Double Security Door

202220986-1219
Security Double Door Installation Instructions
Spanish en el reverso
PART DESCRIPTION QTY
A Security Double Door 1
AA 4 inch one-way screws 9
BB Top Bar 1
CC One-way tool 1
DD Cane-Bolt kit 1
EE End Cap 2
NOTE: All parts not shown at actual size. Handle set and lock bolt
sold seperately.
AA
BB
DD
CC
AA
BB
DD
CC
AA
BB
DD
CC
DD
EE
A
CC
PREPARATION
Tools Recommended for Assembly
Drill 3/16” bit, level or string plumb, and pencil.
IMPORTANT: Read all instructions carefully
before starting installation.
NOTE: One-way screws are non-removeable once installed.
Questions, problems, missing parts?
Before returning to your retailer, call
our customer service department at
1-800-222-3667.
ASSEMBLY INSTRUCTIONS
FIGURE 1
Top Bar
Operating Door Stationary Door
Hinge Bar
(pre-attached)
FIGURE 5
FIGURE 2
FIGURE 3 FIGURE 6
FIGURE 4
1. Identify which side
the operating door is
located on. It can be
on either the left or
right side. Operating
door includes the
handle set lock box
(Fig. 1).
5.With the stationary door in the closed
position, position the operating door
(the one with the locksets installed)
over the remaining opening with the
lock bolt extending and protruding
into the respective holes in the
stationary door (Fig. 5).
Repeat steps 3 and 4 for the
operating door.
2. Attach your choice of locksets
(2-3/8” backset). Fully extend
the lock bolt into the “Locked”
position.
6. Insert end caps in ends of header
(Fig. 6).
Leaving approximately 1/8-in space
above the doors, mount the top bar
at top of door using the one-way tool
and 3 one-way screws.
3. Place the stationary door (the one
without locksets) in front of opening
at desired height, making sure that
the security door is vertical and
plumb. Determine where to drill by
marking through the pre-drilled holes
on the hinge bar with pencil (Fig. 3).
4. Pre-drill holes marked in Step 3.
Using the one-way tool, fasten the
door to the house using three one-
way screws. Tighten the one-way
screws only halfway at this time,
in case repositioning the door is
required later (Fig. 4).
ALL
WELDS ON THIS SIDE
OF THE DOOR NEED TO BE
GROUND FLUSH
1/4
TYP.
NOTE:
ALL DIMENSIONS ARE ±1/16" (1.5mm) unless
otherwise specified.
DOOR MUST CONFORM TO PS-022
1/4
TYP.
LARSON STANDARD TOLERANCE
UNLESS OTHERWISE SPECIFIED
0.000 TO 0.124: ±0.007
0.125 TO 0.499: ±0.010
0.500 TO 0.999: ±0.013
1.000 TO 1.999: ±0.017
2.000 TO 2.999: ±0.020
3.00 AND ABOVE: ±0.025
ANGULAR TOLERANCE: ±2°
LARSON MANUFACTURING CO.
SCALE: 1:10
DATE: 20 NOV 2012
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
918-23 FR DR STATIONARY PANEL - WELD DETAIL
BROOKINGS, SD
PART NUMBER: X
DRAWING NUMBER: 918-23 FRENCH DOOR ASSEMBLY (Sheet 5 of 7)
DRWN BY: DIX
THIS DRAWING AND ALL INFORMATION THERIN IS THE PROPERTY OF LARSON MANUFACTURING AND IS CONFIDENTIAL. IT MUST NOT
BE MADE PUBLIC OR COPIED. THIS DRAWING IS LOANED SUBJECT TO RETURN UPON DEMAND AND SHALL NOT BE USED DIRECTLY IN
ANY WAY DETRIMENTAL TO OUR INTEREST. OUR PRIOR SPECIFIC APPROVAL IS REQUIRED FOR EXPOSURE OF THIS DRAWING TO OTHERS
FOR ANY PURPOSE. ANY CHANGES TO THESE SPECIFICATIONS NEED WRITTEN APPROVAL.
DRAWING NUMBER: 918-23 FRENCH DOOR ASSEMBLY (SHEET 5)
ACCEPTANCE OF MATERIAL WILL BE BASED UPON THIS DOCUMENT ONLY.
BY
DESCRIPTION
DATE
REV
DENOTES CRITICAL DIMENSION

Summary of content (4 pages)