FLASHSHIELD™/ FLASHSHIELD+™ FLEXIBLE
GAS PIPING TRAINING PROGRAM TEST
ADMINISTERED ONLY AFTER COMPLETION OF AUTHORIZED FLASHSHIELD™ TRAINING COURSE.
Circle the appropriate answer.
(ONLINE SECTIONS 1 & 2)
1) FlashShield™ CSST must be installed by a qualified
installer who has successfully completed the
FlashShield™ certification program.
True False
2) e Jacket Stripping Tool is recommended to achieve
the necessary end preparation of the original multi-
layer jacketed FlashShield™ CSST, but it is not
necessary when working with FlashShield
+™ CSST.
True False
3) Gastite recommends review of gastite.com for
information and updates approximately ____.
a) Never
b) Yearly
c) Every 10 years
4) In the event of a conflict between the FlashShield™
Installation Guide and the local code the more
stringent requirement will take precedence.
True False
5) FlashShield™ CSST is approved for use at pressures
up to ____ PSI.
a) 5
b) 15
c) 25
6) FlashShield™ is approved for both natural gas and
propane.
True False
(ONLINE SECTION 3)
7) Starting pressure, appliance input demands (pressure
and CFH), and length of run/longest run information
are all required to size gas piping systems.
True False
8) e longest run is the length of piping from the gas
source to the most remote appliance served by that gas
pressure source.
True False
9) Dual pressure systems will require the use of 2
separate sizing tables; one for the elevated pressure side
of the regulator and one for the low pressure side of
the regulator.
True False
10) Sizing tables can be found;
a) Within the FlashShield™ Installation Guide
b) On the Website
c) On the Gastite Mobile App
d) All of the Above
(ONLINE SECTION 4)
11)
Clearance holes for routing FlashShield
are to be
approximately ____ greater than the O.D. of the tubing.
a) ½
b) ¾
c) 1
12) FlashShield™ can be directly buried in the ground.
True False
13) FlashShield™ can be directly connected to a
moveable appliance.
True False
14) FlashShield™ shall not touch any portion of the
metallic cabinet of a fireplace which utilizes a metallic
vent that penetrates through or above the roof line.
True False
15) Only strike plates provided by Gastite may be used to
protect FlashShield™ CSST.
True False
16) ere are no additional bonding requirements for
FlashShield™ required by the manufacturer; however,
FlashShield™ is to be bonded in the same manner as
rigid metal piping.
True False