Reflex 105 Balanced Flue Installation Instructions
39
CONTROL BOX
To replace the Control Box first remove the Main Control Assembly.
Cut the cable tie holding the Ignition lead and the Thermocurrent
cables.
Disconnect the Module and Solenoid leads from the Control Box.
Wi-Fi Lead (if fitted)
Solenoid
Lead
Module
Lead
8-way Cable
1
If fitted disconnect the Wi-Fi Lead.
Note: The Wi-Fi lead is loose when removed, ensure the lead is
not misplaced whilst servicing.
Remove the Ignition Lead. The Control Box is held on by Velcro
pads.
Remove the 2 screws to remove the 2 Interrupter Leads.
Remove the 8 way cable from the Control Box.
8 Way
Cable
Interrupter Leads
Ignition lead
LED Lead
Module
Lead
Solenoid
Lead
Thermocouple
Pilot Pipe
Control
Box
Module
Solenoid
2
Replace in reverse order.
After replacing the Control Box ensure that all cable ties and
connections are refitted.
After replacing the Control Box you will need to reprogram the
handset.
— Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
— Release the reset button and within 20 seconds:
— Press the DOWN button on the handset until you hear
two additional short signals confirming the new code is
set. If there is a single long signal the code learning
sequence has failed or the wiring is incorrect.
Note: When pressing the DOWN button on the handset if two
beeps are not heard:
— Release the DOWN button and CONN will be displayed
on the handset screen. An 8 second count will start on the
handset screen followed by two short beeps conrming
the new code is set. If there is a single long signal the
code learning sequence has failed or the wiring is
incorrect.
FUEL BED INJECTORS
This appliance has 8 Fuel Bed Injectors.
NOTE: The injectors are not identical.
TO ENSURE CORRECT ASSEMBLY REPLACE EACH
INJECTOR INDIVIDUALLY.
Remove the Log Burners and Mesh Tray.
Remove the 2 nuts and lock washers from each Burner Bracket.
1
Remove the Brackets.
Remove the Gasket.
2
Undo the Injectors individually.
SERVICING INSTRUCTIONS