60
Model
Reex 75T
MkII BF NG
Reex 75T
MkII BF LPG
Fuel
Space Heating Emissions (NOx) - mg / kWh
input
(GCV) 130 130
Heat
Output
Nominal Heat Output - P
nom
8.3kW 8.3kW
Minimum Heat Output (indicative) -P
min
2.8kW 3.0kW
Auxiliary
Electricity
Consumption
At Nominal Heat Output - el
max
0.003kW 0.003kW
At Minimum Heat Output - el
min
0.003kW 0.003kW
In Standby Mode - el
sb
0.003kW 0.003kW
Useful
Efciency
(NCV)
Useful Efciency at nominal heat output - η
th,nom
92.0% 92.0%
Useful Efciency at minimum heat output (indicative) - η
th,min
75.0% 76.0%
Permanent
Pilot Flame
Power
requirement
Permanent Pilot Flame Power requirement (if applicable) - P
pilot
N/A N/A
Type of heat output/room temperature control
Electronic room temperature control + day timer Yes Yes
Other control options (multiple selections possible)
Room temperature control, with presence detection No No
Room temperature control, with open window detection No No
With distance control option No No
With adaptive start control No No
With working time limitation No No
With black bulb sensor No No
Energy Efciency Index 88.8% 88.8%
Energy Efciency Class A A
Contact: Gazco Ltd, Osprey Road, Sowton Industrial Estate, Exeter, EX2 7JG