mounting options Metal mounting clips for panel mounting: included DIN-Rail mounting option: Model # DIN-RAIL MC2 (see Section 3.4) Rack-mount option: MC14-TRAY, see http://www.garrettcom.com/mc_tray.htm Mean Time Between Failure (MTBF) – over15 years, Telcordia (Bellcore) Method Agency Approvals and Standards Compliance: UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A. NEBS L3 and ETSI compliant.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 1.2 Summary of models and descriptions: CSG14H (Hardened Model) for 1000Mb fiber CSG14H-ff-Hd, Hi = CSG14H-ff-12VDC = CSG14H-ff-24VDC = CSG14HR-ff-24VDC = CSG14H-ff-48VDC = Hardened (H), two 10/100/1000Mb RJ-45+ one 1000Mb Fiber port for factory floor (-25 to 60C) using a direct DC ( 8-15VDC) and/or external AC hardened power supply (included).
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) CSG14P (Premium Model) for 1000Mb fiber CSG14P-ff-Pd, Pi = CSG14P-ff-12VDC = CSG14P-ff-24VDC = CSG14PR-ff-24VDC = CSG14P-ff-48VDC = Premium (P), two 10/100/1000Mb RJ-45+ one 1000Mb Fiber port for uncontrolled(outdoor) (-40 to 75C) using direct DC (8-15VDC) and/or external AC premium power supply (included). Same as CSG14P-Pd, Pi, except AC Premium Power Supply is not included.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) “LX25” = 1000Base-LX-SLC: 1310nm single-mode fiber optic with LC type connector, 25 km “ZX40” = 1000Base-ZX-SLC: 1550nm single-mode fiber optic with LC type connector, 40 km “ZX70”= 1000Base-ZX-SLC: 1550nm single-mode fiber optic with LC type connector, 70 km “SFP” = open SFP transceiver slot in the fiber position.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) except 24VDC power input replaces 12VDC. CSG14UHR-ff-24VDC = Same as CSG14UH-24VDC model, but includes DIN-RAIL-MC2 mounting option.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Fiber Port Connectors (CSG14UH / CSG14UP): The “ff” field is for selection of the desired “fiber flavor” as listed below. “SFP” = open SFP transceiver slot in the fiber position.
CSG14 Series Gigabit Converter Switch 2.0 Installation and User Guide (12/08) INTRODUCTION This section describes CSG14 Series models, including appearance, features and typical applications. 2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage, which you believe occurred during shipment or delivery.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Remove the Magnum CSG14 Series Converter Switch from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or damaged contact your supplier. If you need to return the unit, use the original shipping container. Refer to Section 5 Troubleshooting, for specific return procedures. 2.2 Product Description 2.2.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) (factory floor), and Premium-rated (outdoor) versions. Extra features for heavy-duty and extended temperature operation ranges are included selectively in the Hardened factoryfloor and Premium-rated outdoor models. This selection of models and fiber port types offers the best price-to-value ratio for each user and installation. Where a Media Converter might have been used, a Converter Switch offers a better value.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) The Magnum CSG14P Premium-rated units are for temperature un-controlled applications (-40 to 75C), typically located outdoors. The CSG14P models are built with premium-grade extended temperature components, and use similar thermal techniques as the CSG14H Hardened units. In addition to a Premium-rated AC power option and jack, terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Fig 2.2.1a CSG14H with 1000Mb SC connector Fig 2.2b The ORANGE labeled Magnum CSG14H hardened units (as shown in Fig 2.2.1a) are designed for office and wiring closet environments and factory floor/Industrial applications. Using special thermal techniques and a sealed rugged metal case for heavy-duty industrial applications no air inflow is required for cooling, so the CSG14H resist dust, dirt, moisture, smoke and insects.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Fig 2.2.1b CSG14P with 1000Mb LC connector The RED labeled Magnum CSG14P Series (as shown in Fig. 2.2.1b) are premium rated units suitable for temperature uncontrolled outdoor applications. Specially designed with premium-grade extended temperature components, the CSG14P units use similar thermal techniques to the CSG14H hardened units for cooling. Mounting options include panel mounting, DIN-rail, or rack-mount tray.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) The front side of the unit has two twisted-pair 10/100/1000Mb switch ports and one 10, 100 or 1000Mb fiber port. Both the RJ-45 ports of the CSG14 Series Converter switches support auto cross (MDIX) operation performing the autocross function under auto-negotiation mode only. The CSG14 models are factory configured at Full Duplex.
CSG14 Series Gigabit Converter Switch 2.2.2 Installation and User Guide (12/08) CSG14UH / CSG14UP Product Description The latest technology of SFP fiber transceivers has been integrated into the Magnum Gb Converter Switch package to produce the Magnum CSG14U Universal Converter Switch. It can handle any Gb fiber type – multi-mode and single-mode – and fiber media distance with a selection of Gb SFP fiber transceivers, up to two of which can be plugged in.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Converter might have been used, a Converter Switch offers a better value. The compact package is ideal for network edge installations, and is able to be conveniently mounted to suit any application. The Magnum CSG14UH Hardened units are for the office and factory floor applications.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included. When used outdoors, the CSG14UP should be protected from falling rain. Mounting options include stand-alone panel mounting, DIN-rail, or rack-mount tray. The CSG14U series provides switching between one 10/100/1000 autonegotiating copper port and two 100 or 1000Mb fiber ports which are SFP multi-mode or single-mode.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Fig 2.2.2a CSG14UH with two SFP slots Fig 2.2b The ORANGE labeled Magnum CSG14UH hardened units (as shown in Fig 2.2.2a) are designed for office and wiring closet environments and factory floor/Industrial applications. Using special thermal techniques and a sealed rugged metal case for heavy-duty industrial applications no air inflow is required for cooling, so the CSG14UH resist dust, dirt, moisture, smoke and insects.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Fig 2.2.2b CSG14UP with two SFP slots The RED labeled Magnum CSG14UP Series (as shown in Fig. 2.2.2b) are premium rated units suitable for temperature uncontrolled outdoor applications. Specially designed with premiumgrade extended temperature components, the CSG14UP units use similar thermal techniques to the CSG14UH hardened units for cooling. Mounting options include panel mounting, DIN-rail, or rack-mount tray.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) The front side of the unit has one twisted-pair 10/100/1000Mb switch port and two 100 or 1000Mb fiber ports. The RJ-45 port of the CSG14U Series Converter switches support auto cross (MDIX) operation performing the autocross function under autonegotiation mode only. The CSG14U models are factory configured at Full Duplex.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 2.3 Frame Buffering and Latency The Magnum CSG14 Series Converter Switches are store-and-forward switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding can occur. This technique ensures that all forwarded frames are of a valid length and have the correct CRC, i.e. they are good packets.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Magnum CSG14 Series Converter Switch dynamically allocates buffer space from 64Kb memory pool, ensuring that heavily used ports receive very large buffer space for packet storage. (Many other switches have their packet buffer storage space divided evenly across all ports, resulting in a small, fixed number of packets to be stored per port. When the port buffer fills up, dropped packets result.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Another feature implemented in Magnum CSG14 Series Converter Switches is a collision-based flow-control mechanism (when operating at half-duplex only). When the Switch detects that its free buffer queue space is low, the Switch prevents more frames from entering by forcing a collision signal on all receiving half-duplex ports in order to stop incoming traffic.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 2.4 Features and Benefits Full 1000Mb, 100Mb or 10 Mb switching services for high performance Ethernet LANs Magnum CSG14 Series Switches provide Fast Ethernet switching on all ports. They perform high-speed filter/forward operations on the traffic, giving each port’s segment a full 1000Mb, 100Mb or 10 Mb of bandwidth.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) and the other RJ-45 port can be used as diagnostic port or for more connectivity. Installation is “Plug and Play”, operation is transparent to software The Magnum CSG14 Series Switches operate as hardware switches, only forwarding those packets from each domain that are needed on the other domains.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Qualified to use for temperature un-controlled “outdoor” application The Magnum CSG14P Premium rated versions of Converter Switches have an ambient temperature rating between –40C to +75C for DC models and qualify for temperature un-controlled “outdoor” application.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 2.5 Applications for CSG14 Series Converter Switches Enriched with the two tier “O-R” hardness rating flavors (Orange –“Hardened”, Red- “Premium rated (outdoor)”), the multifunctional, multi-media and multienvironmental, Magnum CSG14 Series Converter Switches fit very well in almost any environment enabling users to scale their networks quickly and cost effectively.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) provide a very economical high bandwidth solution at each cable user access point of copper, and also easily solve long distance requirements. The ruggedness of the CSG14P’s aluminum case and the high reliability of the design compliment the temperature-controlled packaging to provide an exceptional Ethernet product. www . GarrettCom .
CSG14 Series Gigabit Converter Switch Example 1: Indoor Office CSG14H www . GarrettCom .
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Example 1: In this example, the indoor office location is a Data Mining function with an ongoing demand to grow the network. This need can be easily met using the economical Magnum CSG14 Converter Switch. Additional functionality includes the ability to transfer data across large distances with multi- or single–mode fiber while securing the LAN from EMI and wire-tapping. www . GarrettCom .
CSG14 Series Gigabit Converter Switch Example 2: CSG14H www . GarrettCom .
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Example 2: In this application, where in expanding an industrial network environment, the new PLC units are deployed on an existing network and each needs one (or two for redundancy) Ethernet ports to carry status and control data to the control center the hardened version of Magnum CSG14H is typically used. .
CSG14 Series Gigabit Converter Switch Example 3: CSG14P www . GarrettCom .
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Example 3: In this example, the Magnum CSG14P Premium Converter Switches are deployed to serve as a secure corporate or transportation surveillance system. CCTV cameras may be spread out over many miles in temperature un-controlled locations and with pan, tilt and zoom (PTZ) controlled through an Ethernet copper port .
CSG14 Series Gigabit Converter Switch Example 4: CSG14U “Drop & Add” capability In this example, Magnum CSG14U Converter Switches form a gigabit backbone LAN with a “Drop & Add” capability that enables connecting many disparate devices in a fiber-media string, covering even very long distances (for example, a pipeline). Such designs are easily extended or expanded as conditions and devices needing network attachment change over time. www . GarrettCom .
CSG14 Series Gigabit Converter Switch 3.0 Installation and User Guide (12/08) INSTALLATION This section describes the installation of the Magnum CSG14 Series Converter Switches, including location; mountings and power supply options and media connection. 3.1 Locating the Converter Switch Unit All the CSG14 Series Switches operate in transparent half-and fullduplex mode.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) The compact and lightweight design of the Magnum CSG14 Series allows it to be easily installed in almost any location. A Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or shelf. Alternatively, metal mounting clips and screws are included for a rugged and secure mounting in any orientation.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 3.2 MC14-TRAY for Rack Mounting of CSG14 Series Switches For 19” rack-mounting of Magnum CSG14 Series Converter Switches, a rackmount tray is available, the MC14-TRAY. The Converter Switches are mounted with the DC power jack in the back, with the fiber and the RJ-45 connectors in the front. Any mix of the Converter Switches and/or Media Converters may be placed on a tray, up to a maximum of 16 units.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) with their power supplies plugged into power strips (not included) in the rear area of the tray. Metal mounting screws in the bottom-front hold the Converter Switches firmly in place. The beveled-top edge of the units permits the LEDs of each unit to be viewed for operational status, even when the units are very close together. 3.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 55 watts at 50°C ambient, 9 VDC regulated output, and supporting up to 10 Switches for MC14-TR+PS9 and 16 units CSG14 Series for MC14-TR+PS9X2. The MC14-TR+PS9X2 Model has two groups of eight units per power supply. The power supplies have autoranging AC input for use worldwide.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 3.4 DIN-Rail mounting option The Magnum CSG14HR and CSG14PR Converter Switches, designed for use in “Factory Floor” Industrial Ethernet environments, are also available for DIN-Rail mounting in an enclosure having DIN Rails. A Magnum CSG14H is shown alongside the DIN-Rail-MC2 bracket The metal DIN-Rail mounting hardware is optional and needs to be ordered as a separate item, e.g. Model #DIN-RAIL-MC2.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 3.5 Power Requirements for CSG14 Series Switches Magnum CSG14 Series Switches are power-efficient and can work with an external AC power supply. Magnum CSG14 Series require a 12VDC input power supply. The extended temperature (H and P) versions are used for heavy-duty industrial applications. The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in terminal block for +, -, ground. The 9V DC jack is also present. Detailed information about the 12 VDC, the 24V DC and the –48V DC is provided in the Technical Specifications Section 1.1. Various models of DC power type and extended ambient temperature power supplies are available. Specify the power supply needed on your order.
CSG14 Series Gigabit Converter Switch The extended temperature capability of the DC-powered CSG14P’s can go into temperature uncontrolled environments, rated at –40`C to +75`C. If indoors, the DC jack is also present and optionally can be used with an external AC power supply. DC Power Terminals: “+”, “-”, gnd GND: Terminal for “earth” or ground wire connection to the CSG14H chassis Input Voltage: 8 - 15V DC (12V DC) 18 – 36V DC (24V DC) 36 – 60V DC (-48V DC) www . GarrettCom .
CSG14 Series Gigabit Converter Switch Input current: Installation and User Guide (12/08) 0.8 amp.(12V DC) 0.4 amp max.(24V DC) 0.2 amp max.(-48V DC) Power Consumption: 4 watts typical, 5 watts max. 3.7 CSG14 Series, DC-powered, -48, 24 and 12VDC Installation This section describes the proper connection of the -48VDC leads (or 24VDC, 12VDC leads) to the DC power terminal block on the Magnum CSG14H hardened media converter (as shown in Figure).
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) equipped with three (3) screw-down lead posts. The power terminals are identified as positive (+) and negative (-), and they are floating inside the unit so that the user if desired may ground either of the terminals. The chassis is “earth” or ground (GND). The connection procedure is straightforward. Simply insert the DC leads to the CSG14H’s power terminals, positive (+) and negative (-) screws.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 3.8 Connecting Ethernet Media The Magnum CSG14 Series Converter Switch can be connected to two media types i.e. fiber and copper (RJ-45) types, run at 1000BASE-T, 100BASE-TX, 10BASE-T and 1000BASE-SX/LX/ZX, 100BASE-FX, or 10BASE-FL. CAT 5E cables should be used when making 1000BASE-T connections. When the ports are used as 10BASE-T ports, CAT 3 may be used.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Fiber (Multi-mode) 100BASE-FX SC Fiber (Single-mode) 100BASE-FX SC, LC Fiber (Multi-mode, Single-mode) 1000BASE-SX SC, LC Fiber (Single-mode) 1000BASE-LX/ZX LC NOTE : It is recommended that high quality CAT 5E or CAT 6 cables (which work for 10Mbps, 100Mbps and 1000Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network, since CSG14 Series switch ports are autosensing for either 10,100 or 1000Mbps.
CSG14 Series Gigabit Converter Switch 1. 2. 3. 4. 3.8.2 Installation and User Guide (12/08) Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used. Connect the other end of the cable to the corresponding device.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 3.8.3 Connecting Fiber Optic SC-type, "Snap-In" The following procedure applies to installations using SC-type fiber connectors, i.e., using multi-mode SC. While connecting fiber media to SC connectors, simply snap on the two square male connectors into the SC female jacks of the Fiber connector until it clicks and secures. 3.8.
CSG14 Series Gigabit Converter Switch 3.8.6 Installation and User Guide (12/08) Power Budget Calculations for CSG14 Series, Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget.
CSG14 Series Gigabit Converter Switch Fiber Port Module CSG14SX Speed, Std. Mode Installation and User Guide (12/08) Std. km Wavel Cable X’mitr R’cvr Worst Worst* typical typical* fdx ength Size Output Sens. OPB, distance OPB, distance (hdx) nm dB Km, fdx μm PT , dB PR ,dB dB Km, fdx 1000Mb Multimode 0.55 SX 850 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4 1000Mb Single -mode LX 10 1310 9/125 -9.5 -20 8.5 17 10.5 21 CSG14LX25 1000Mb Single -mode LX 25 1310 9/125 -4.0 -21 15 37.5 17.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) * Note: The use of either multi-mode or single-mode fiber to operate at 1000Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following factors are both applied: • The 1000Mb fiber segment must operate in full-duplex (FDX) mode, and • The worst-case OPB of the fiber link must be greater than the fiber cable’s passive Attenuation.
CSG14 Series Gigabit Converter Switch 4.0 Installation and User Guide (12/08) OPERATION 4.1 Triple-Speed Functionality, and Switching The Magnum CSG14 Series Converter Switches provide three switched ports. The architecture supports a triple speed-switching environment, with standard autonegotiation capability. The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and speed, and auto cross for plug polarity. (See Section 2.2).
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Switching, Filtering and Forwarding Each time a packet arrives on one of the switched ports, the decision is taken to either filter or to forward the packet. Packets whose source and destination addresses lie on the same port segment, will be filtered, constraining them to one port and relieving the rest of the network from processing them.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) switch automatically keeps up with node locations. An address-aging algorithm causes least-used addresses to fall out in favor of new frequently used addresses. To reset the address buffer, cycle power down-and-up. 4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing The RJ-45 ports support auto cross (MDI or MDIX) in the auto-negotiation mode according to the IEEE 802.3z standard.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) device at the other end of the cable should similarly advertise / respond. Both sides will agree to the speed and mode to be used per the IEEE 802.3z standard. Depending upon the devices connected, this will result in agreement to operate at 10Mbps, 100Mbps or 1000Mbps speed, and full- or half-duplex mode. 4.3 Dual LEDs, Top-front and in End with ports LED Description PWR Illuminates GREEN to indicate power applied.
CSG14 Series Gigabit Converter Switch 5.0 Installation and User Guide (12/08) TROUBLESHOOTING All Magnum products are designed to provide reliability and consistently high performance in all network environments. The installation of Magnum CSG14 Series 10/100/1000 Mb/s Switches is a straightforward procedure (see INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in Section 4.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual. Also check to make sure that the various components of the network are interoperable. 2.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) not the problem is corrected. If not, go to Step 5 below. If the problem is corrected, the Magnum CSG14 Series Switch and its associated cables are functioning properly. If the problem continues after completing Step 4 above, contact your supplier of the Magnum CSG14 Series 10/100/1000 Mb/s Switch unit or if unknown, contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for assistance. 5. 5.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 2. An accurate list of GarrettCom product model(s)involved, with serial number(s). Include the date(s) that you purchased the products from your supplier. 3. It is useful to include other network equipment models and related hardware, including convenient computers, workstations, terminals and printers; plus, the various network media types being used. 4.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization (RMA) number. To obtain an RMA number, please use this URL https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form. Please have the following information readily available: Name and phone number of your contact person.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if GarrettCom cannot duplicate the problem or condition causing the return, the unit will be returned as: No Problem Found.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) 5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection. (You may retain all connectors and this Installation Guide.
CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom.