Reflex 105 Balanced Flue Installation Instructions

4
INSTALLATION
APPLIANCE LOCATION
This appliance must not be installed in a room that contains a bath or shower.
Combustible parts of the studwork must not be any closer than the minimum dimensions shown in the diagrams. NOTE: These dimensions
must be maintained even if the combustible materials is protected by non-combustible linings.
Do not pack the void around or above the appliance with insulation materials such as mineral wool.
Ventilation
The void into which the cassette is tted must be ventilated to prevent a build up of heat. If the void is sealed then it will be necessary to t vents
at both low and high levels of both sides with a cut size of 300cm
2
each. These vents should take cold air from the room and return warm air
back into the room.
Gazco recommend using DuctStore W100 Linear Bar Grille vents or equivalent (available online).
DO NOT USE PLASTIC VENTS.
A removable access hatch must be left in the side of the chimney breast for future servicing and inspection of the appliance.
Build the studwork chimney breast to the desired size. Ensure that the clearances to combustible materials is maintained.
SAFETY PRECAUTIONS
For your own and other’s safety, you must install this appliance according to local and national codes of practice. Failure to install the appliance
correctly could lead to prosecution. Read these instructions before installing and using this appliance.
These instructions must be left intact with the user.
Do not attempt to burn rubbish on this appliance.
Keep all plastic bags away from young children.
Do not place any object on or near to the appliance and allow adequate clearance above the appliance.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE
APPLIANCE.
The appliance is tted with an oxygen sensitive pilot that will act to cut off the gas supply to the appliance in the event of incorrect operation of
the ue.
If the system acts to shut off the gas supply, this indicates that there is insufcient ue pull. Continued operation of this safety device means
that there may be a serious problem with the ue system, and this should be inspected by a qualied gas engineer.
Do not use the appliance until an engineer says it is safe to do so.
The oxygen sensitive pilot must not be tampered with. Use only genuine Gazco replacement parts when servicing the appliance - refer to
Servicing section.
IMPORTANT: REFER TO DATA BADGE AND TECHNICAL SPECIFICATION AT THE FRONT OF THE MANUAL TO ENSURE
THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF
USE.
FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SERVICING SECTION REPLACING PARTS.
UNPACKING
Remove the appliance from its packaging, and check that it is complete and undamaged.
Put the loose ceramic parts to one side so that they are not damaged during installation.
INSTALLATION INSTRUCTIONS