- Gas Fired Products Inc. Infrared Gas Heater Installation and Operation Instructions

Form #43343530
July 08 –29–
* Available as Accessories
KEY DIMENSIONS AND COMPONENTS OF THE GAS CONNECTIONS
14 to 17
(36 to 43cm)
Approved
Flexible Connector
*Second Stage Regulator with
Vent Leak Limiter to reduce the
Supply Pressure below 14 W.C.
Gas Pressure
= 2 PSIG
Gas Supply
Piping
Sediment Trap
(Drip Leg)
*Manual Gas
Shut Off Valve
Burner Movement
2 (5cm) Max.
Displacement
END VIEW
RECOMMENDED GAS CONNECTION POSITIONS WITH 36 FLEXIBLE GAS HOSE
Adaptor 1/2 NPT female
Gas pipe work must not restrict
opening of hinged service doors.
7 5/8
Alternate Positions
6
SIDE VIEW
Adaptor 1/2 NPT male
Burner Movement
DO NOT install gas connector
vertically if fresh air is to be
connected.
Minimum 1 (25cm)
3 7/8 (10cm)
Certified connectors are recommended to be installed as shown, in one plane, and without sharp bends, kinks or
twists.
INCORRECT POSITIONS
Movement
WRONG
Movement
WRONG
Movement
WRONG
Movement
WRONG