APEX Exciter Incorporating FLO Technology
Navigating the LCD Display Screens Details of the Exciter Status Screens
Page: 3-16 888-2604-001 03/08/07
WARNING: Disconnect primary power prior to servicing.
3.4.4.5 FLO FPGA, Transport Stream Status, Screen 3/5
FPGA Status3.bmp
Figure 3-14 FLO FPGA, Transport Stream Status Screen 3/5
The parameters of the Transport Stream Status screen are as follows.
TS1 Detect: Yes or No TS2 Detect: Yes or No
Yes = transport stream present, No (in red) = transport stream missing
TS1 LOF: Yes or No TS2 LOF: Yes or No
Yes (in red) = fault, No = TSI LOF is OK
TS1 OOF: Yes or No TS2 OOF: Yes or No
Yes (in red) = fault, No = TSI OOF is OK
TS1 OOF Ct: Integer Decimal TS2 OOF Ct: Integer Decimal
TS1 Pkt Rt: Integer Decimal TS2 Pkt Rt: Integer Decimal
WPID Pkt Rt: Decimal SSF Missing: Yes or No
Yes (in red) = SSF missing, No = SSF OK
LPID Pkt Rt: Decimal SSF Multiple: Yes or No
Yes (in red) = SSF multiple, No = SSF OK