Logic HE Range Conventional Flue Log Effect Installation User Instructions

25
Installation Instructions
7.6 Log D ts onto the locating pin and rests on Log B, see
Diagram 28.
28
D
7.7 Position the 2 embers in the front right and back left corners,
see Diagram 29.
29
7.8 Sparingly spread an amount of the Embaglow bres provided
on the sections highlighted, see Diagram 30.
Take care not to use more than half a packet per
application.
WARNING - DO NOT PLACE NEAR THE PILOT AREA.
30
8. Fitting the Glass Frame
8.1 Ensure that the rope seal on the box is intact, then locate
the glass frame location tabs into the slots on the firebox,
see Diagram 31, Detail A.
8.2 Secure the glass frame using 4 screws in the retaining
bracket, see Diagram 31.
Replace ALL of the glass frame securing screws ensuring
that a screw is present in all fixing slots.
Detail A
A
31
NEVER OPERATE THE APPLIANCE WHEN THE GLASS
FRAME IS REMOVED OR BROKEN.
Refer to the separate decorative front Instructions to replace
the front on the appliance.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
FRAME RETAINING SCREWS ARE LOOSE OR
MISSING.
Operating the Appliance
There are 2 types of control systems available for this
appliance:
Section 9 Manual and Remote Control
Section 10. Slide Control
Follow the relevant section for specific operation.
9. Manual and Remote Control
There are two ways of lighting the appliance:
9a. Using the Manual Controls on the Control Box (located
on the appliance.
9b. By thermostatic remote control.