Logic HE Range Conventional Flue Log Effect Installation User Instructions
14
Installation Instructions
Model
Gas
CAT.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
Logic HE
CF Log
Remote
I
2H
Natural Gas G20 20mbar 2 x 6.5mm 170 0.476 5.0 2.6
GB, IE
I
3P
Propane G31 37mbar - 150 0.192 5.1 2.6
Logic HE
CF Log
Slide
I
2H
Natural Gas G20 20mbar 2 x 6.5mm 170 0.495 5.2 2.5
GB, IE
I
3P
Propane G31 37mbar - 150 0.192 5.1 2.5
Efciency 84% Net (Class 1)
NO
x
Class 5
Min Flue Size - 5" Diameter
Minimum Flue Specication = T250/N2/0/D/1
Gas Inlet - 8mm
Technical Specification
Covering the following models:
The net efficiency of this appliance has been measured as specified in BS7977-1:2009 and the result after conversion to
gross using the appropriate factor from Table E4 of SAP 2012 is 75.8%. The gross efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
PACKING CHECKLIST
Qty Description Fixing Kit containing:
Log Version
1 x Log Set
1 x Lava Rock
1 x Instruction Manual
1 x Embaglow
4 x Wood Screw
1 x Cable Retention Kit
1 x 1.7m Silicone Seal
4 x Steel Expansion Plug
4 x Eye Bolts
1x 9v Battery (Slide Only)
5 x AA Battery (Remote Only)
Gas Type
LoGic He cf
Remote Control Slide Control
Nat Gas 101-302 101-245
LpG 101-720 101-482