Installation Retrofitting Into Existing Transmitter System
Page: 2-6 888-2604-001 03/08/07
WARNING: Disconnect primary power prior to servicing.
2.5.3.2 Atlas Mobile Transmitter - 2 or More PA Cabinets
When the Atlas Mobile Transmitter has two or more PA cabinets, the feedback signals are
connected as shown in Figure 2-4.
The HPF feedback sample is taken from the high power filter output coupler.
The PA sample is taken from the cabinet combiner output coupler.
If the transmitter system has dual exciters, feedback samples for each exciter are ob-
tained by splitting each sample cable, as shown in Figure 2-4
The feedback signals at the exciter input should be padded to yield 0 dBm at the high-
est expected transmitter output power. The sample input power range is -30 to 0 dBm.
Figure 2-4 Atlas Mobile Transmitter - Dual PA Cabinets - Dual Exciters
PA
PA Cabinet
Output
Coupler
High
Power
Combiner
Coupler
Cabinet
Combiner
Filter
RFU/
Exciter
Switcher
PA Cabinet
Apex FLO
Exciter
Apex FLO
Exciter
2-Way
Splitter
2-Way
Splitter