Reflex 105 Balanced Flue Installation Instructions

40
3
Replace with the correct size Injector.
See table on Page 12.
NOTE: DO NOT OVERTIGHTEN.
Use thread sealant Loctite 572 when replacing Injectors.
Repeat for the remaining Injectors.
Check for leaks.
LATCHING SOLENOID
Remove the Main Control Assembly.
Remove the cradle holding the rear LED's to access the pipe work
for the solenoid.
Undo the 3 nuts shown and free the solenoid from the pipe work.
A
(Beneath Lip)
1
Remove the Solenoid plug from the Control Box, Arrow A.
Cut the cable tie. NOTE the orientation of the cables.
Replace in reverse order.
Check for leaks.
Ensure that the cable ties are replaced.
CHANGING BETWEEN GAS TYPES
In order to change between gas types, it will be necessary to
change the following components:
Pilot Injector
Main Injectors x 8
Cross lighting Injector
Gas Valve
Main Burner x 4
Contact your Gazco retailer for further information.
A kit of parts is available for this. Always quote the Model number
and Serial number when ordering any spare parts.
BAFFLE
The Bafe must be removed before the Liners can be taken out of
the appliance.
BAFFLE
Undo the 5 screws securing the bafe to the roof of the rebox.
Screws
1
The Bafe can now be removed by lowering the front edge and
pulling forward through the front of the appliance.
TAKE CARE NOT TO DAMAGE THE SIDE PANELS.
When replacing the Bafe ensure that the 3 tabs t into the slots in
the rear liner bracket.
Top View
2
SERVICING INSTRUCTIONS