Install Instructions

GASTITE DIVISION, TITEFLEX CORPORATION / 1116 Vaughn Parkway / Portland, TN 37148
800.662.0208 / www.gastite.com / gastite@gastite.com
59
SECTION 4: INSTALLATION PRACTICES / JANUARY 2019
a) Pad Mounted Equipment (Fig. 4-68) — Moveable gas appliances
on concrete pads or blocks, such as heat pumps, air conditioners,
pool heaters and NGV refueling systems, shall be connected to the
FlashShield™ CSST system at a termination fitting using either rigid
pipe or an approved outdoor appliance connector.
b) Gas Packs and Other Non-Moveable Equipment (Fig. 4-69) —
Can be connected to the FlashShield™ CSST system either through
a terminating fitting and rigid pipe or directly with FlashShield™
CSST connected to the appliance shut-off valve.
c) Gas Lamps — Permanently mounted lights located on decks
shall be connected to the FlashShield™ CSST system in the same
fashion as permanently mounted grills as shown in the figure and in
accordance with the manufacturers instructions.
d) Yard Mounted Lights — Shall be connected to the FlashShield™
CSST system as shown in Figure 4-70. All FlashShield™ CSST
installed below grade shall be installed in accordance with Section
4.9.
Fig.4-67
Fig. 4-66
Fig. 4-70
Fig.4-68
Fig. 4-69